• Title/Summary/Keyword: Exposed dose

Search Result 1,111, Processing Time 0.031 seconds

ESTIMATION OF ABSORBED DOSE IN OCCLUSAL RADIOGRAPHY (교합방사선사진 촬영시의 흡수선량 계측)

  • Yoo Young Ah;Choi Karp Shik;Lee Sang Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.103-112
    • /
    • 1990
  • The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-2l0 Head & Neck Section/sup R/, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70Kvp and 15mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  • PDF

Studies on Digitalis Receptor Desensitization in Rat Ventricle

  • Lee, Shin-Woong-;Jang, Tae-Soo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.301-301
    • /
    • 1994
  • $^3$H〕Ouabain binding parameters(K$\_$D/ and B$\_$max/,) in homogenates prepared fpom control rat ventricular strip and Langendorff preparations which were not previously exposed to ouabain were compared to those in homogenates from ventricular strip and Langendorff preparations that had been first exposed to a complete ouabain dose-response curve(10$\^$-7/M to 10$\^$-4/ M). In rat ventricular strips and Langendorff perfused rat heart preparations, cumulative dose-response cruves of ouabain revealed biphasic positive inotropic effects, a "low-dose" and a "high-dose" effect with ED$\_$50/ values of 0.5${\mu}$M and 35${\mu}$M ouabain, respectively- The "low-dose" effect in rat ventricular strips disappeared or was diminished significantly when the ouabain dose-response curve wag repeated after the washout of the effects of the first curve, whereas the maximal "high-dose" effect was identical in both exposures to oubain. However, there was no change in the "low-dose" effects in both sets of the Langendorff perfused hearts. The contractile activity of the pre-exposed strips did not indicate the presence of residual ouabain since their basal contractile force was decreased 10% compared to initial control. 〔$^3$H〕Ouabain binding parameters, K$\_$D/ and B$\_$max/, were not changed comparing homogenate of control ventricular strips with that of strips pre-exposed to ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site(${\alpha}$$_2$ isoform).

  • PDF

Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System (유방영상시스템에서 수학적 모의피폭체를 이용한 선량평가)

  • Lee, Jinsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.155-161
    • /
    • 2014
  • Mammography is mostly performed by series projection on both breasts. While taking mammography, it is less than average glandular dose of 3 mGy which regulated. But mammography is exposed much more doses actually, due to additional or series projection. Also, it is difficult to recognize around organ dose except exposed breast. Using mathematical simulation of radiation exposure body in mammography, we studied around organ dose distribution by changing thickness(25, 30, $50{\mu}m$) of filter and relative absorption dose rate which set on basis of exposed breast. as a result, when setting of basis of exposed breast, dose of opposite breast is more affected approximately from 79.26 to 86.31%. when using $25{\mu}m$ of filter thickness than $30{\mu}m$, $50{\mu}m$ of filter thickness in Mo/Mo, W/Rh combination which used actually, absorbed dose rates for opposite breast and around organ were low.

Administrative dose control for occupationally-exposed workers in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Jung, Yoonhee;Kim, Jeong Mi;Cho, Moonhyung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.351-356
    • /
    • 2021
  • Korean nuclear power plants (NPPs) have various radiation protection programs to attain radiation exposure as low as reasonably achievable (ALARA). In terms of ALARA, this paper provides a comprehensive overview of administrative dose control for occupationally-exposed workers in Korean NPPs. In addition to dose limits, administrative dose constraints are implemented to resolve an inequity of radiation exposure in which some individuals in NPPs receive relatively higher doses than others. Occupational dose constraints in Korean NPPs are presented in this paper with the background of how those values were determined. For pressurized water reactors, 80% and 90% of the annual average limit for an effective dose, 20 mSv/y, are set as the primary and secondary dose constraints, respectively. Pressurized heavy water reactors (PHWRs) have also established the primary and secondary dose constraints corresponding to 70% and 80% of the effective dose limit, and additional constraints for tritium concentration are provided to control internal exposure in PHWRs. Follow-up measures for exceeding these administrative dose constraints are also introduced compared to exceeding the dose limits. Finally, analysis results of dose distributions show how the implementation of administrative dose constraints impacted the occupational dose distributions in Korean NPPs during the years 2009-2018.

