• Title/Summary/Keyword: Exposure system

Search Result 2,345, Processing Time 0.03 seconds

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

Worker's exposure assessment of cyclonite in explosive compounds and bomb manufacturing companies (폭약 및 폭탄 제조시 발생하는 시클로나이트의 작업자 노출수준 평가)

  • Jeong, Jee Yeon;Lee, Jee Hyeon;Kim, Eun Young;Lee, Seung Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • Cyclonite is a white powder and is very explosive. It can cause seizures (a problem of the nervous system) in human and animals when large amounts are inhaled or eaten. Research papers for workers exposure assesment of the cyclonite are very a few in the world. A field study was conducted at explosive compounds and bomb manufacturing companies to evaluate workers exposure to cyclonite. The airborne average concentration of cyclonite in explosive compounds manufacturing company was $4.10{\mu}g/m^3$(range: ND - $59.92{\mu}g/m^3$), and that of cyclonite in bomb manufacturing company was $31.49{\mu}g/m^3$(range: ND - $291.41{\mu}g/m^3$). Package process and assembly process in both companies were considered the high potential of exposure to cyclonite. Even though all airborne concentrations of cyclonite were lower than occupational exposure standard (MOEL: $500{\mu}g/m^3$), exposure to cyclonite can also occur through dermal contact during manufacture, handling, and clean-up of cyclonite. So control measures for protecting skin absorption of cyclonite were needed for preventing adverse health effect by cyclonite exposure.

Dermal Exposure Associated with Occupational End Use of Pesticides and the Role of Protective Measures

  • MacFarlane, Ewan;Carey, Renee;Keegel, Tessa;El-Zaemay, Sonia;Fritschi, Lin
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.136-141
    • /
    • 2013
  • Background: Occupational end users of pesticides may experience bodily absorption of the pesticide products they use, risking possible health effects. The purpose of this paper is to provide a guide for researchers, practitioners, and policy makers working in the field of agricultural health or other areas where occupational end use of pesticides and exposure issues are of interest. Methods: This paper characterizes the health effects of pesticide exposure, jobs associated with pesticide use, pesticide-related tasks, absorption of pesticides through the skin, and the use of personal protective equipment (PPE) for reducing exposure. Conclusions: Although international and national efforts to reduce pesticide exposure through regulatory means should continue, it is difficult in the agricultural sector to implement engineering or system controls. It is clear that use of PPE does reduce dermal pesticide exposure but compliance among the majority of occupationally exposed pesticide end users appears to be poor. More research is needed on higher-order controls to reduce pesticide exposure and to understand the reasons for poor compliance with PPE and identify effective training methods.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Existing Population Exposure Assessment Using PM2.5 Concentration and the Geographic Information System (지리정보시스템(GIS) 및 존재인구를 이용한 초미세먼지(PM2.5) 노출평가)

  • Jaemin, Woo;Gihong, Min;Dongjun, Kim;Mansu, Cho;Kyeonghwa, Sung;Jungil, Won;Chaekwan, Lee;Jihun, Shin;Wonho, Yang
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.6
    • /
    • pp.298-305
    • /
    • 2022
  • Background: The concentration of air pollutants as measured by the Air Quality Monitoring System (AQMS) is not an accurate population exposure level since actual human activities and temporal and spatial variability need to be considered. Therefore, to increase the accuracy of exposure assessment, the population should be considered. However, it is difficult to obtain population data due to limitations such as personal information. Objectives: The existing population defined in this study is the number of people in each region's grid. The purpose is to provide a methodology for evaluating exposure to PM2.5 through existing population data provided by the National Geographic Information Institute. Methods: The selected study period was from October 26 to October 28, 2021. Using PM2.5 concentration data measured at the Sensor-based Air Monitoring Station (SAMS) installed in Guro-gu and Wonju-si, the concentration for each grid was estimated by applying inverse distance weights through QGIS version 3.22. Considering the existing population, population-weighted average concentration (PWAC) was calculated and the exposure level of the population was compared by region. Results: The outdoor PM2.5 concentration as measured through the SAMS was high in Wonju-si on all three days. Wonju-si showed an average 22% higher PWAC than Guro-gu. As a result of comparing the PWAC and outdoor PM2.5 concentration by region, the PWAC in Guro-gu was 1~2% higher than the observed value, but it was almost the same. Conversely, observations of Wonju-si were 10.1%, 11.3%, and 8.2% higher than PWAC. Conclusions: It is expected that the Geographic Information System (GIS) method and the existing population will be used to evaluate the exposure level of a population with a narrow activity radius in further research. In addition, based on this study, it is judged that research on exposure to environmental pollutants and risk assessment methods should be expanded.

Human Risk Assessment of Perchloroethylene Considering Multi-media Exposure (다매체 노출을 고려한 Perchloroethylene의 인체위해성평가연구)

  • Seo, Jungkwan;Kim, Taksoo;Jo, Areum;Kim, Pilje;Choi, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.5
    • /
    • pp.397-406
    • /
    • 2014
  • Objectives: Perchloroethylene (PCE) is a volatile chemical widely used as a solvent in the dry-cleaning and textile processing industries. It was evaluated as Group 2 "probably carcinogenic to humans" by the Integrated Risk Information System (IRIS) of the United State Environmental Protection Agency (U.S. EPA) in 2012. In order to provide a scientific basis for establishing risk management measures for chemicals on the national priority substances list, aggregate risk assessment was conducted for PCE, included in the top-10 substances. Methods: We conducted the investigation and monitoring of PCE exposure (e.g., exposure scenario, detection levels, and exposure factors, etc.) and assessed its multi-media (e.g., outdoor air, indoor air, and ground water) exposure risk with a deterministic and probabilistic approach. Results: In human risk assessment (HRA), the level of human exposure was higher in the younger age group. The exposure level through inhalation at home was the highest among the exposure routes. Outdoor air or uptake of drinking water represented less than 1% of total contributions to PCE exposure. These findings suggested that the level of risk was negligible since the Hazard Index (HI) induced by HRA was below one among all age groups, with a maximum HI value of 0.17 when reasonable maximum exposure was applied. Conclusion: In conclusion, it was suggested that despite low exposure risk, further studies are needed considering main sources, including occupational exposure.

Development of a Smartphone based Photo-realistic Virtual Reality Exposure Therapy System (스마트폰을 이용한 사진 기반 가상 현실 노출 치료 시스템 개발 및 시험적 적용)

  • Park, Jonghyeon;Park, Jin-young;Kim, Kwanguk Kenny
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.3
    • /
    • pp.75-87
    • /
    • 2016
  • Virtual reality exposure therapy (VRET) has been used for a several decades. However, we are not aware any studies that used a smart-phone based virtual reality techniques. In this study, we suggested a new smart-phone based VRET that included photorealistic techniques. We also evaluated the current system with 32 healthy participants, and results suggested that the current system evoked different emotional valences in indoor/outdoor and familiar/unfamiliar environments. The meaning of current results and potential applications of VRET were discussed.

Status and Prospects of the Korean National Environmental Health Survey (KoNEHS) (국민환경보건기초조사의 현황 및 전망)

  • Park, Choonghee;Yu, Seung Do
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Objectives: The purpose of this review is to suggest future directions for the Korean Environmental Health Survey (KoNEHS) in terms of an environmental health monitoring system and recent environmental health issues in Korea. Methods: The national scale biomonitoring program and environmental health researches which conducted by Ministry of Environment was reviewed for this study. The scope, contents and utilization of results of KoNEHS as a biomonitoring program and other basic function for environmental health monitoring was analyzed. Results: Biomonitoring survey was conducted for basic functions, such as evaluating exposure levels of environmental chemicals and analyzing exposure factors. In order to expand the basic purposes of KoNEHS, the biomonitoring function should be strengthened by enlarging the range of chemicals analyzed and including all age groups in the biomonitoring and health status monitoring functions by using official health-care and mortality data. Exposure factors such as time-activity patterns and micro-environmental pollution levels were studied. The data from the environmental health study were established into a standardized database system for supporting environmental health policy. A definition and concept of environmental health services should be established. Conclusion: To achieve the aims of environmental health, changes in environmental health status and related factors must be observed and predicted reflecting real conditions. In this regard, improving the methodology and system through diverse approaches is necessary for KoNEHS.

Development of Proximity Exposure System with Vertical Structure for Plasama Display Panel (PDP용 수직형 구조의 근접 노광장치 개발)

  • Park, Jeong-Gyu;Jeong, Su-Hwa;Lee, Hang-Bu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2371-2380
    • /
    • 2000
  • In this paper, we developed the proximity exposure system with the vertical structure of glass and mask stage to minimize the mask's warp caused by the pull of gravity. This system, which canirradiate the ultra violet through 1440 H 850 $\textrm{mm}^2$ and 1330X 1015 $\textrm{mm}^2$ exposure area, has the followingcharacteristics. The glass stage can be inclined by 80 degrees at vertical structure to load substrate withsafety on it. When the glass stage is the vertical state, the gap control, alignment control and exposureof ultra violet are executed. So, it enhances the pattern uniformity by minimizing the mask's warp. Theglass stage can also control the gap between the mask and the substrate by the coarse and fine motioncontrol. The mask stage can adjust the posture of photomask to the position of substrate by imageprecessing method. The galss stage for the gap control and the mask stage for the alignment aredesigned independently for each function.

The Research of Railway Noise through Auditory Experiments Focused on the Autonomic Nervous System and Cardiovascular System (청감실험을 통한 철도소음의 자율신경 및 심혈관계통 영향도 연구)

  • Lee, Jae Kwan;Yoon, Eun Sun;Jang, Chae Mi;Jae, Sae Young;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.674-679
    • /
    • 2016
  • According to the conventional studies on the noise and cardiovascular effect, railway noise is better associated with hypertension and adverse cardiovascular events than road traffic noise. But the underlying mechanisms remain unclear. We investigated the hypothesis that exposure to acute railway noise would the unfavorable effect of cardiovascular and autonomic system in healthy young subjects. Using a randomized, sham-controlled cross-over design, ten subjects were assigned to receive either an exposure to high speed train noise (84 dB) for 30 minutes or a control condition (non noise), separated by two days. Blood pressure, heart rate, augmentation index and heart rate variability as indices of cardiovascular and autonomic system function were measured at baseline, during, and recovery from two trials. The results show that exposure to acute railway noise significantly increased diastolic blood pressure and augmentation index, which may cause of adverse cardiovascular effects.