• 제목/요약/키워드: Exposed concrete

검색결과 904건 처리시간 0.024초

해수에 방치한 콘크리트 시험체 중의 철근 부식 추정 (The Estimation of Steel Corrosion in Concrete Specimen Exposed under Seawater)

  • 문한영;김성수;류재석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.85-90
    • /
    • 1993
  • This study was performed for the purpose of obtaining the fundamental data to establish the criterion of concrete deterioration and presuming steel corrosion of concrete structures under the environment of seawater. It was exposed in seawater for 1 year that steel was embedded in the concrete specimen. The diffusion coefficients of concrete, corrosion potential and steel corrosion were considered. The results show that corrosion potential is reduced according to steel corrosion and corrosion area ratio is correlative with diffusion coefficients of concrete.

  • PDF

골재노출 콘크리트의 소음 저감 특성에 대한 연구 (A Study on the Properties of Noise Reduction on the Exposed Aggregate Concrete)

  • 문한영;하상욱;양은철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.119-124
    • /
    • 2002
  • Generally, Portland cement concrete(PCC) pavements have the advantage of durability and superior surface friction when compared to most dense-graded asphalt. However, It is known that PCC pavements create more noise than asphaltic surfaces due to the noise from interaction of tire and pavement surface. Recently exposed aggregate concrete(EAC) pavement was sugested to reduce traffic noise. So in this paper, we considered several materials and mixture proportions for proper depth of exposed aggregate which was measured by the sand patching test, and then according to those relationships, we tried to find out dosage of retarding agents and optimum mixture proportions for expecting good effects to noise reduction. It were also evaluated sound level at every conditions of surface texture as like depth of aggregate exposed, profile peak, distance of aggregate and types of aggregate.

  • PDF

고온에 노출된 철근콘크리트 보의 역학적 특성에 관한 실험연구 (Experimental Study on the Mechanical Behavior of Reinforced Concrete Beams Exposed to High Temperature)

  • 최광호;이중원;음영훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.127-130
    • /
    • 2005
  • The purpose of this study is to investigate the flexural behavior of reinforced concrete beam members exposed to high temperature. In order to study the flexural behaviors, the 17 specimens have been tested with variables of reinforcement ratios($0.5\rho_{max},\rho_{min}$), heating conditions(nonheating, 400$^{circ}C$, 600$^{circ}C$, 800$^{circ}C$ heating and 1 hour preservation) and loading state(stressed and residual state). The results show that the stiffness and strength of specimens are lower when they are exposed to higher temperature and the pattern of crack and color of specimens exposed to fire are different from ordinary concrete members.

  • PDF

고온에 노출된 고강도 콘크리트 기둥의 수치해석 (Numerical analysis of high-strength concrete exposed elevated temperature)

  • 서연주;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.21-24
    • /
    • 2005
  • A computational analysis of hygro-thermal and mechanical behaviour of concrete column at high temperature is presented. The objective of this study is to develop a finite difference model that simulates coupled heat and transport phenomena in reinforced concrete structures exposed to rapid heating conditions such as fires. The theoretical basis for the integrated finite difference method is presented to describe a powerful numerical technique for solving of fluid flow in porous media. The numerical results predict the phenomena of 'moisture clog' and the explosive spalling of concrete under fire. The investigations show that high-strength concrete(HSC) and normal-strength concrete(NSC) exposed to high temperature have different pore pressure buildup dependent on porosity, permeability and moisture contents. HSC has more possibility than NSC on spalling.

  • PDF

Corrosion behavior of concrete produced with diatomite and zeolite exposed to chlorides

  • Gerengi, Husnu;Kocak, Yilmaz;Jazdzewska, Agata;Kurtay, Mine
    • Computers and Concrete
    • /
    • 제19권2호
    • /
    • pp.161-169
    • /
    • 2017
  • Chloride induced reinforcement corrosion is widely accepted to be the most frequent mechanism causing premature degradation of reinforced concrete structures. The electrochemical impedance of reinforcing steel in diatomite- and zeolite-containing concrete exposed to sodium chloride was assessed. Chemical, physical and mineralogical properties of three concrete samples (20% diatomite, 20% zeolite, and a reference containing neither) were correlated with corrosion investigations. The steel-reinforced samples were exposed to 3.5% NaCl solution for 500 days, and measured every 15 days via EIS method. Results indicated that porosity and capillary spaces increase the diffusion rate of water and electrolytes throughout the concrete, making it more susceptible to cracking. Reinforcement in the reference concrete was the most corroded compare to the zeolite and the diatomite samples.