Yookmijihwang-Tang on the Plasma Corticosterone level in Mice exposed to Heat, Cold and Immobilization Stress (한(寒), 열(熱), 구속(拘束) 스트레스에 대한 사군자탕(四君子湯), 사물탕(四物湯), 육미지황탕(六味地黃湯)의 효능(效能))

  • Kang Young-Gun;Lee Tae-Hee
    • Herbal Formula Science
    • /
    • v.10 no.2
    • /
    • pp.97-112
    • /
    • 2002
  • In order to investigate the effect of Sagoonja-Tang, Samool-Tang and Yookmijihwang-Tang against the cold, heat and immobilization stress, each formula was injected intragastically to mice exposed to forced cold water swimming($4^{\circ}C$), forced hot water swimming($42^{\circ}C$) and immobilization stress before measuring the change of plasma corticosterone level of mice. The results were as follows: 1. One hour after each Sagoonja-Tang, Samool-Tang, Yookmijihwang-Tang with the dose of 1g/kg, 3g/kg each were administered to mice, we put cold stress($4^{\circ}C$) on mice for 3min. Then those prescriptions didn't show any significant effect on plasma corticosterone level. however, Yookmijihwang-Tang(1g/kg) showed a significant increase(p〈0.05), and Samool-Tang(3g/kg) showed a small increase. 2. One hour after Samool-Tang, Sagoonja-Tang and Yookmijihwang-Tang with the dose of 1g/kg, 3g/kg each were administerd, mice exposed to heat stress($42^{\circ}C$) for 3 min. Samool-Tang(1g/kg) and Yookmijihwang-Tang(lg/kg) showed significant decrease of corticosterone level(p〈0.01, p〈0.05) but Sagoonja-Tang didn't change it. In the case of the dose of 3g/kg, only Samool-Tang decreased corticosterone level(P〈0.01), but Sagoonja-Tang, Yookmijihwang-Tang didn't make significant effect on plasma corticosterone level of the mice exposed to heat stress($42^{\circ}C$ ). 3. Those mice which exposed to immobilization stress one hour after Sagoonja-Tang, Samool-Tang, Yookmijihwang-Tang with the dose of 1g/kg and 3g/kg didn't show effective decrease of corticosterone level. However, Sagoonja-Tang(3g/kg), Samool-Tang(lg/kg, 3g/kg) showed the effect of mild increase of corticosterone level rather than decrease. These data revealed that the effect-variation of prescriptions depended on the kinds of stress and the dose of prescriptions had a different effect on therapy.

  • PDF

Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode (실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현)

  • 이운근;백광렬;권석근
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.4
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

CHANGES IN BODY AND ORGAN WEIGHTS, HEMATOLOGICAL PARAMETERS, AND FREQUENCY OF MICRONUCLEI IN THE PERIPHERAL BLOOD ERYTHROCYTES OF ICR MICE EXPOSED TO LOW-DOSE-RATE $\gamma$-RADIATION

  • Kang, Yu-Mi;Shin, Suk-Chul;Jin, Young-Woo;Kim, Hee-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.102-106
    • /
    • 2009
  • We exposed ICR mice to low-dose (0.2 Gy) and low-dose-rate (0.7 mGy/h) $\gamma$-radiation ($^{137}Cs$) in the Low-dose-rate Irradiation Facility at the Radiation Health Research Institute to evaluate systemic effects of low-dose radiation. We compared the body and organ weights, number of blood cells (white and red blood cells and platelets), levels of biochemical markers in serum, and frequency of micronuclei in polychromatic erythrocytes between low-dose irradiated and non-irradiated control mice. The ICR mice irradiated with total doses of 0.2 and 2 Gy showed no changes in body and organ weights, number of blood cells (white and red blood cells), or frequency of micronuclei in the polychromatic erythrocytes of peripheral blood. However, the number of platelets (P = 0.002) and the liver weight (P < 0.01) were significantly increased in mice exposed to 0.2 and 2 Gy, respectively. These results suggest that a low-dose-rate of 0.7 mGy/h does not induce systemic damage. This dose promotes hematopoiesis in the bone marrow microenvironment and the proliferation of liver cells. In the future, the molecular biological effects of lower doses and dose rates need to be evaluated.

