• Title/Summary/Keyword: Exposure direction

Search Result 273, Processing Time 0.026 seconds

Double Punch Tensile Strength of Cylindrical Mortar with Steel Fibers aligned in Circumferential Direction by Electro-Magnetic Field (전자기장을 이용하여 강섬유를 원주방향으로 배열시킨 원통형 몰탈의 Double Punch 인장강도)

  • Shin, Sun-Chul;Mukharromah, Nur Indah;Moon, Do-Young;Park, Dae-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.40-47
    • /
    • 2022
  • In this study, the direction of the steel fibers mixed in the normal mortar and the steel slag mortar was arranged in the circumferential direction by using an electromagnetic field, and a double punch test was performed to evaluate the effect of magnetic filed exposure on tensile strength and on fracture energy. As a result of the experiment, it was confirmed that it is possible to arrange the steel fibers in the circumferential direction. Tensile strength and displacement at failure were also increased according to the arrangement of steel fibers due to exposure to electromagnetic fields. On the other hand, the fracture energy hardly increased. It is considered that there was a limit in resisting crack growth because the area where the arrangement of steel fibers could be adjusted under the electromagnetic field was not deep to center of specimen and the end shape of the steel fibers were straight not hooked. Additional research is needed to address these issues.

Demographic Characteristics and Exposure Assessment for Applicants Who Have Been Injured by Humidifier Disinfectant - Focusing on 4-1 and 4-2 Applicants - (가습기살균제 피해 신청자들의 인구학적 특성 및 노출평가 - 4-1차와 4-2차 신청자를 중심으로 -)

  • Choi, Yoon-Hyeong;Ryu, Hyeonsu;Yoon, Jeonggyo;Lee, Seula;Kwak, Jung Hyun;Han, Bo-Young;Chu, Yeon-Hee;Kim, Pan-Gyi;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.301-314
    • /
    • 2018
  • Objectives: The aim of this study was to introduce the overall progress of exposure assessment to humidifier disinfectant (HD); to present participants' demographic characteristics, exposure characteristics to humidifier disinfectant, and exposure classification; and furthermore to compare those characteristics between survivors and non-survivors. Methods: An assessment of environmental exposure to HD was conducted using modified HD-specific questionnaires that had been previously validated. We analyzed the data from 4,482 participants who had been potentially exposed to HD and had registered with the KEITI (Korea Environmental Industry & Technology Institute) from September 2016 to May 2018 (the fourth survey). Environmental exposure assessments were performed as follows: 1) contact with participants, 2) environmental exposure assessment though face-to-face interviews, 3) assessment review and coding, and 4) exposure rating. Results: Overall, survivors made up 77.1% (3,457 subjects) and non-survivors made up 22.9% (1,025 subjects). When compared with the survivors, non-survivors had a higher proportion of subjects aged >60 years and subjects who answered as suffering lung damage and having purchased HD because it is "Beneficial to health" (p<0.05). For the exposure characteristics compared to survivors, non-survivors had a higher proportion of cases of distance from humidifier to face being less that one meter and the spray direction being toward the face (p<0.05). Overall, respondents who used the "Oxy Ssak Ssak New Gaseupgi Dangbun", "Aekyung Gaseupgi Mate", "Homeplus Gaseupgi Chungjungje", and "E-Mart Gaseupgi Salgyunje" products made up 66.1, 12.3, 4.0, and 3.6%, respectively, and 72.5% of respondents used products with PHMG as the active chemical. When compared with survivors, non-survivors had a higher proportion of use of "Oxy Ssak Ssak New Gaseupgi Dangbun" but a lower proportion of use of products with CMIT/MIT, PGH, or PHMG as the active chemical. Conclusions: This study provided demographic characteristics and exposure assessment for applicants who have been injured by HD. In spite of the limitations of performing past exposure assessment through a questionnaire survey, such as recall bias, useful results may be obtained by comparing survivors with non-survivors. Further studies such as the exposure rating method and so on are necessary to assess past exposure to HD.

Investigation of Liquid Crystal Alignment on ion beam exposed polystyrene surface (이온빔을 조사한 폴리스타일렌 기판에서의 액정의 배향특성)

  • Hwang, Hyun Suk;Lee, Jong-Deok;Rho, Jungkyu;Han, Jeong-Min
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.1
    • /
    • pp.33-37
    • /
    • 2014
  • This paper introduces homogeneous liquid crystal (LC) orientations on chemically modulated polystyrene (PS) surfaces using various ion beam (IB) exposure time. Transparent PS was replaced with conventional polyimide material. As a non-contact process, IB bombardment process induced LC orientation in the direction parallel to the IB process. Through x-ray photoelectron spectroscopy, it was shown that the chemical compositional changes of the IB-irradiated PS surfaces were determined as a function of IB exposure time.Using this analysis, the optimal IB bombardment condition was determined at IB exposure time of up to 15 s. Moreover, thermal stability on IB-irradiated PS surfaces were carried out which showed that a relatively high IB exposure time induced a thermally stable LC alignment property.

Effects of Combined Environmental Factors on Mechanical and Thermal Analysis Properties of Graphite/Epoxy Composites (복합적인 환경인자가 탄소섬유강화 복합재의 기계적 및 열분석 특성에 미치는 영향)

  • Lee, Sang-Jin;Lee, Jong-Keun;Yoon, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1416-1425
    • /
    • 2002
  • In this study, the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated by the use of an accelerated aging test. Environmental factors such as temperature, moisture. and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile. bending, and shear specimens those are transverse to the fiber direction, and bending specimens those are parallel to the tiber direction - were used to investigate the effects of environmental factors on mechanical properties of the composites. Also, glass transition temperature, storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured as a function of exposure times through a dynamic mechanical analyzer. In addition. a suitable testing method for determining the effect of environmental factors on mechanical properties is suggested by comparing the results from using two different types of strain measuring sensors. Finally, composite surfaces exposed to environmental factors were examined using a scanning electron microscope.

Aging Characteristics of Glass Fabric/Phenolic Composites for Tilting Train Using Accelerated Aging Tester (가속노화시험장치를 적용한 틸팅열차용 유리섬유직물/페놀릭 복합재의 노화특성 평가)

  • Yoon Sung-Ho;Nam Jung-Pyo;Hwang Young-Eun;Lee Sang-Jin;Shin Kwang-Bok
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.188-194
    • /
    • 2005
  • Aging characteristics of glass fabric/phenolic composites for tilting train subjected to combined environmental aging factors were investigated. A 2.5KW accelerated aging tester with a xenon-arc lamp was used to provide environmental aging factors such as temperature, moisture, and ultraviolet. A series of aging tests were conducted up to 3000 hours and several types of specimens were prepared along the warp direction and the fill direction. Mechanical degradations for tensile, flexural, and shear properties were evaluated as a function of exposure times through a material testing system. Thermal analysis properties such as storage shear modulus, loss shear modulus, and tan 3 were measured through a dynamic mechanical analyzer. Finally exposed surfaces of the composites were examined using a scanning electron microscope. According to the experimental results, mechanical properties and thermal analysis properties of glass fabric/phenolic composites were found to be slightly degraded as a function of exposure times due to combined environmental effects.

Robotic Guidance of Distal Screwing for Intramedullary Nailing Using Optical Tracking System (광학식측정장치를 이용한 금속정 내고정 수술의 원위부 나사체결을 위한 로보틱 유도 시스템)

  • An, Liming;Kim, Woo Young;Ko, Seong Young
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.4
    • /
    • pp.411-418
    • /
    • 2017
  • During the intramedullary nailing procedure, surgeons feel difficulty in manipulation of the X-ray device to align it to axes of nailing holes and suffer from the large radiation exposure from the X-ray device. These problems are caused by the fact the surgeon cannot see the hole's location directly and should use the X-ray device to find the hole's location and direction. In this paper, we proposed the robotic guidance of the distal screwing using an optical tracking system. To track the location of the hole for the distal screwing, the reference marker is attached to the proximal end of an intramedullary nail. To guide the drill's direction robustly, the 6-degree-of-freedom robotic arm is used. The robotic arm is controlled so as to align the drill guiding tool attached the robotic arm with the obtained the hole's location. For the safety, the robot's linear and angular velocities are restricted to the predefined values. The experimental results using the artificial bones showed that the position error and the orientation error were 0.91 mm and $1.64^{\circ}$, respectively. The proposed method is simple and easy to implement, thus it is expected to be adopted easily while reducing the radiation exposure significantly.

