• Title/Summary/Keyword: Explosions

Search Result 374, Processing Time 0.03 seconds

Study on the Evaluation of Radiant Heat Effects of Oil Storage Tank Fires Due to Environmental Conditions (환경조건에 따른 유류저장탱크 화재의 복사열 영향 평가 연구)

  • Lee, Jeomdong;Ryu, Juyeol;Park, Seowon;Yoon, Myong-O;Lee, Changwoo
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.72-78
    • /
    • 2020
  • In this paper, the risk of damages to humans and properties due to fire explosions in gasoline storage tanks is identified, and the effects of radiant heat on adjacent tanks are evaluated to present the necessary area to secure safety. A simulation was conducted to evaluate the effect of radiant heat (Maximum emission) on adjacent tanks in an oil storage tank fire due to environmental conditions (Wind speed and temperature) in the Northern Gyeonggi Province. The result indicated that the radiant heat released in the fire of an oil storage tank was increased by approximately 1.9 times by the maximum wind speed and the difference occurred in the range of 700~800 kW by the maximum temperature. If a storage tank fire occurs, securing approximately 34.4 m of holding area is necessary. In the future, evaluating the radiant heat emitted by the fire of gasoline storage tanks will be required by applying various environmental conditions, and through this, research on specific and quantitative holding area is required.

The Continuity of Operation (COOP) Application to a Local Government for Disaster Risk Reduction

  • Jang, Young-Jin;Wang, Won-joon;Jung, Jae-Wook;Seo, Yong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.157-166
    • /
    • 2019
  • Globally, various disasters such as typhoons, floods, earthquakes, fires, explosions have caused work to be halted. If there is a large-scale disaster at public institutions in charge of major national affairs and their works are interrupted, not only will there be property damage, but there will also lead to a decline in national credibility and direct and indirect impacts on the people. Therefore, it is necessary to ensure continuity of operation by minimizing the interruption period of critical operations due to disasters. Overseas advanced countries such as the United States and Japan developed guidelines for Continuity of Operation (COOP) to prevent unexpected work disruptions caused by disasters. Recognizing the necessity of COOP in South Korea, a relevant law has been newly established in 「the Framework Act on the Management of Disasters and Safety」 to enable public institutions to establish the COOP in response to this situation. In this study, the definition, the necessity and overseas cases of COOP were investigated and described. Using the templates developed by these results, operational impact analysis, risk assessment, operational continuity strategies and operational continuity procedures were applied to "A" City Hall in Gyeonggi-do province and those results were described. The objective of this study is to substantially contribute to the introduction of COOP to local governments through their pilot application and implications of COOP.

Reliability Analysis on Safety Instrumented System by Using Safety Integrity Level for Fire.Explosion Prevention in the Ethyl Benzene Processes (Ethyl Benzene 공정에서 화재.폭발방지를 위하여 안전건전성수준을 이용한 안전장치시스템의 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo;Lee, Su-Kyoung
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this work is to analyze quantitatively if the safety instrumented system(SIS) like the pressure safety valves(PSV) in the processes of ethyl benzene plant have been designed relevantly to the safety integrity level because overpressure in the benzene or ethyl benzene columns causes the explosive reactions, fires and reactor explosions. The safety integrity level(SIL) 3 has been adopted as a target level of SIS based on the general data of the Probability of Failure on Demand of PSV, $1.00E-4{\sim}1.00E-3$. The standard model of the reliability has been set up and then the fault tree analysis of it has been carried out to get the PFD of SIS, and the results show 8.97E-04, 5.37E-04, 5.37E-04 for benzene prefractionator column, benzene column and EB column, respectively. Thus, we conclude that the SIS is designed to fulfill the condition of SIL3, and when the partial stroke test for the control valve are carried out every sixth month, the SIS of each column is expected to increase its reliability up to $22{\sim}27%$.

