• Title/Summary/Keyword: Exposure Apparatus

Search Result 64, Processing Time 0.026 seconds

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure (휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출)

  • Youn Ji-Hun;Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.810-814
    • /
    • 2005
  • Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.

The relationship between the utilization of health center and exposed amount to solvent by using cumulative exposure index (누적 폭로지수를 이용한 유기용제 폭로량과 의무실 이용간의 관계)

  • Park, Ju-Won;Lee, Soon-Young;Jang, Jae-Yeon;Lee, Kyung-Jong;Jeong, Ho-Gun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.404-413
    • /
    • 1998
  • This study was conducted in order to clarify the factors affecting the number of utilization to health center for the shipyard workers who have been work in exposed environment to solvent. At first the tendencies of the number of utilization to health conte. in accordance with cumulative exposure(CE), lifetime weighted average exposure(LWAE), one's place of duty, work contents, states of using safety apparatus, the degree of the knowledge on handling solvents, exposure year. 1). The increase in the cumulative exposure(CE) war significantly higher in the number of utilization to health center. The group with longer exposure year showed significantly higher number of utilization to health center(p<0.01). Considering the work contents such as power blasting, spray, mixing and touch-up, the group of touch-up showed higher number of utilization to health center and this difference was statistically significant(p<0.001). Those who were not using the safety apparatus, showed higher number of utilization to health center, which was statistically significant(p<0.05). The degree of the knowledge on handling the solvent had no relation with using health center. 2) The results conducted from this study by multiple regression analysis in clarifying the factors affecting the number of utilization to health center, CE, exposure year and using safety apparatus was significant factor in utilization of health center.

  • PDF

Effects of Human Activity Patterns on Personal Exposure Levels of Nitrogen Dioxide in A-San Area (아산지역에 있어서의 $NO_{2}$ 개인 피폭량에 미치는 각종 생활행동 패턴의 영향)

  • 손부순;김대선;정문식
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.47-52
    • /
    • 1996
  • Personal exposure levels of $NO_{2}$ for office workers and housewives Living in A-San and neighboring prefectures were measured in two seasons with $NO_{2}$ filter badge. $NO_{2}$ concentrations in indoor and outdoor air in their offices and houses were also measured in the same periods. Personal exposure levels in winter ranged from 13 to 132 ppb and its distribution pattern was remarkably different from the other seasons (15.2-17.9 ppb). This fact suggests that use of heating apparatus affects largely $NO_{2}$ indoor air pollution in winter seasons. Actually, $NO_{2}$ exposure levels of subjects used Kerosene heater (43.6ppb) and gas heater (33.4ppb) were higher than those of subjects unused heating apparatus (18.0ppb). Personal exposure levels of $NO_{2}$ for man and woman Living in the same houses were correlated well each other. The time spent indoors for office workers and housewives were both longer than 22 hour a day. Home staying time was about 60% of total indoor staying time for office workers and 90% or more for housewives. Personal exposure levels were significantly related to indoor exposure levels at home all seasons. Furthermore, personal exposure levels could be estimated from $NO_{2}$ concentrations and staying times in various Living environment.

  • PDF

Retinoic Acid-Induced Golgi Apparatus Disruption in F2000 Fibroblasts: A Model for Enhanced Intracellular Retrograde Transport

  • Tzankov, Alexandar
    • BMB Reports
    • /
    • v.36 no.3
    • /
    • pp.265-268
    • /
    • 2003
  • Retinoic acid (RA) can transform the Golgi apparatus (GA) into a diffuse vacuolar aggregate and increase the toxicity of some immunotoxins that enter into cells by receptor-mediated endocytosis. An ultramorphological study of the RA-induced GA disruption was performed on F2000 fibroblasts. Cultures were treated with 0.11 to $30\;{\mu}M$ RA for 7 - 180 min. The endocytosis of Limax flavus agglutinin-peroxidase conjugate (LFA), and the interactions between a phorbol ester (PMA) and RA concerning GA disruption, were examined. Exposure to $0.33\;{\mu}M$ RA for 20 min transformed the GA into vacuolar aggregate. These vacuoles were not involved in endocytosis since they remained unstained after endocytosis of LFA. However, the lysosomes were involved in endocytosis, as they were strongly stained. Therefore, a RA-induced shift towards lysosomal routing of the entered LFA was presumed. Exposure to PMA made cells resistant to the Golgi-disturbing effects of RA, indicating that protein kinase C plays an important role in this process.

Development of a tide-simulating apparatus for macroalgae

  • Kim, Jang-K.;Yarish, Charles
    • ALGAE
    • /
    • v.25 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • A tide-simulating apparatus was developed for culturing marine macroalgae. The objective of this study was to introduce a novel tide-simulating apparatus that can simulate a diurnal or semi-diurnal tidal cycle in the laboratory. In this apparatus, the seaweeds are move up and down and the water level remains the same during the simulated tidal cycle. The apparatus consists of 18 cylindrical culture tanks (3 blocks $\times$ 6 culture tanks) with 12 cm diameter and 24.5 cm long containing up to 2.5 L of seawater. There is a horizontal plate which covered all 18 culture tanks, and it is raised and lowered by a programmable motor that can regulate exposure time. In one application, seaweeds are attached to braided twine hung on Plexiglas air-tubing. The air-tubing is attached to a lid that is set on a horizontal plate. This apparatus is made of colorless Plexiglas to maximize light transmittance. This apparatus is easily disassembled and transportable to any indoor laboratory, wet laboratory, greenhouse, etc. This apparatus also offers considerable flexibility in terms of design. The size of culture tank can be redesigned by either increasing the height of cylinder or/and using a different diameter of cylindrical Plexiglas, therefore, larger/taller thalli can be cultivated. Growth rates of three eulittoral Porphyra species from different tidal elevations have been compared using this device.

Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography (콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가)

  • Han, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.353-360
    • /
    • 2020
  • This research aims at suggesting exposure condition that shows maintaining the value of the physical image quality factor by decreasing tube voltage and tube current from the standard exposure condition(80 kV, 7 mA) of a CBCT apparatus. To measure the value of the physical image quality factor, modular transfer function(MTF) was analyzed and dose-area product(DAP) was used for the measurement of exposure dose. CBCT images of a Sedentex IQ phantom were obtained under 15 exposure conditions of different combination of tube voltage(80, 78, 76 kV) and tube current(7, 6, 5, 4, 3 mA) and MTF 10 was calculated under each exposure conditions. There were no significant differences in MTF 10 under 80 kV-6 mA, 80 kV-5 mA exposure conditions in comparison with standard exposure condition. Based on the results of this research, 80 kV-5 mA condition are expected to be able to reduce exposure dose with maintaining the value of the physical image quality factor of the standard exposure condition.

Work Conditions and Practices in Norwegian Fire Departments From 1950 Until Today: A Survey on Factors Potentially Influencing Carcinogen Exposure

  • Jakobsen, Jarle;Babigumira, Ronnie;Danielsen, Marie;Grimsrud, Tom K.;Olsen, Raymond;Rosting, Cecilie;Veierod, Marit B.;Kjaerheim, Kristina
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.509-516
    • /
    • 2020
  • Background: Meta-analyses have shown firefighters to be at an increased risk of several cancer types. Occupational carcinogen exposure may explain these increased risks. This study aims to describe Norwegian fire departments' work conditions from 1950 until today, focusing on factors relevant for potential occupational carcinogen exposure. Methods: With the help of a reference group, we developed a questionnaire on topics related to occupational exposure to carcinogens for the period 1950-2018. Selected Norwegian fire departments provided department-specific responses. Results: Sixteen departments, providing fire services for 48% of the Norwegian population as of 2019 and mainly consisting of professional firefighters, responded to our questionnaire. The introduction of synthetic firefighting foams, more regular live fire training, the introduction of chemical diving, and a higher number of diesel-driven fire service vehicles were identified as changes thought to increase exposure to occupational carcinogens. Changes thought to decrease exposure included the switch from negative to positive pressure self-contained breathing apparatuses, the use of self-contained breathing apparatuses during all phases of firefighting, the use of ventilating fans during firefighting, increased attention to flammable materials used during live fire training, increased attention to handling and cleaning of turnout gear and other equipment, and installment of exhaust removal systems in apparatus bays. Conclusion: Norwegian fire departments' work conditions have seen several changes since 1950, and this could influence firefighters' occupational carcinogen exposure. A peak of carcinogen exposure may have occurred in the 1970s and 1980s before recent changes have reduced exposure.

Development of an Apparatus for the Determination of In Vitro Metabolic Rate Constants of Volatile Organic Chemicals (휘발성 유기용매의 In vitro 대사속도 측정 장치의 개발)

  • Hwang, In-Young;Lee, Yoon
    • Environmental Analysis Health and Toxicology
    • /
    • v.12 no.3_4
    • /
    • pp.43-54
    • /
    • 1997
  • Species, doses and routes extrapolation can be sucessfully carried out by using a physiologically-based pharmacokinetic (PBPK) approach. And PBPK approach to assess risk of hazardous chemicals is reasonable whatever the exposure scenarios are happened. Both partitioning coefficients of chemical between tissue and blood and enzymatic metabolic rate constants are key parameters to build up the PBPK model. In this study, we tried to estimate in vitro metabolic rate constants using a special apparatus instead to measure the in vivo constants which are used to PBPK simulation since the in vitro tests are less expensive and more convenient than in vivo tests. For the purpose, we designed and tested the new system to measure continuously the headspace concentration of VOC. The newly designed system is composed with a diffusion chamber which generates gaseous substrate, a reaction vessel with a recirculating pump to establish a closed system, an autbmatic sampler from a gas phase, a gas chromatography to analyze the headspace. In addition, a cold water condenser is attached between the reaction vessel and pump to reduce the content of gaseous moisture which interferes with chemical analysis. To validate the newly developed methodology, in vitro metabolic rate constants of trichloroethylene (TCE) as a prototype VOC were estimated by simulating observed results with an ACSL program. The simulated results are consistent to those estimated by the other research groups. This finding suggests that our newly designed closed system may be a useful apparatus to estimate in vitro metabolic rate constants for VOC.

  • PDF

Management Strategies for Electromagnetic Fields in Electric Power Lines (고압선로에서 발생하는 전자기장의 위해성 관리 방안)

  • 전인수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1017-1023
    • /
    • 2003
  • Recently, the use an electric apparatus has brought into concerns about health risks from exposure to electromagnetic fields. During the last 2 decades, a number of epidemiological studies have explored the association between childhood leukaemia and residential exposure to power-frequency electromagnetic fields. Several studies have suggested that there is a small excess leukaemia risk with magnetic field exposure above 2 mG. A number of governmental and international organizations have developed exposure gudelines. The most rigid regulation with exposure levels for the elementary school and hospital has been enacted by Switzerland. Although there is no convincing supportive laboratory evidence, and the absence of a plausible biological mechanism of disease causation limits, governments are increasingly called on to adopt precautionary approaches to regulating electromagnetic field exposures. The government would need to establish the policy for electromagnetic fields and continually to be concerned about possible health risks from exposure to electromagnetic fields.