• Title/Summary/Keyword: Exposure dose calculation

Search Result 76, Processing Time 0.019 seconds

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir

  • Choi, Yoomi;Kim, Hyoungtaek;Kim, Min Chae;Yu, Hyungjoon;Lee, Hyunseok;Lee, Jeong Tae;Lee, Hanjin;Kim, Young-su;Kim, Han Sung;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2599-2605
    • /
    • 2022
  • The Korea Retrospective Dosimetry network (KREDOS) performed an inter-laboratory comparison to confirm the harmonization and reliability of the results of retrospective dosimetry using mobile phone. The mobile phones were exposed to 192Ir while attached to the human phantoms in the field experiment, and the exposure doses read by each laboratory were compared. This paper describes the reference dosimetry performed to present the reference values for inter-comparison and to obtain additional information about the dose distribution. Reference dosimetry included both measurement using LiF:Mg,Cu,Si and calculation via MCNP simulation to allow a comparison of doses obtained with the two different methodologies. When irradiating the phones, LiF elements were attached to the phones and phantoms and irradiated at the same time. The comparison results for the front of the phantoms were in good agreement, with an average relative difference of about 10%, while an average of about 16% relative difference occurred for the back and side of the phantom. The differences were attributed to the different characteristics of the physical and simulated phantoms, such as anatomical structure and constituent materials. Nevertheless, there was about 4% of under-estimation compared to measurements in the overall linear fitting, indicating the calculations were well matched to the measurements.

Clinical Application of 3-D Conformal Radiotherapy for Carcinoma of the Ethmoid Sinus : I. Comparative Analysis Between Conventional 2-D and 3-D Conformal Plans (사골동 종양의 3-차원 입체조형치료 : I. 2차원 치료계획과 3차원 치료계획의 비교분석)

  • Lee Sangwook;Kim Gwi Eon;Keum Ki Chang;Park Hee Chul;Cho Jae Ho;Han Soung Uk;Lee Kang Kyu;Suh Chang Ok;Hong Won Pyo;Park In Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.287-296
    • /
    • 1997
  • Purpose : This is study of whether 3-D conformal radiotherapy for carcino-mas of the ethmoid sinus were better than those treated with conventional 2-D plan, Materials and Methods : The 3-D conformal treatment Plans were compared with conventional 2-D plans in 4 patients with malignancy of the ethmoid sinus. Isodose distribution, dose statistics, and dose volume histogram of the planning target volume were used to evaluate differences between 2-D and 3-D plans. In addition. the risk of radiation exposure of surrounding normal critical organs are evaluated by means of point dose calculation and dose volume histogram. Results : 3-D conformal treatment plans for each patient that the better tumor coverages by the planning target volume with improved dose homo-geneity, compared to 2-D conventional treatment Plans in the same Patient. On the other hand, the radiation dose distributions to the surrounding nor-mal tissue organs, such as the orbit and optic nerves are not significantly reduced with our technique, but a substantial sparing in the brain stem and optic chiasm for each patient. Conclusion : Our findings represented the potential advantage of 3-D treatment planning for dose homogeniety as well as sparing of the normal tissue surrounding the tumor. However, further investigational studies are required to define the clinical benefit.

  • PDF

Uncertainty Management on Human Intrusion Scenario Assessment of the Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste: Comparative Analysis of RESRAD and GENII (중저준위방사성폐기물 표층처분시설의 인간침입 시나리오 평가에 대한 불확실성 관리: RESRAD와 GENII의 비교분석)

  • Kim, Minseong;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.369-380
    • /
    • 2017
  • In order to manage the uncertainty about the evaluation and analysis of the human intrusion scenario of the Gyeongju Low and Intermediate Level Radioactive Waste(LILW) disposal facility, the calculation result by the GENII code was assessed using the RESRAD code, which was developed to evaluate the radiation effects of contaminated soil. The post-drilling scenario was selected as a human intrusion scenario into the near-surface disposal facility to analyze the uncertainty of the modeling by identifying any limitations in the simulation of each code and comparing the evaluation results under the same input data conditions. The results revealed a difference in the migration of some nuclides between the codes, but confirmed that the dose trends at the end of the post-closure control period were similar for all exposure pathways. Based on the results of the dose evaluation predicted by RESRAD, sensitivity analysis on the input factors was performed and major input factors were derived. The uncertainty of the modeling results and the input factors were analyzed and the reliability of the safety evaluation results was confirmed. The results of this study can be applied to the implementation 'Safety Case Program' for the Gyeongju LILW disposal facility.

Determination of Risk Ranking of Combination of Potentially Hazardous Foods and Foodborne Pathogens Using a Risk Ranger (Risk Ranger를 활용한 잠재적 위해식품과 미생물 조합에 대한 위해순위 결정)

  • Min, Kyung-Jin;Hwang, In-Gyun;Lee, Soon-Ho;Cho, Joon-Il;Yoon, Ki-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.91-99
    • /
    • 2011
  • Risk ranking must be determined for various hazards/food combinations to conduct microbial risk management effectively. Risk Ranger is a simple, easy-to-use calculation tool developed in Microsoft Excel and designed to rank the risk (low, medium, and high) for semi-quantitative microbial risk assessment. The user is required to answer 11 questions in Risk Ranger related to 1) severity of the hazard, 2) likelihood of a disease-causing dose of the hazard being present in the meal, and 3) the probability of exposure to the hazard in a defined time. This study determined the risk ranking for twenty three combinations of foodborne pathogens/potentially hazardous foods (PHFs) using a Risk Ranger. In this study, pathogenic E. coli in fresh cut produce salad was scored as 79, which was the highest rank among the 23 combinations of the foodborne pathogens and PHFs. On the other hand, zero risk was obtained with V parahaemolyticus in sushi, Salmonella in meat products and E. coli O157:H7 in hamburger patties. Although Risk Ranger is very simple method to rate the risk of foodborne pathogens and PHFs combination, the accuracy of result was mainly affected by the availability and accuracy of data in the literature. According to the result of literature review, the data are needed for contamination rate of raw materials, consumption amount/frequency of PHFs, and the effect of processing on pathogen. Risk ranking must be continuously revalidated with new data.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF