• Title/Summary/Keyword: Exposure condition

Search Result 1,073, Processing Time 0.028 seconds

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions (심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가)

  • Seong-Bhin Koh;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

Science Festival and Science Communication: A Case Study for the April 1997's Science Month in Korea (과학축전과 과학커뮤니케이션 : 1997년 4월‘과학의 달’행사를 중심으로)

  • 김학수
    • Journal of Technology Innovation
    • /
    • v.6 no.1
    • /
    • pp.99-127
    • /
    • 1998
  • The purposes of this study are first, to plan communication strategies for promoting the 1st National Science Festival and other events of the April 1997's Science Month in Koreas; second, to monitor communication activities done for those events; third, to evaluate effects of communication activities. Both the Ministry of Science and Technology and the Korea Science Foundation were arranged to execute our planned communication strategies. Basically we utilized the three sequences of human behavioral condition : Exposure, attention, and cognition. For planning, we suggested concrete communication strategies for each sequence, for example, first, those for bringing exposure to every event, second, those for bringing attention to the event, and third, those for bringing cognition of the event. Those communication strategies were suggested to use specifics of newspapers, television programs, radio programs, commercial and corporate magazines, electric visual sign advertisements on the street, and computer communication. For monitoring and evaluation, we used the same three sequences as the criteria. For example, we monitored and evaluated how much exposure, attention or cognition an event got or which specific medium contributed to exposure to, cognition of an event. For monitoring, graduate students were dispatched to examine each event through watching and interviewing. For evaluation, about 950 of event participants and non-participants were surveyed by means of face-to-face interview. Overall, we found that newspaper articles and television programs contributed a lot to people's exposure to events of the April 1997's Science Month. Especially, newspaper played a major role of heightening exposure. However, most events and/or their science and technology content failed to get salient attention and its following active cognition. The 1st National Science Festival attracted much exposure, but had some problems of disorder and commercialism. This sharp increase of exposure and some attention were believed to have reinforced people's, especially event participants' positive opinion of science and technology which is part of scientific culture.

  • PDF

Attention Degradation of Occupant Driving Vehicle on Cross-country Test Road According to Vibration Exposure Time (야지 시험로 주행 진동 노출 시간에 따른 탑승자의 주의력 저하에 관한 연구)

  • Park, Dong-Jun;Choi, Moon-Gee;Song, Jong-Tak;Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.155-161
    • /
    • 2017
  • When a military vehicle is driven on a cross-country road, the occupants are exposed to vibration at a body resonance. In case that the exposure continues for too long period, the attention ability of the occupant could be affected by the vibration exposure. In the study, it was experimentally tried to find if there is a correlation between degradation of attention and vibration exposure. Two kinds of test among various psychological attention tests were employed, which were selected with considering a situation of carrying out military mission on vehicle. At the result, the searching test for controlled attention showed significant degradation in the accuracy and performance time in case of exposure at the vibration. And the attention degradation appeared to be greater when the vibration exposure increases. The dual task test for divided attention showed the difference between vibration and non-vibration condition, but showed it is insignificant for the attention to degrade by increasing exposure time.

A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level (진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구)

  • Park, Hye-Min;Yoon, Yong-Su;Kim, Eun-Hye;Jeong, Hoi-Woun;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

Monitoring of Corrosion Rates of Carbon Steel in Mortar under a Wet-Dry Cyclic Condition

  • Kim, Je-Kyoung;Kang, Tae-Young;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • The corrosion behavior of metal covered with mortar under a wet-dry cyclic condition were investigated to apply for the measurement of corrosion rates of reinforcing steel in concrete structure. The carbon steel in mortar having t=3 mm cover thickness was exposed to the alternate condition of 6 h immersion in chloride containing solution and 18 h drying at $25^{\circ}C$ and 50%RH. The electrochemical phenomena of a carbon steel and mortar interface was explained by an equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE(Constant Phase Element). The corrosion rates were monitored continuously during exposure using an AC impedance technique. Simultaneously, the current distribution over the working electrode during impedance measurement was analyzed from the phase shift, $\theta$, in an intermediate frequency. The result showed that corrosion rate monitoring using an AC impedance method is suitable under the given exposure conditions even during the drying period when the metal is covered with the wetted mortar.

