• Title/Summary/Keyword: Extended chamber

Search Result 67, Processing Time 0.027 seconds

An Acoustic Analysis of Mufflers with a Concentric Extended Pipe (동심 연장관형 소음기의 음향해석)

  • Lee, Jun-Shin;Lee, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.108-114
    • /
    • 1995
  • Cylindrical chamber mufflers with an extended inlet or outlet are extensively used in many application fields to reduce the propagated noise in ducts. The basic attenuation effectivencess in the low frequency region can be explained by the reactive wave action inside the expansion chamber associated with the geometric configurations of the inlet and outlet locations, and the area expansion of the jacket. In this study, an acoustic analysis is carried out for a concentric extended pipe inserted into a simple expansion chamber. An algebraic equation is derived by using the eigenfuction expansion and orthogonality principle in which the acoustic pressures and particle velocities defined on each subdivided surface are expressed by the separable coordinates. By using the proposed analytical method, transmission losses are predicted for several configurations of the concentric extended systems and they agree very well with experimental results.

  • PDF

Acoustic Characteristics of Mufflers with an Extended Iinlet and Outlet (입출구가 연장된 동심형 소음기의 음향해석)

  • 이준신;김연환;김태룡;이정권
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.536-541
    • /
    • 1998
  • Cylindrical chamber silencers with an extended inlet and outlet are widely used to reduce the propagated noise in ducts in many application fields. In this study, an acoustic analysis is carried out for concentric extended pipes inserted into a simple expansion chambers An algebraic equation is derived by using the eigenfunction expansion and orthogonality principle. Using this analytical method, transmission losses are predicted for several configurations of the concentric extended systems.

  • PDF

A Study on the Combustion Characteristics of Lean Mixture by Radicals Induced Injection in a Constant Volume Combustor (1) (정적연소기에서 라디칼 유도분사를 이용한 희박혼합기의 연소특성에 관한 연구 (1))

  • 박종상;이태원;하종률;정성식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.45-53
    • /
    • 2004
  • An experimental study was carried out to obtain the fundamental data about the effects of radicals induced injection on premixture combustion. A constant volume combustor divided to the sub-chamber and the main chamber was used. The volume of the sub-chamber is set up to occupy less than 1.5% of that of whole combustion chamber. Radial twelve narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in the sub-chamber will derive the simultaneous multi-point ignition in the main chamber. While the equivalence ratio of pre-mixture in the main chamber and the sub-chamber is uniform. We have examined the effects of the sub-chamber volume, the diameter of passage hole, and the equivalence ratio on the combustion characteristics by means of burning pressure measurement and flame visualization. In the case of radical ignition method(RI), the overall turning time including the ignition delay became very short and the maximum burning pressure was slightly increased in comparison with those of the conventional spark ignition method(SI), that is, single chamber combustion without the sub-chamber. The combustible lean limit by RI method is extended to more ER=0.25 than that by SI method. Therefore the decrease of every emission including NOx and the improvement of fuel consumption is anticipated due to lean burn.

Acoustic Characteristics of Mufflers with an Extended Inlet and Outlet (입출구가 연장된 동심형 소음기의 음향해석)

  • 이준신
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.503-509
    • /
    • 2002
  • Cylindrical chamber silencers with an extended inlet and outlet are extensively used in many application fields to reduce the propagated noise in ducts. The basic attenuation effectiveness in the low frequency region can be explained by the reactive wave action inside the expansion chamber associated with the geometric configurations of the inlet and outlet locations, and the area expansion of the jacket. In this study. an acoustic analysis is carried out for a concentric extended pipe inserted into a simple expansion chamber. An algebraic equation is derived by using the eigenfunction expansion and orthogonality principle in which the acoustic pressures and particle velocities defined on each subdivided surface are expressed by the separable coordinates. By using the proposed analytical method, transmission losses are predicted for several configurations of the concentric extended systems and they agree very well with experimental results.

Effects on Combustion Characteristics Induced by Ignition Timing and Shape of Passagehole in a IDI Type Constant Volume Combustion Chamber (IDI형 정적 연소기에서 점화시기 및 연락공의 형상이 연소특성에 미치는 영향)

  • 윤수한;이중순;김현지;박춘근;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.220-231
    • /
    • 1996
  • In this research, we use IDI type constant volume combustion chamber which may make up stratified combustion to construct the design back data of lean-burn engine. Some experiments are conducted by the passagehole angle in the adapter of main chamber and sub-chamber. The effects on the combustion characteristics according to the ignition timing are investigated. The used fuel is methanol prospective for alternative fuel. Fuel is injected under 10.78MPa using solenoid and accumulator. As the results of the experiment, combustion characteristics reveals that ignition timing, passagehole angle and shape greatly effects on. Lean inflammability limit is extended to 0.45 in equivalence ratio.

  • PDF

A Visualization Study on the Effects of Ignition Systems on the Flame Propagation in a Constant Volume Combustion Chamber (가시화를 이용한 정적연소기에서 점화장치가 화염전파에 미치는 영향에 관한 연구)

  • Song, Jeong-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1652-1661
    • /
    • 2000
  • A visualization study using the schlieren method is adopted in an optically-accessible, cylindrical constant volume combustion chamber to identify the mechanism of ignition energy and ignition system interaction in spark ignited, lean gasoline-air mixture. In order to research the effects of ignition system on flame propagation, two kinds of ignition system are designed, and several kinds of spark plugs are tested and evaluated. To control the discharge energy, the dwell time is varied. The initial flame development is quantified in terms of 2-D images which provides information about the projected flame area and development velocity as a function of ignition system and discharge energy. The results show that high ignition energy and extended spark plug gap can shorten the combustion duration in lean mixtures. The material, diameter and configuration of electrodes the flame development by changing the transfer efficiency from electrical energy to chemical energy and discharge energy. However these factors do not affect of flame development as much a ignition energy or extended gap does.

CFD (Computational Fluid Dynamics) Study on Partial-Load Combustion Characteristics of a 4-Step-Grate Wood Pellet Boiler (4단 화격자 목재 펠릿 보일러의 부분부하 연소해석)

  • Ahn, Joon;Jang, Jun Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • A numerical simulation was conducted for the combustion chamber of a 4-step grate-firing boiler for wood pellet fuel. The flame is extended to the exit of combustion chamber, which is reproduced by present numerical method based on a homogeneous reaction model. Flow field from the simulation shows a strong recirculation flow at the upstream corner of the chamber, along which the flame is extended to the exit. These combustion and flow characteristics remain unchanged for partial load operations, which suggest modification of the combustion chamber structure rather than resizing should be effective to improve combustion characteristics. Possible modifications for combustion chamber are suggested such as relocating its exit, increasing the number of grate steps or installing internals such as guide baffles.

An Study on the Optimization of Sub-chamber Geometry in CVC with Sub-chamber (부실을 가진 정적연소기에서 부실형상의 최적화 연구)

  • Park, Jong-Sang;Kang, Byung-Mu;Yeum, Jung-Kuk;Ha, Jong-Yul;Chung, Sung-Sik
    • Journal of ILASS-Korea
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 2005
  • An experimental study was carried out to obtain the fundamental data about the effects of radical ignition on premixture combustion. A CVC(constant volume combustor) divided into the sub-chamber and the main chamber was used. Numerous narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in tile sub-chamber derives the simultaneous multi-point ignition in the main chamber. We have examined the effects of the sub-chamber volume, the diameter and number of passage holes, and the equivalence $ratio({\Phi})$ on the combustion characteristics by means of burning pressure measurement and flame visualization. In a CVC, the overall burning time including the ignition delay became very short and the maximum burning pressure was slightly increased by the radical ignition(RI) method in comparison with those by the conventional spark ignition(SI) method. Combustible lean limit by RI method is extended by ${\Phi}=0.25$ compared with that by SI method. Also, In cases of charging the number and the diameter for the fixed total cross section of the passage holes, combustion period increased significantly at a sub-chamber with a single hole, but those of the other conditions had almost a similar tendency in the sub-chamber with 4 or more holes. regardless of equivalence ratio. Therefore, it was Proved that a critical cross section exists with the number of passage holes.

  • PDF

The Effect of Extended Collision Model on a Spray (확장 충돌 모델이 분무계산에 미치는 영향)

  • 한진희;조상무;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.181-191
    • /
    • 2002
  • Spray calculation has been studied to understand the behavior of the spray in a combustion chamber But the spray dispersion has not been predicted properly in a high velocity injection spray or a wall impaction spray. In this study the extended grazing collision model is applied to improve the problem. The gas phase is modelled by the Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled following the discrete droplet model approach in Lagrangian form. The droplet distributions, penetration, width and gas flows are compared for the cases with or without extended model. The extended collision model makes the results better.

System Design for 20W Portable Fuel Cell (20W급 휴대용 연료전지 시스템 설계)

  • Jee, Young-Seok;Ko, Jeong-Sik;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.161-165
    • /
    • 2007
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells. In addition they can be built as a self/non-reformable system and single/dual chamber system. So We evaluated some types of SOFC theoretically, and compared the results from the fuel and performance efficiency point of view.

  • PDF