• 제목/요약/키워드: Exposure Time

검색결과 3,561건 처리시간 0.033초

사회·인구학적 요인과 시간활동양상에 따른 톨루엔 개인노출의 영향요인 분석 (Affecting Factors of Personal Exposure to Toluene according to Sociodemographic Characterization and Time-activity Pattern)

  • 정순원;이석용;김현정;최욱희;김수진;유승도;양원호
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.157-166
    • /
    • 2017
  • Objectives: Exposure to hazardous air pollutants could be affected by sociodemographic factors such as age, gender and more. Information on time spent in microenvironments has a critical role in exposure assessment. The purpose of this study was to analyze the exposure pathways which influence personal exposure through time-activity patterns and sociodemographic factors. Methods: A total of 379 subjects were collected from the second term of the Korean National Environmental Health Survey. A questionnaire survey in relation to sociodemographic factors and a time-activity diary were carried out for personal exposure to toluene. Focusing on personal exposure to toluene, factors affecting personal exposure were analyzed using multiple regression analysis. Results: Participants spent their time in an indoor house for $16.8{\pm}4.0hr$, workplace or school $2.3{\pm}3.5hr$, and other indoor $2.1{\pm}2.2hr$. Sociodemographic factors were significantly different among each personal exposure and microenvironment. Time of staying at an office turned out to be a main factor from point of exposure in exposure pathway using multiple regression analysis. As a result, this means that exposure may be different according to the time of staying in each microenvironment. Conclusions: Personal exposure to air pollutants might be decided by time-activity pattern indicating when, where, and which activities people pursue, as well as individual sociodemographic factors.

실시간성과 강건성을 갖는 CMOS 자동노출 시스템 (CMOS Image Automatic Exposure System With Real-time and Robustness Style for the Journal of Korean Contents)

  • 최원석;김희수;김재현;조영기;최성호;이용선
    • 한국콘텐츠학회논문지
    • /
    • 제20권10호
    • /
    • pp.1-13
    • /
    • 2020
  • CMOS 카메라 영상의 화질을 좌우하는 것은 여러 가지가 있는데 그 중에서 영상 노출시간은 중요한 요소이다. 영상 노출시간이 길게 되면 화면 전체 영상이 밝아지게 되고 노출시간이 짧아지면 전체 영상이 어두워지게 된다. 정지 피사체를 사진 촬영할 경우 자동노출 시스템이 적절한 노출시간을 얻는데 충분한 시간이 주어지기 때문에 실시간성이 요구되지 않는다. 하지만 주행 중인 자동차의 블랙박스 같이 주변 빛 환경이 빠르게 변하게 되면 이에 맞추어서 노출시간도 실시간으로 반응하여 적용되어야 한다. 이를 위해서는 실시간성과 주변 빛 환경에 대하여 강건한 자동노출 시스템이 요구된다. 본 논문에서는 ZYNQ의 로직과 ARM코어를 적용한 임베디드 시스템 설계로 병렬 연산처리 가능한 실시간 제어 시스템을 설계하였고 이를 바탕으로 PID 제어를 통해서 66ms 이내에 원하는 목표 값으로 수렴하고 노이즈에 강건한 실시간 CMOS 자동 노출 시스템을 개발하였다.

제철소 근로자의 벤젠/톨루엔/크실렌 국소환경 측정을 이용한 총 노출 예측 (Estimation of Total Exposure to Benzene, Toluene and Xylene by Microenvironmental Measurements for Iron Mill Workers)

  • 김영희;양원호;손부순
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.359-364
    • /
    • 2007
  • The aim of this study were to assess the personal exposure to volatile organic compounds (VOCs) and to estimate the personal exposure using time-weighted average model. Three target VOCs (benzene, toluene, xylene) were analyzed in personal exposure samples and residential indoor, residential outdoor and workplace indoor microenvironments samples in the iron mill 30 workers during working 5 days. Personal exposure to VOCs significantly correlated with workplace concentration p<0.05), suggesting workplace had strong source and major contribution to personal exposure. Personal exposure could be estimated with time activity pattern and time weighted average (TWA) model of residential indoor and workplace concentrations measured. Time weighted mean microenvironments concentrations were close approximately of personal exposure concentrations. Total exposure for participants can be estimated by TWA with microenvironments measurements and time activity pattern.

