• Title/Summary/Keyword: Exposure fire

Search Result 266, Processing Time 0.034 seconds

Consequence Analysis of Toxic Gases Generated by Fire of Lithium Ion Batteries in Electric Vehicles (전기자동차 내 리튬이온전지 화재로 발생하는 독성가스의 위험성 분석)

  • Oh, Eui-young;Min, Dong Seok;Han, Ji Yun;Jung, Seungho;Kang, Tae-sun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2019
  • As the market for portable electronic devices expands, the demand for Lithium Ion Battery (LIB) is also increasing. LIB has higher efficiency than other secondary batteries, but there is a risk of explosion / fire due to thermal runaway reaction. Especially, Electric Vehicles (EV) equipped with a large capacity LIB cell also has a danger due to a large amount of toxic gas generated by a fire. Therefore, it is necessary to analyze the risk of toxic gas generated by EV fire to minimize accident damage. In this study, the flow of toxic gas generated by EV fire was numerically analyzed using Computational Fluid Dynamic. Scenarios were established based on literature data and EV data to confirm the effect distance according to time and exposure standard. The purpose of this study is to analyze the risk of toxic gas caused by EV fire and to help minimize the loss of life and property caused by accidents.

Assessment of Thermal Protection Performance of Firefighting Garments for Hydrogen Jet Fire (수소제트화재에 대한 특수 방화복의 열 방호 성능시험 평가)

  • UNGGI YOON;BYOUNGJIK PARK;YANGKYUN KIM;SUNGWOOK KANG;OHKKUN LIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.3
    • /
    • pp.310-317
    • /
    • 2024
  • In this study, Aimed to develop technology to ensure the safety of firefighters responding to hydrogen incidents and to review the performance of protective super absorbent polymer (SAP) that could help maintain the thermal protection performance of equipment with protective properties. Tests were conducted, including bench-scale and full-scale thermal exposure tests, to review the protective performance of SAP using firefighting garments commonly used by firefighters. The results showed that without SAP application, 2nd degree burn areas were measured at 9.4%, and 3rd degree burn areas at 7.7%. In contrast, when SAP was applied, the percentage of 2nd degree burn areas decreased to 7% on the lower body, and there was no temperature rise causing 3rd degree burns. Therefore, it is expected that by applying SAP to the outer surface of firefighter garments, even under temporarily high temperature conditions such as hydrogen jet flames, thermal damage to firefighters could be protected for a certain period.

Exposure Assessment for Toxic Hepatitis Caused by HCFC-123

  • Kim, Ki-Woong;Park, Hae Dong;Jang, Konghwa;Ro, Jiwon
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.356-359
    • /
    • 2018
  • This case report attempts to present a case of acute toxic hepatitis in fire extinguisher manufacturing workers exposed to 2,2-dichloro-1,1,1-trifluoro-ethane (HCFC-123) in August 2017 in Korea. Twenty-two-year-old male workers were exposed to HCFC-123 for 1.5 hours one day and for 2.5 hours the other day, after which one worker died, and the other recovered after treatment. The workers were diagnosed with acute toxicity of hepatitis. However, exposure levels of HCFC-123 were not known with no work environment measurement done. Therefore, this study was conducted to estimate the exposure concentration of HCFC-123 via a job simulation experiment. In the simulation, the HCFC-123 exposure concentration was measured with the same working practice and working time as with the workers aforementioned. As a result, the workers who infused HCFC-123 into storage tanks were estimated to be exposed to HCFC-123 at a concentration of $20.65{\pm}10.81ppm$, and a mean concentration of area samples within a working radius were estimated as $70.30{\pm}18.10ppm$. Valve assembly workers working on valves of a fire extinguisher filled with HCFC-123 were exposed to HCFC-123 at concentrations of $91.65{\pm}4.03ppm$ and $115.55{\pm}7.28ppm$, respectively, in the simulation, and area samples simulated within the working radius were also found to be high with concentrations of $122.75{\pm}91.15ppm$ and $126.80{\pm}60.25ppm$, respectively. Nitrogen gas packing workers, who did not handle HCFC-123 directly, were exposed to the agent at a concentration of $71.80{\pm}8.49ppm$. These results suggest that exposure to HCFC-123 at high concentrations for 1.5-2.5 hours caused acute toxic hepatitis in two workers.

