• Title/Summary/Keyword: Exposure fire

Search Result 266, Processing Time 0.032 seconds

Effect of pozzolans on mechanical behavior of recycled refractory brick concrete in fire

  • Nematzadeh, Mahdi;Baradaran-Nasiri, Ardalan;Hosseini, Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.339-354
    • /
    • 2019
  • Reusing building materials and concrete of old buildings can be a promising strategy for sustained development. In buildings, the performance of materials under elevated temperatures is of particular interest for determining fire resistance. In this study, the effect of pozzolan and aggregate type on properties of concrete exposed to fire was investigated. In doing so, nanosilica with cement-replacement levels of 0, 2, and 4% as well as silica fume and ultrafine fly ash with cement-replacement levels of 0, 7.5, and 15% were used to study effect of pozzolan type, and recycled refractory brick (RRB) fine aggregate replacing natural fine aggregate by 0 and 100% was utilized to explore effect of aggregate type. A total of 126 cubic concrete specimens were manufactured and then investigated in terms of compressive strength, ultrasonic pulse velocity, and weight loss at $23^{\circ}C$ and immediately after exposure to 400 and $800^{\circ}C$. Results show that replacing 100% of natural fine aggregate with recycled refectory brick fine aggregate in the concretes exposed to heat was desirable, in that it led to a mean compressive strength increase of above 25% at $800^{\circ}C$. In general, among the pozzolans used here, silica fume demonstrated the best performance in terms of retaining the compressive strength of heated concretes. The higher replacement level of silica fume and ultrafine fly ash pozzolans in the mixes containing RRB fine aggregate led to a greater weight loss rate, while the higher replacement level of nanosilica reduced the weight loss rate.

Analytical post-heating behavior of concrete-filled steel tubular columns containing tire rubber

  • Karimi, Amirhossein;Nematzadeh, Mahdi;Mohammad-Ebrahimzadeh-Sepasgozar, Saleh
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.467-482
    • /
    • 2020
  • This research focused on analyzing the post-fire behavior of high-performance concrete-filled steel tube (CFST) columns, with the concrete containing tire rubber and steel fibers, under axial compressive loading. The finite element (FE) modeling of such heated columns containing recycled aggregate is a branch of this field which has not received the proper attention of researchers. Better understanding the post-fire behavior of these columns by measuring their residual strength and deformation is critical for achieving the minimum repair level required for structures damaged in the fire. Therefore, to develop this model, 19 groups of confined and unconfined specimens with the variables including the volume ratio of steel fibers, tire rubber content, diameter-to-thickness (D/t) ratio of the steel tube, and exposure temperature were considered. The ABAQUS software was employed to model the tested specimens so that the accurate behavior of the FE-modeled specimens could be examined under test conditions. To achieve desirable results for the modeling of the specimens, in addition to the novel procedure described in this research, the modified versions of models presented by previous researchers were also utilized. After the completion of modeling, the load-axial strain and load-lateral strain relationships, ultimate strength, and failure mode of the modeled CFST specimens were evaluated against the test data, through which the satisfactory accuracy of this modeling procedure was established. Afterward, using a parametric study, the effect of factors such as the concrete core strength at different temperatures and the D/t ratio on the behavior of the CFST columns was explored. Finally, the compressive strength values obtained from the FE model were compared with the corresponding values predicted by various codes, the results of which indicated that most codes were conservative in terms of these predictions.

Firefighters' Exposures to Polynuclear Aromatic Hydrocarbons and Volatile Organic Compounds by Tasks in Some Fire Scenes in Korea (일부 화재현장에서 소방공무원의 직무별 다핵방향족탄화수소 및 휘발성유기화합물 노출평가)

  • Jin, Suhyun;Byun, Hyaejeong;Kang, Taesun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.477-487
    • /
    • 2019
  • Objectives: Firefighters are known to be exposed to a variety of toxic substances, but little information is available on the exposure profile of firefighting activities. The aims of this study were to conduct exposure monitoring of toxic chemicals at fire scenes, to compare the concentrations of respective chemicals among firefighting tasks, and to assess the main factors influencing the concentrations of chemicals. Methods: Researchers performed sampling at firefighting scenes during four weeks in 2013. At the scene, we collected samples based on firefighters' own activities and examined the situation and scale of the accident. Collected samples were classified into three categories, including fire extinguishing and overhaul, and were analyzed in the laboratory according to respective analysis methods. Results: A total of fourteen fire activity events were surveyed: five fire extinguishing, six overhaul, and three fire investigations. Although no substance exceeded the ACGIH TLV, PAHs were detected in every sample. Naphthalene ranged from 0.24 to 279.13 mg/㎥ (median 49.6 mg/㎥) and benzo(a)pyrene was detected in one overhaul case at 10.85 ㎍/㎥. Benzene (0.01-12.2 ppm) was detected in every task and exceeded the ACGIH TLV. No significant difference in concentrations between tasks was shown. Conclusions: These results indicate that all firefighting tasks generated various hazardous combustion products, including possible carcinogens.