세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례 (TCE Exposure Assessment of Cleaning Workers)

  • 김현수
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

노출평가 방법론에 대한 과거와 현재, 그리고 미래 (Review of Exposure Assessment Methodology for Future Directions)

  • 곽수영;이기영
    • 한국환경보건학회지
    • /
    • 제48권3호
    • /
    • pp.131-137
    • /
    • 2022
  • Public interest has been increasing the focus on the management of exposure to pollutants and the related health effects. This study reviewed exposure assessment methodologies and addressed future directions. Exposure can be assessed by direct (exposure monitoring) or indirect approaches (exposure modelling). Exposure modelling is a cost-effective tool to assess exposure among individuals, but direct personal monitoring provides more accurate exposure data. There are several population exposure models: stochastic human exposure and dose simulation (SHEDS), air pollutants exposure (APEX), and air pollution exposure distributions within adult urban population in Europe (EXPOLIS). A South Korean population exposure model is needed since the resolution of ambient concentrations and time-activity patterns are country specific. Population exposure models could be useful to find the association between exposure to pollutants and adverse health effects in epidemiologic studies. With the advancement of sensor technology and the internet of things (IoT), exposure assessment could be applied in a real-time surveillance system. In the future, environmental health services will be useful to protect and promote human health from exposure to pollutants.

정자의 전처리시간, 농도 및 공동배양시간이 돼지난포란의 체외수정에 미치는 영향 (Effect of Preincubation Time, Concentration and Exposure Time of Sperm on In Vitro Fertilization of Porcine Follicular Oocytes Matured in In Vitro)

  • 박병권;임정훈;방남수;이규승
    • 한국수정란이식학회지
    • /
    • 제11권3호
    • /
    • pp.225-231
    • /
    • 1996
  • This study was conducted to investigate the effects of preincubation time, concentration and exposure time of sperm on in vitro fertilization of porcine follicular oocytes rnatured in in vitro. The results obtained are as follows ; 1. Effect of preincuhation time for porcine sperm capacitation on in vitro fertilization in medium with heparin was investigated. Normal fertilization rate was highest in 15 min(26.4%). However, there were no significant differences among preincuhation times of 5~90 min, 2. Normal fertilization rates of sperm concentrations were 17.0~26.5%, and normal fertilization rate from l$\times$ l05cell /ml concentration was also higher than those of other sperm concentration. 3. Normal fertilization rates of sperm exposure time of 4, 8, 12, 16 and 20 hours were 6.1, 20.8, 27.8, 25.0 and 26.7%, respectively. Normal fertilization rate from sperm exposure time of 12 hours was also higher than that of other sperm exposure times.

  • PDF

Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구 (THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST)

  • 유영선;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

어린이용품 함유 유해인자의 위해성평가를 위한 노출계수 조사 (Survey of Exposure Factors for Risk Assessment of Hazardous Materials in Child-Specific Products)