Explosion Properties and Thermal Stability of Reactive Organic Dust (반응성 유기물 분진의 폭발특성과 열안정성)

  • Han, Ou-Sup;Han, In-Soo;Choi, Yi-Rac;Lee, Keun-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.7-14
    • /
    • 2011
  • Using 20 L spherical explosion vessel and differential scanning calorimeter (DSC), an experimental investigation was carried on explosion characteristics and thermal decomposition of some reactive organic dust. As the result, the minimum explosion concentration of Benzoyl peroxide (BPO), Phthalic anhydride (PA) and 1-Hydroxybenzotriazol (HBT) exist between 10 and 15 g/$m^3$, which indicates that their explosion sensitivity are high. The maximum Kst values of HBT, PA and 97 % BPO are 251, 146 and 80 [$bar{\cdot}m/s$], respectively and the explosion severity of HBT is the explosion class of St-2. The flame velocity was also calculated from the combustion time of dust and flame arrival time to estimate the flame propagation characteristics in a closed vessel. The decomposition temperature and heat of decomposition reaction for 97 % BPO and HBT are $107^{\circ}C$ (1025 J/g), $214^{\circ}C$ (1666 J/g), respectively and it was found that these low decomposition temperature and high released heat affect the explosion characteristics.

Characteristics of Flames Propagating Through Combustible Particles Concentration in a Vertical Duct (수직 배관 내의 농도변화에 따른 분진폭발 특성)

  • Han, Ou-Sup;Han, In-Soo;Choi, Yi-Rac;Lee, Jung-Suk;Lee, Su-Hee
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • We investigated experimentally the properties of dust explosion through lycopodium particle clouds in a duct to provide the fundamental knowledge. Propagating dust flames in the vertical duct of 120 cm height and 12 cm square cross-section were observed by digital video camera and flame front is visualized using by PIV(Particle Image Velocimetry) system. As the result, when the same average dust concentration existed in the vertical duct, downward flame propagation was faster than the upward flame propagation, its rate increased with dust concentration in 300g/$m^3$. Post flames were caused by the ignition of unburned particles which flowed into the rear region of flame from passage between flame and duct wall, and they generated regardless of duct condition. Also, it was found that appearance frequency of post flames during dust flame propagations increased with the increase of dust concentration.

Minimum Burning Pressure of Emulsion Explosives (에멀젼폭약의 최소연소압력에 관한 연구)

  • 이승찬;고재순;이영호
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2004
  • It is well accepted that modem emulsion explosives are intrinsically much less sensitive than traditional products such as dynamites or black powder. However, they have still been involved in a significant number of accidental explosions. In October 1975, Canadian Research, Limited's, Energetic Research Laboratory in Quebec exploded. Although explanations for the incident varied, one logical explanation was that the pump used in transporting the emulsion dead headed, thereby turning mechanical work in to frictional heating under a zero flow rate. There is a minimum pressure required for combustion(MBP) to propagate in emulsion explosives. A stable deflagration may lead to a deflagration-to-detonation transition(DDT) in emulsion explosives. Tests were also performed on sensitized sampled consisting of 6 to 21% waters as well as 1 to 11% aluminium powder. It was founded the emulsion explosives consisting of 6% waters had the lowest minimum homing pressure(MBP) of 3 bar, and the 21% waters were unable to achieve sustained homing at pressures as high as 100 bar. The aluminium contained explosives tested here displayed a MBP higher than that of without emulsion. It appears that this test may offer a firm ground for the classification of emulsion explosives in view of the regulating the hazards associated with the various process used for their manufacturing and transport.

Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부화재에 따른 온도 및 속도분포 해석)

  • Kim, Yeob-Rae;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.19-25
    • /
    • 2013
  • The fire took place in the synthetic heat transfer fluid boiler. This study uses simulation to investigate the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is more or less unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120 kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The simulation shows that the temperature is $767^{\circ}C$ in the low part of the third pass. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. The temperature rises to $183^{\circ}C$ in the low part of the burner. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner.

