• Title/Summary/Keyword: Explosion-Proof

Search Result 78, Processing Time 0.025 seconds

Explosion Proof of Fiber Reinforced Cement Composite Panel subjected to Contact Explosion (접촉폭발에 의한 섬유보강 시멘트 복합체의 방폭성능)

  • Kim, Yun-Hwan;Kim, Gyu-Yong;Kim, Hong-Seop;Lee, Bo-Kyeong;Lee, Sang-Gyu;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.128-129
    • /
    • 2016
  • This paper evaluates experimentally the explosion proof of fiber reinforced cement composite(FRCC) panels with various fibers of 2 % volume fraction subjected to contact explosions using an emulsion explosive. As a results, the proportion of the total damage in FRCC panels is not biased scabbing on the rear side with contrast to plain panels, which means that the local damage of FRCC panels was significantly controlled. The experimental results presented useful information for prediction of limited thickness on the local damage subjected to contact explosions through comparison with existing damage evaluation prediction equations.

  • PDF

A Study on the Safe Gap for Explosion-proof (내압방폭을 위한 Safe Gap의 측정에 관한 연구)

  • Oh Kyu-hyung
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1997
  • In case of using the electrical apparatus in the hazardous atmosphere which exist flammable gas mixtures, There is a dangerosity of gas explosion accident by the electrical spark. The most general method to prevent the explosion by the spark is to use the flame-proof type electrical apparatus to isolate the ignition source. from the flammable atmosphere. But actualy it is impossible to isolate the ignition sources from the atmosphere. So it was needed to find the safe gap which prevent ignition of flammable atmosphere by transmission of flame or heat when a flammable gas mixture exploded inside the apparatus. In this study we tried to find the maximum experimental safe gap(MESG) of $H_2$-air, and $CH_4$-air mixtures by using the 8 litre spherical vessel with 25mm flange. The experiment parameter were ignition position, concentration and initial pressure before explosion. From the experiment the ignition position was affected to the MESG. MESG value was minimum near the stoichiometric concentration of gas mixtures, and according to the increase of initial pressure MESG was decreased.

  • PDF

Topology Optimization of Reinforcement Pattern for Pressure-Explosion Proof Enclosure Door in Semiconductor Manufacturing Process (위상최적화 기법을 이용한 반도체 공정용 압력방폭형 외함 도어의 보강 패턴 최적화)

  • Yeong Sang Kim;Dong Seok Shin;Euy Sik Jeon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.56-63
    • /
    • 2023
  • This paper presents a method using finite element analysis and topology optimization to address the issue of overdesign in pressure-explosion proof enclosure doors for semiconductor manufacturing processes. The design conducted in this paper focuses on the pattern design of the enclosure door and its fixation components. The process consists of a solid-filled model, a topology optimization model, and a post-processing model. By applying environmental conditions to each model and comparing the maximum displacement, maximum equivalent stress, and weight values, it was confirmed that a reduction of about 13% in weight is achievable.

  • PDF

A study on the Prediction of Explosion Risk for the Low Pressure Natural Gas Facilities with Different Explosion Conditions (저압 도시가스 사용설비의 누출 조건에 따른 폭발 위험 분위기 형성 범위 예측에 관한 연구)

  • Han, Sangil;Lee, Dongwook;Hwang, Kyu-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.59-65
    • /
    • 2016
  • It is imperative to use suitable explosion proof equipments to prevent explosion in different gas facilities. There is no technical standard for the classification of hazardous areas though standard of explosion proof is regulated. In this study, we have adopted Industrial Standard KS to develop the methodology for the prediction of the explosion risk in the natural gas facility with low pressure using the important factors including hole size, hypothetical volume, validation of ventilation effectiveness. The applicability of the developed methodology was evaluated by the comparison with the data obtained from experiments of natural gas explosion.

Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V (AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석)

  • Jeong, Min-Joo;Her, In-Sung;Kang, In-Cheol;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof (방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Jo, Young-Do;Kwon, Jeong-Rock;Ahn, Sang-Guk;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we developed an explosion proof type and portable combustible gas leak detector and proposed an algorithm to improve the accuracy for measuring gaseous concentrations. The nation's first we developed an infrared gas leak detector with explosion proof standard(Ex d ib) and improved measuring accuracy by using linearization recursion equation and 2nd Lagrange interpolation polynomial. Together, we advanced their performances and added their easy functions after investigating field demands. To compare our and other company's detectors, we performed measurement tests with eight standard gases made by Korea Gas Safety Corporation. We demonstrated the excellence of our instruments in measuring accuracy other than detecters through experimental results.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • v.61 no.3
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

Measures to Prevent Recurrence through the Analysis of an Explosion Case at Ammonia Refrigeration Facilities (암모니아 냉동시설의 폭발사례 분석을 통한 재발방지대책)

  • Ryu, Young-Jo;Lee, Min-Kyung;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • In this study, we found that the release and dispersion of ammonia can create hazardous atmospheres using FLACS software. In General, ventilation or gas detector installations are recommended as preventive measures to control explosion incidents. However, the ventilation installations cannot be applicable to the refrigeration facility that uses ammonia as refrigerating medium, because the freezing room should be sealed. From the accident investigation of the explosion case, we suggested that all electronic devices were needed to be switched by explosion proof devices, and communication facility was also needed to be installed to announce to all employees within a building in case alert condition like ammonia releases occurred.