  • 김정곤;서정관;김탁수;박건호
    • 한국환경보건학회지
    • /
    • 제40권1호
    • /
    • pp.17-26
    • /
    • 2014
  • Background: Despite children's unique characteristics that distinguish them from adults, relatively few attempts have been made to measure exposure factors for characterization of children's exposure to hazardous chemicals in child-specific products (CSP). This study was conducted to establish the child-specific exposure factors for exposure and risk assessment of hazardous substances in CSP. Methods: We investigated the exposure factors (e.g., time use of child-products, time and frequency of object-to-body contact, time and frequency of object-to-mouth contact) influencing children's exposure to CSP (e.g., toys, playmats, oil pastels, etc.) in 650 children through a parent-completed questionnaire using a web-based survey. Participants were recruited in five age groups, <1, 1-2, 2-3, 3-6, and 6-12 years of age. Results: The child-specific exposure factors were presented as the mean, median, $95^{th}$ percentile, minimum, and maximum values. Time activity for play mats was the longest among CSP and infants spent more time on them than did elder age groups (189.3-224.7 min/day for <1-2 years vs. 91.2 min/day for 6-12 years). It is apparent that time and frequency of toy block- and plastic toy-to-mouth contact significantly decreased as a function of age. When the variation of CSP use patterns was compared by gender, the only variable that was statistically different between genders was time activity in child-products exposure space. Conclusion: We believe the five child-specific exposure factors suggested in the present study will be valuable for reducing uncertainty in the estimation of chemical exposure during risk assessment of CSP and furthermore, in the appropriate regulations to protect children's health.

Buckling capacity of uniformly corroded steel members in terms of exposure time

  • Rahgozar, Reza;Sharifi, Yasser;Malekinejad, Mohsen
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.475-487
    • /
    • 2010
  • Most of steel structures in various industries are subjected to corrosion due to environmental exposure. Corrosion damage is a serious problem for these structures which may reduce their carrying capacity. These aging structures require maintenance and in many cases, replacement. The goal of this research is to consider the effects of corrosion by developing a model that estimates corrosion loss as a function of exposure time. The model is formulated based on average measured thickness data collected from three severely corroded I-beams (nearly 30 years old). Since corrosion is a time-dependent parameter. Analyses were performed to calculate the lateral buckling capacity of steel beam in terms of exposure time. Minimum curves have been developed for assessment of the remaining lateral buckling capacity of ordinary I-beams based on the loss of thicknesses in terms of exposure time. These minimum curves can be used by practicing engineers for better estimates on the service life of corrosion damaged steel beams.

Fracture toughness of high performance concrete subjected to elevated temperatures Part 2 The effects of heating rate, exposure time and cooling rate

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • 제5권5호
    • /
    • pp.513-537
    • /
    • 2017
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was investigated by conducting three-point bending tests on a total of 240 notched beams of $500mm{\times}100mm{\times}100mm$ subjected to heating temperatures up to $450^{\circ}C$ with exposure times up to 16 hours and various heating and cooling rates. For a heating rate of $3^{\circ}C/min$, $K_{IC}$ for the hot concrete sustained a monotonic decrease trend with the increasing heating temperature and exposure time, from $1.389MN/m^{1.5}$ at room temperature to $0.942MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.906MN/m^{1.5}$ for 8-hour exposure time and $0.866MN/m^{1.5}$ for 16-hour exposure time. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and then rapidly down to $0.869MN/m^{1.5}$ at $450^{\circ}C$ for 4-hour exposure time, $0.812MN/m^{1.5}$ for 8-hour exposure time and $0.771MN/m^{1.5}$ for 16-hour exposure time. In general, the $K_{IC}$ values for the hot concrete up to $200^{\circ}C$ were larger than those for the cold concrete, and an inverse trend was observed thereafter. The increase in heating rate slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.893MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.839MN/m^{1.5}$ for $10^{\circ}C/min$ for the hot concrete and from $0.792MN/m^{1.5}$ for $1^{\circ}C/min$ to $0.743MN/m^{1.5}$ for $10^{\circ}C/min$ for the cold concrete after an exposure time of 16 hours. The increase in cooling rate also slightly decreased $K_{IC}$, and at $450^{\circ}C$ $K_{IC}$ decreased from $0.771MN/m^{1.5}$ for slow cooling to $0.739MN/m^{1.5}$ for fast cooling after an exposure time of 16 hours. The fracture energy-based fracture toughness $K_{IC}$' was also assessed, and similar decrease trends with the heating temperature and exposure time existed for both hot and cold concretes. The relationships of two fracture toughness parameters with the weight loss and the modulus of rapture were also evaluated.