Residual properties of high-strength fiber reinforced concrete after exposure to high temperatures

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • 제24권1호
    • /
    • pp.63-71
    • /
    • 2019
  • Thermal energy from high temperatures can cause concrete damage, including mechanical and chemical degradation. In view of this, the residual mechanical properties of high-strength fiber reinforced concrete with a design strength of 75 MPa exposed to $400-800^{\circ}C$ were investigated in this study. The test results show that the average residual compressive strength of high-strength fiber reinforced concrete after being exposed to $400-800^{\circ}C$ was 88%, 69%, and 23% of roomtemperature strength, respectively. In addition, the benefit of steel fibers on the residual compressive strength of concrete was limited, but polypropylene fibers can help to maintain the residual compressive strength and flexural strength of concrete after exposure to $400-600^{\circ}C$. Further, the load-deflection curve of specimen containing steel fibers exposed to $400-800^{\circ}C$ had a better fracture toughness.

동결융해 작용을 받은 콘크리트의 공극구조 및 염화물 침투저항 특성 (Characteristics of Pore Structure and Chloride Penetration Resistance of Concrete Exposed to Freezing-Thawing)

  • 최윤석;원민식;이성태;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.73-81
    • /
    • 2012
  • 콘크리트 구조물은 일반적으로 동결융해 작용을 받는 조건에 노출되고, 이러한 동결융해작용은 콘크리트의 공극구조를 변화시키고, 콘크리트의 내구성을 저하시킬 우려가 있다. 따라서 본 연구에서는 동결융해작용에 의한 콘크리트 내부공극구조 변화와 동결융해작용을 받은 콘크리트의 내구특성을 평가하고자 하였다. 실험결과, 기존의 동결융해 평가기법에 따르면 모든 배합에서 우수한 내구성능을 나타내었으나, 동결융해 작용에 노출됨에 따라 50~100nm 크기의 공극이 크게 증가하며, 콘크리트 염화물침투저항성이 저하하였다. 수중양생 콘크리트의 공극구조와 염화물 침투저항성은 선형관계를 보이지만, 동결융해작용을 받으면 내부공극구조의 변화로 선형관계가 저하하였다. 동결융해작용과 염화물침투를 동시에 받는 구조물의 내구성 평가기준에 대한 재검토가 필요할 것으로 판단된다.

Deterioration of tensile behavior of concrete exposed to artificial acid rain environment

  • Fan, Y.F.;Hu, Z.Q.;Luan, H.Y.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.41-56
    • /
    • 2012
  • This study is focused on evaluation of the tensile properties of concrete exposed to acid rain environment. Acid rain environment was simulated by the mixture of sulfate and nitric acid in the laboratory. The dumbell-shaped concrete specimens were submerged in pure water and acid solution for accelerated conditioning. Weighing, tensile test, CT, SEM/EDS test and microanalysis were performed on the specimens. Tensile characteristics of the damaged concrete are obtained quantitatively. Evolution characteristics of the voids, micro cracks, chemical compounds, elemental distribution and contents in the concrete are examined. The deterioration mechanisms of concrete exposed to acid rain are well elucidated.

염해환경하 콘크리트의 철근방식공법 연구 (Research for Corrosion Protection System of Embedded steels for Reinforced Condrete Exposed to Chloride Environments.)

  • 문홍식;류금성;정영수;박희상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.281-284
    • /
    • 1999
  • Bridge structure is known as one of important infrafacilities for comfortable human life. Recent long-span bridges, such as Kwang-Ahn Grand bridge, S대-Hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the seaside without in-depth consideration of concrete durability problems, It is in particular noted that corrosion of reinforcement steel in concrete is very important for the durability enhancement of concrete structures. The objective of this experimental study is to investigate the corrosion degree of reinforcing steels in concrete specimens which are exposed to cyclic wet and dry saltwaters, and then to develop pertinent corrosion protection system such as rational cover depth, corrosion inhibitors, cathodic system for reinforced concrete bridges exposed to marine environment.

  • PDF

골재노출 콘크리트의 지연제 효과에 대한 검토 (Effects of retarder on manufacturing Aggregate Exposed Concrete)

  • 문한영;하상욱;양은철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.647-650
    • /
    • 2001
  • The traffic noise from automobiles have been causing so serious problems in urban areas that the study and solutions to reduce noise and air pollution have been required. In general, Portland cement concrete(PCC) pavements have the advantage of durability and superior surface friction when compared to most dense-graded asphalt. However, data collected to date generally show PCC pavements to create more noise than asphaltic surfaces. Therefore, recent research has shown some new concrete pavement textures to be worth further examination. Exposed Aggregate Pavements have also been evaluated for noise impacts. This PCC surface is accomplished by brushing the surface of the plastic concrete to expose the aggregate, increasing the macro texture. In this study, in order to manufacture Aggregate Exposed Concrete for low noise pavements, we considered the effects of retarder agents according to dosage and curing conditions. So we tried to find out relationship between textures of surface and effects of retarder.

  • PDF