Experimental Study on the Effects of Combustion Products on the Human Body and Suggestion of Law Revision (흡음재의 연소 생성물이 인체에 미치는 영향에 대한 실험적 연구 및 법률 개정 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.28-34
    • /
    • 2019
  • Regardless of the ignition source, the main factors affecting the spread of flames to the human body are combustibles. The sound absorption material, which is the finishing material used in music institutes and karaoke rooms, consists of polyurethane that generates a large amount of toxic gas with a high amount of combustion gases during a fire. Still, the current law does not require the use of impregnated finishing materials for tutoring services with less than 100 users. In this study, the rate of flame diffusion was measured using the MultiRaelite composite gas measuring instrument (target substance VOC, HCHO, SO2, CO2, CO, HCN, and NO2) for the collection of sound-absorbing materials installed in the actual music academy. The results showed that the toxic gas found in this experiment exceeded the allowable concentration of TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). In addition, a comparative combustion test of the general sound absorber and non-combustion sound absorbing materials on the market showed wide differences in ignition and diffusion. Therefore, based on the results of the experiment, private institutes with less than 100 users should be mandated to use non-combustion sound absorbing materials.

The Flame and Distributed Temperature Restraint Properties of Fire Venetian Blind Louver in Buildings (차양식 방화루버의 화염 및 온도 전파 억제 특성)

  • Chae, Young-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • The purpose of this study is to improve the fire prevention performance using the fire venetian blind louver subjected to burning by fire flame. The investigation is based on testing 2 full scale specimens, which is $3m{\times}3m$ module, $850mm{\times}1,500mm$ open, and $900mm{\times}900mm{\times}175mm$ venetian blind louver. Two louver thickness (1.5 and 2.0mm) were adopted. The specimens were exposed to fire flame temperature levels of ISO834 at the lower surface of the fire venetian blind louver specimens with exposure duration of one hour in Korea Institute of Construction Technology (KICT). It was found from the test results that the values of distributed temperature, decreased for all specimens for protecting to fire flame by venetian blind louver. The results of tests were a good fire prevention performance between in initial to 6 mins. At 60 minutes around ISO 834 fire loading, the percentages of distributed temperature in 500mm and 800mm height ranged between 11 and 10% respectively, regardless of louver thickness. This study, therefore, will improve the fire venetian blind louver for fire protection and prevention performance.

Cement Paste Hardened Body with High Temperature Exposure Time Fourier Transform Infrared Spectroscopy (고온 노출 시간에 따른 시멘트 페이스트 경화체의 푸리에 변환 적외분광 분석)

  • Kim, Min-Hyouck;Cho, Hyeon-Seo;Lee, Gun-cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.120-121
    • /
    • 2019
  • In this study, FT-IR analysis was performed by exposing cement paste to high temperature in order to characterize the change of hydration behavior of concrete structure damaged by fire accident. As the holding time increased, the Al-O vibration region increased due to the increase of Si-O symmetric Ca2(SiO4) and Brownilerite, and the OH stretching region tended to increase due to thermal decomposition of Ca(OH)2.