Dynamic behavior Simulation for Explosion in Two-lane Horseshoe Shaped Tunnel (2차로 마제형 터널 내 폭발 시 동적 거동 시뮬레이션)

  • Shim, Jaewon;Kim, Nagyoung;Lee, Hyunseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.5
    • /
    • pp.23-33
    • /
    • 2020
  • As the scale of the economy expands, the number of cases of damage in enclosed spaces such as tunnels is increasing due to the accident of transportation vehicles of dangerous substances such as explosive flammable materials that have increased rapidly. In the case of road tunnels in particular, in the aspect of protection against the long-winding trend and the environment in the downtown area, the number of cases of passing through the downtown area increases, and securing the safety of structures against unexpected extreme disasters such as explosions during tunnel passage is very urgent. For this reason, developed countries are already conducting a review of internal bombardment, but there are almost no evaluation and countermeasures for explosion risk in Korea. Therefore, in this study, in order to evaluate the explosion safety of road tunnels, a boiling liquid explosive explosion (BLEVE), which is considered to have the greatest explosion load among vehicles driving on the road, is set as a reference explosion source, and the equivalent TNT explosion load is used for simulation of the explosion. A method of conversion was presented. In addition, by applying the derived explosion load, dynamic behavior simulation was performed by assuming various variables for the tunnel, and the explosion safety of the tunnel was analyzed.

Dynamic Structural Response Characteristics of Stiffened Blast Wall under Explosion Loads (폭발 하중을 받는 보강된 방폭벽의 동적 구조 응답 특성에 관한 연구)

  • Kim, Sang Jin;Sohn, Jung Min;Lee, Jong Chan;Li, Chun Bao;Seong, Dong Jin;Paik, Jeom Kee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.5
    • /
    • pp.380-387
    • /
    • 2014
  • Piper Alpha disaster drew attention to the damage likely to arise from explosions and fires on an offshore platform. And great concerns have been increased to prevent these hazards. Blast wall is one of the passive safety systems; it plays a key part of minimizing the consequences. However, a buckling due to explosion loads is a factor which can reduce the strength of blast wall. The buckling often occurs between web and flange at the center of blast wall. This study aims to find a solution for reinforcing its strength by installing a flat plate at the spot where the buckling occurs. First of all, ANSYS finite element method is adopted to numerically compute the structural resistance characteristic of blast wall by using a quasi-static approach. Sequentially, the impact response characteristics of blast wall are investigated the effect on thickness of flat plate by using ANSYS/LS-DYNA. Finally, pressure-impulse diagrams (P-I diagram) are presented to permit easy assessment of structural response characteristics of stiffened blast wall. In this study, effective use is made to increase structural intensity. of blast wall and acquired important insights have been documented.

Crustal Structure of the Korean Peninsula by Inverting the Rravel Times of First-arrivals from Large Explosions (대규모 발파자료 초동주시 역산을 통한 한반도 지각 속도구조 연구)

  • Kim, Ki-Young;Hong, Myong-Ho;Lee, Jung-Mo;Moon, Woo-Il;Baag, Chang-Eob;Jung, Hee-Ok
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.45-48
    • /
    • 2005
  • In order to investigate the velocity structure of the southern part of the Korean peninsula, exploded seismic signals were recorded for 120 s along a 294-km WNW-ESE line and 150 s along a 335-km NNW-SSE line in 2002 and 2004, respectively. Velocity tomograms were derived from inverting first arrival times. One-dimensional velocity models derived by joint analyses of teleseismic receiver functions and surface wave dispersion at several stations near the profiles were uesd to build initial models. The raypaths indicate several midcrust interfaces including ones at approximate depths of 2.0 and 14.9 km with refraction velocities of approximately 6.0 and 7.1 km/s, respectively. The deepest significant interface varies in depth from 30.8 km to 36.1 km. The critically refracting velocity varies from 7.8 to 8.1 km/s along this interface which may correspond to the Moho discontinuity. The velocity tomograms show (1) existence of a low-velocity zone centered at 6-7 km depth under the Okchon fold belt, (2) extension of the Yeongdon fault down to greater than 10 km, and (3) existence of high-velocity materials under the Gyeongsan basin whose thickness is less than 4.2 km.

  • PDF