An Experimental Study on Performance and Flow Characteristics of Automotive Sirocco Fan (자동차용 시로코팬의 성능 및 유동특성에 관한 실험적 연구)

  • 유성연;이대웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.954-963
    • /
    • 2002
  • For the optimal design of an automotive blower system, effects of the scroll cut-off starting angle, the clearance between blade tip and bellmouth, and the scroll expansion angle on the performance of sirocco fan are investigated experimentally. Best performance is achieved at fan exposure ratio $\Deltae/r_c$,/TEX> =1.0, and clearance ratio $\DeltaeC/C=0.62. Flow characteristics inside sirocco fan are also studied by using LDV. Flow patterns in the inside of fan can be classified into three regions. Velocity vector has the same direction as rotational direction of fan at 0~$120^{\circ}$, toward the fan blades at 150~$180^{\circ}$, and opposite direction at 210~$330^{\circ}$. Turbulent intensity is relatively high near the cut-off edge in the scroll housing.

Distribution and Management of Spatial Dose Rate in Neuro Angio Room (두개부 혈관조영실에서 공간산란선량의 분포와 관리)

  • Lee, Mi-Hwa;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Kim, Ki-Jeong;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • This study is performed in the intervention unit, during interventional procedures and in accordance with the direction and distance during the exposure indoor space is to measure the dose. I was classified at an angle of $45^{\circ}$ counterclockwise from the phantom. Seven(A, B, C, D, E, F, G) were classified as direction. Length was measured from the center of the phantom. Each direction 50cm, 100cm, 150cm, 200cm were classified. I was analyzed by measuring of frontal, lateral, Bi-plan fluoroscopic Spatial dose rate in all 28 points. Measured dose was the highest at 50cm and over 200cm, dose was rapidly decreasing as increased distance. Dose was different more than nine times depending on the distance and direction, Installation of shielding wall can reduce exposure about 84.52% to 93.54%.

Evaluation of Ride Vibrations of Agricultural Tractors (농업용 트랙터의 승차 진동 수준 평가)

  • Kim, H.J.;Kim, K.U.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.151-156
    • /
    • 2008
  • This study was conducted to evaluate ride vibrations experienced by tractor operators during plowing, rotovating, and transporting operations in Korea. Field data of ride vibrations were taken at the operator-seat interface from 49 tractors and analyzed on the basis of ISO 2631-1 and EU Directive 2002/44. Of the measured ride vibrations 15.4% in the plowing and 12.5% in farm road transport exceeded the 8-hour fatigue decreased proficiency boundary in the fore and aft directions at frequencies from 1 to 5 Hz. 93.9% exceeded the 8-hour potential health risk of ISO 2631-1. The ride vibrations exceeding the 8-hour exposure limit were 38.5% in plowing, 31.6% in rotovating, 100% in farm road transport and 88.9% in concrete road transport. Although most tractor operators were not exposed to ride vibrations greater than the 8-hour exposure limit value (ELV) of EU Directive 2002/44, 7.7% of the operators in the plowing experienced greater vibrations than the ELV in the fore-aft direction. Farm road transport produced greater vibrations than any other operations. Concrete road transport, plowing and rotovating operations followed next. Limit criteria for ride vibration exposure differ depending upon the guidelines. Exposure limit of the health guidance caution zone of ISO 2631-1 is lowest among its kinds.

Influence of Exposure Environmental Conditions on the Crack Healing Performance of Self-healing Repair Mortar Specimens (노출환경 조건이 자기치유형 보수 모르타르 시험체의 균열 치유성능에 미치는 영향)

  • Lee, Woong-Jong;Lee, Hyun-Ho;Ahn, Sang-Wook;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.283-288
    • /
    • 2018
  • Since the crack self-healing materials are activated according to the exposure environmental conditions from the time of crack occurrence, it is very important to clarify the relationship between the healing performance and the exposure environmental conditions of the crack surface. In this paper, the influence of the exposure environmental conditions on the crack healing performance of self-healing repair mortar was investigated through the water permeability test. The influence of temperature and humidity on the crack width of cracked specimens was evaluated. As a result of measuring the change of the crack width, the effect of curing temperature was negligible but it was confirmed that crack-closing occurred due to the change of dry-wet condition. The healing materials produced on the crack surface of the specimens was identified as calcite minerals. Since the minerals with high density are precipitated under the influence of gravity, the healing performance is somewhat different according to the direction of the crack surface, and the healing performance was significantly improved in the wet exposure condition than the air exposure condition.