Inhibitory Effects of Aureobasidium pullulans MHAU2101 Isolated from Domestic Pear Blossom Against Fire Blight (국내 배나무 꽃에서 분리한 Aureobasidium pullulans MHAU2101의 화상병 발생 억제 효과)

  • Hyeonseok Oh;Hyo-Won Choi;Yong Hwan Lee;Seung Yeup Lee;Mi-Hyun Lee;Sang-Keun Oh
    • The Korean Journal of Mycology
    • /
    • v.50 no.4
    • /
    • pp.331-341
    • /
    • 2022
  • This study was conducted to identify yeast species isolated from domestic pear blossom through gene sequencing and analysis of morphological characteristics, and to confirm specific yeast species inhibitory effects toward fire blight in immature apples, pears, and crab apple blossoms. Yeast morphological characteristics were consistent with the known characteristics of Aureobasidium pullulans. Nucleotide sequencing of the D1/D2 region of large-subunit (LSU) 26S ribosomal DNA and the internal transcribed spacer (ITS) region confirmed its identity as A. pullulans (MHAU2101). Inoculation of immature fruits with A. pullulans MHAU2101 before exposure to Erwinia amylovora prevented fire blight symptoms in apples and pears. A. pullulans MHAU2101 treated crab apple blossoms had a significantly lower flower infection rate than untreated blossoms, revealing 64% of the potency of streptomycin. The A. pullulans MHAU2101 treated group also displayed lower E. amylovora density in both pistil and hypanthium compared to the untreated group, especially in the hypanthium. This study confirms that A. pullulans MHAU2101 isolated from domestic pear blossom can effectively suppress the onset of fire blight.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

A Survey on the Risk Perceptions of Employees in Nuclear Power Plants (원자력 발전소 종사자들의 리스크 인식 조사)

  • Lee, Hee Hwan;Park, Dal Jae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.134-139
    • /
    • 2017
  • This study has been performed to investigate the risk perceptions of employees in nuclear power plants. A representative sample of 473 employees was surveyed(about 79% response rate). The questionnaire included scales on both risk perceptions of critical five hazards that could be occurring in the nuclear power plants and two psychometric attitudes. Higher risk perceptions between managers and non-managers to five hazards used in this study were entirely obtained from the managers. It was also found that the perceived higher hazards were in the following order: radiation exposure, radioactive release, explosion, fire and radioactive waste. For the controllability, higher risk perceptions to the all factors were obtained from the managers, and higher ones were non-managers in the dread.

An Experimental Study on the Residual Compressive Strength Characteristics of Concrete Exposed to High Temperature (고온에 노출된 콘크리트의 잔류압축강도특성에 관한 연구)

  • 오병환;한승환;조재열;이성규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.285-290
    • /
    • 1994
  • The influence of elevated temperatures on the mechanical properties of concrete is important for fire-resistance studies and also for understanding the behavior of containment vessel, such as nuclear reactor pressure vessels, during service and ultimate condition. The present study is to clarify the damage/deterioration of concrete structures that are subjected to high temperature exposure. To this end, comprehensive experiments are conducted. The major test variables are the peak temperatures, rate of temperature increase, and sustained duration at peak temperature. The results include weight loss residual compressive strength and stress-strain curve. From those results, residua compressive strength formula and stress-strain relationship are proposed.

  • PDF

An Experimental Study on the Structural Performance of Slab Joint Using Welded Wire Fabric (용접철망을 사용한 슬래브접합부의 구조성능에 관한 실험적 연구)

  • Yoon, Young-Ho;Yang, Ji-Soo;Kim, Suk-Jung;Chung, Lan;Yang, Young-Sung;Chung, Heon-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.291-300
    • /
    • 1994
  • The influence of elevated temperatures on the mechanical properties of concrete is important for fire-resistance studies and also for understanding the behavior of containment vessel, such as nuclear reactor pressure vessels, during service and ultimate condition. The present study is to clarify the damage/deterioration of concrete structures that are subjected to high temperature exposure. To this end, comprehensive experiments are conducted. The major test variables are the peak temperatures, rate of temperature increase, and sustained duration at peak temperature. The results include weight loss residual compressive strength and stress-strain curve. From those results, residua compressive strength formula and stress-strain relationship are proposed.

  • PDF

Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition (전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교)

  • Lee, Jae-Hun;Hwang, Jun-Ho;Kim, Young-Seop;Kim, Hyo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF

Fire Properties of Polypropylene Fiber Reinforced High-Strength Concrete with Pre-loading level (Part 1 Strength properties) (하중조건에 따른 섬유를 혼입한 고강도콘크리트의 내화특성 (1보 압축특성을 중심으로))

  • Kim, Young-Sun;Lee, Tae-Gyu;Lee, Eui-Bae;Park, Gyu-Yeon;Kawabata, Ichizo;Kim, Gyu-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.477-478
    • /
    • 2009
  • The objective of this study is to increase the insight of the mechanical behaviour of high-strength concrete prepared with fiber reinforcement after exposure to elevated temperatures. In particular, the result of the effects of contents of polypropylene fiber and level of preload on the residual compressive strength, load bearing and stress-strain curve of concrete are discussed

  • PDF