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

Effects of Taste and Quality of Drugs on the Plasma Corticosterone Level in Mice exposed to Heat and Cold Stress (한약(韓藥)의 기미(氣味)가 한열자극(寒熱刺戟)을 받은 생쥐의 혈중(血中) corticosterone에 미치는 효과(效果))

  • Nam Yeo-Jeong;Lee Tae-Hee
    • Herbal Formula Science
    • /
    • v.10 no.1
    • /
    • pp.157-167
    • /
    • 2002
  • This study was performed to investigate what effect the taste and quality of drugs would have on the cold and heat mechanisms of human body. We administered Hwangryeunhaedok-tang composed of bitter-tasted, cold-qualified drugs and Gungangbuza-tang composed of spice-tasted. hot-qualified drugs, respectively to the mice 1 hr before exposure to heat stress or cold stress. Plasma corticosterone level of mice was measured. The results were as follows: 1. The elevated corticosterone level in the mice exposed to heat stress was significantly decreased after administration of Gungangbuza-tang but there was no decrease after administration of Hwangryeunhaedok-tang. 2. The elevated corticosterone level in the mice exposed to cold stress was significantly decreased after administration of Hwangryeunhaedok-tang but there was mild decrease after administration of Gungangbuza-tang. 3. When the doses, 3g/kg and 1g/kg were administerd to mice exposed to heat stress. both dose showed significant decrease of corticosterone level and the dose. 3g/kg was more effective. However, in the mice exposed to cold stress, the dose, 3g/kg showed mild decrease and 1g/kg showed significant decrease. These data suggested that HW decreased the plasma corticosterone level in the mice exposed to cold stress and GB also decreased the plasma corticosterone level in the mice exposed to heat stress. In conclusion, our study revealed that the taste and quality of drugs controled the cold and heat mechanism of human body.

  • PDF

Chromosome Aberrations and Sister Chromatid Exchanges of Hospital Workers Exposed to Radiation (방사선취급 병원근무자들의 염색체이상 및 자매염색분체교환 빈도)

  • Cha, Ae-Ri;Kim, Mi-Sun;Hwang, In-Kyung;Lee, Su-Ill;Cho, Byung-Mann;Kim, Don-Kyoun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.616-627
    • /
    • 1998
  • In order to evaluate the cytogenetic hazard among hospital workers potentially exposed to low dose of radiation, the analysis of chromosome aberrations(CA) and sister chromatid exchanges(SCE) in lymphocytes were performed in 79 hospital workers and 79 non-exposed workers. The mean frequency of chromosomal exchange and deletion(respectively, $0.20\times10^{-2}/cell\;and\;0.39\times10^{-2}/cell$) in the exposed group were significantly higher than those$(0.07\times10^{-2}/cell\;and\;0.23\times10^{-2}/cell)$ in control group. The frequency of sister chromatid exchanges was 5.04/cell in the control vs. 6.57/cell in the exposed group. There were also significant differences in the mean frequencies of CA and SCE adjusted for age, sex, smoking, drinking between two groups. There were no evidence of significant increase of CA and SCE according to the department or duration of employment. But the frequency of cells having chromosome aberration was significantly higher in the exposed group than in the control group related to duration of employment. There was no dose-effect relationship between the cumulative doses and the frequency of CA and SCE. But in the case of last 1 yr cumulative dose, there were evidence of significant dose-dependant increase of chromosome type CA and percentage of cells with aberration. The result suggest that there is cytogenetic hazard in risk group like hospital workers handling low dose radiation. And the analysis CA and SCE are useful biological indicators for the exposure of low dose level of radiation.

  • PDF