  • PDF

An Experimental Study on Fire Safety Performance of Glass Wool Sandwich Panel (그라스울 샌드위치패널의 화재 안전 성능에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.21-27
    • /
    • 2012
  • A real A real scale fire test was performed in accordance with KS F ISO 9705 test method to investigate the combustion characteristics of glass wool sandwich panels. To do this, six kinds of specimens having different density and thickness were examined. The glass sandwich panels were installed inside the room, which had internal dimensions of 2.4 m wide${\times}3.6m$ deep${\times}2.4m$ high. also, combustion characteristic are determined through the exposure of specimens to flame by the propane gas burner has a capacity of 100 kW (10 minutes) and 300 kW (10 minutes) for total 25 minutes of test time. Results of the real sale fire test, it was found that maximum HRR of each specimen was 333.2~365.5 kW, maximum heat flux was 12.4~12.9 kW/$m^2$ And, maximum internal temperature for all specimens was not over $500^{\circ}C$. During the real scale fire test, flash-over didn't occur and the difference by density and thickness of specimen was not found from the results of HRR, heat flux, and internal temperature measurement.

Estimating the Automobile Insurance Premium Based on Credibilities (여러가지 신뢰도에 근거한 자동차 보험료 예측)

  • Kim, Yeong-Hwa;Kim, Mi-Jung;Kim, Myung-Joon
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.2
    • /
    • pp.279-292
    • /
    • 2011
  • Credibility theory is one of the most important theories of actuarial science to calculate the proper insurance premium. In this paper, the rule of relative exposure volume, the square root rule, the B$\"{u}$hlmann credibility and B$\"{u}$hlmann-Straub credibility with the basic concept of credibility have been introduced, Also, we estimate new premiums based on these methods for real data. As a result, the rule of relative exposure volume provides the highest accuracy.

Ignition Characteristics and Combustion Gas Analysis of the Plastics Foam (발포 프라스틱의 착화특성 및 연소가스 분석)

  • 이근원;김관응
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.48-52
    • /
    • 2001
  • This study was undertaken to investigate fire risk characteristics of the plastics foam that is used an insulating materials in workplaces. The ignition characteristics and combustion gas of the plastics foam were carried out using the ISO self-Ignition tester, the Cone Calorimeter, and NES combustion analyzer. The experimental materials used were commercial samples and their composition is not disclosed by the manufacturer. As the experimental results, the self-ignition temperature of the plastics foam ranges from $410^{\circ}C$ to $510^{\circ}C$, and the flash-ignition temperature of plastics foam ranges from $370^{\circ}C$ to $450^{\circ}C$. The difference of ignition temperature on density with plastics foam type was smaller since the amount of combustible gas to ignite is not caused enough. The time to ignition of the polyethylene foam in samples of the plastics foam was shorter, and its of polyethylene foam was longer. The concentration of carbon dioxide of the polyethylene foam shows higher in samples of the plastics foam. It is found that the concentration values of carbon monoxide of the plastics foam show very fatality on people during exposure of 30 minutes in fire.

  • PDF

Reliability Assessment of Forest Fire on EHV Polymer Insulator Strings (송전용 폴리머애자의 산불 영향 신뢰성 평가)

  • Min, Byeong-Wook;Shin, Tai-Woo;Choi, In-Hyuk;Choi, Han-Yeol;Park, Jae-Ung;Yu, Kun-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.436-437
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea but polymer insulators which are superior in that they are light weight, explosion proof, impact proof, economical with construction characteristics, have been in use for the 154kV transmission line since 1999 following a worldwide trend towards the reduced weight, simplification and compact usage of new material insulators. However there have been approximately 500 cases of forest fires in Korea, so the transmission lines that for the most part pass through mountainous areas have been highly effected and the highly polymerized compound polymer insulator has raised concern about reliability in cases of exposure to forest fires. Therefore for the reliability assessment of the effect of forest fires on polymer insulators, mechanical and electrical characteristics are analyzed by an artificial flare test device and transmission facility surrounding conditions along with forest fire characteristics are surveyed. In addition to this, actual 90kV energized transmission line was tested with an artificial forest fire and the expanded usage of polymer insulators is presented through the analysis of mechanical and electrical characteristics and physical properties, and a study on the influence of forest fires on polymer insulators.

  • PDF