Influence of Light Intensities on Clothing Behavior and Melatonin Secretion (조도의 차이가 의복착의행동 및 멜라토닌 분비에 미치는 영향)

  • Kim, Hee-Eun;Tokura, Hiromi
    • Fashion & Textile Research Journal
    • /
    • v.6 no.5
    • /
    • pp.613-617
    • /
    • 2004
  • The intent of this study was to determine whether different light exposure could modify the clothing behavior in the evening cold environment or not. Nine female subjects volunteered to this study. In a bright light or a dim light condition, light intensity was controlled 3000 lx or 10 lx respectively. Subjects were introduced to wear various kinds of garments whenever they need to feel comfortable as the room temperature began to decrease. The room temperature was lowered from $30^{\circ}C$ to $15^{\circ}C$ for one hour (21:00 h~22:00 h) and maintained at $15^{\circ}C$ for additional one hour (22:00 h~23:00 h). Subjects stayed in chamber from 08:00 to the next day 07:00. Clothing behavior, core temperature, subjective temperature sensation and melatonin secretion were measured. Most subjects put on the clothing more quickly and more thickerly in the bright light rather than in the dim light condition. The fall of core temperature during night was significantly less under the bright light in the late afternoon, suggesting that the set-point of core temperature has been set at a higher level during the evening and the night, being supported by the less amount of melatonin secretion. Thus, it is concluded that the quicker dressing behavior with thicker clothing in the "Bright" condition is advantageous in evening cold exposure, since it enables the core temperature to reach its set-point value more easily.

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

The Study of Exposure and Concealment in Fashion - Focusing on the Freud's Psychoanalysis - (패션의 노출과 은폐에 관한 고찰 - Freud의 정신분석학을 중심으로 -)

  • 임성민;박민여
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.11
    • /
    • pp.1395-1403
    • /
    • 2004
  • Exposure and Concealment have been continued as important way to express fashion and theme as well, especially in women fashion. Exposure can make themselves attractive, and concealment emphasizes this way of being attractive by exposure. Besides the temptable effect of exposure, the ideology which put women next men in society has made a prominence on the fact exposure is significant theme in women fashion. It means that women's image of 'Being seen as Object' (this can be explained by relation passive between active) in society has driven female emphasize in using and focusing on exposure to be attractive. Also the other important thing in women fashion has been considered is concealment. The fact that society has demand women more chaste duty in detail may have meaningful thing in the condition that instigates women take off being attractive to the subject, considering ideology, men. Therefore attractive femininity has to be suggested by virtue and temptation, it is common sense that looking just shallow or too strict are far from criteria of ideal beauty. Namely, the concept for exposure coexists with concealment not only constructively but also naturally in fashion. Technique that can be accentuate for effective exposure differently from method to show unilaterally is needed, and this technique can promote new fashion. And according to the theory of Freud, women means' Absence (lacking penis)', this female's Lack Image induces male castration complex therefore 'Fetishistic Look' which transfers something phallic into specific things or parts of body is adopted, sort of object cathexis. This is revealed as some parts of women body are diverted into object for sexual love, symbolic equivalent. For example, women's parts like legs or breast are remarked as erotogenic zone and as time goes, when no more the zone are felt sexual by exposure, other somewhere felt mysterious (felt something sexual) used to be stressed by exposing. As it were, it can be possible that exposing part on women body (sexual part) moved as time passed because of what previously stated. Especially, the concept of exposure and concealment in women fashion should explain not only from a point of view of style for the beautifulness but also from wearer's immanent intention, further more relationship with ideology. About the present situation becoming bolder in women fashion, it is said that women express confidence as the position of women is elevated higher socially, the more women get freedom. But if we consider this psychoanalysis opinion mentioned ahead, the possibility can not be excluded that the exposure can get emphasizing according as the need of feminine modesty gets decreasing from ideal femininity society, men want. This study about exposure and concealment was made progressed through the theory of Freud who originated psychoanalysis, presented many theories. But nowadays contradictions are being brought up against Freud's theory including conventional philosophy like male chauvinism and adjust studies get suggested. Hereupon, there may be limitation in making no allowance of contradiction and following his theory.