• Title/Summary/Keyword: Experiments with Mixtures

검색결과 251건 처리시간 0.022초

워터펌트 내에 있는 임펠러의 침식.부식에 관한 연구 (Study on the erosion-corrosion damages of pump impeller)

  • 김재욱;임희창;임우조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.102-107
    • /
    • 2007
  • The steel impeller placed in a water pump has been studied with the aim to understand corrosion phenomena on the surface responsible for reducing the pumping efficiency of water inside cooling system. This preliminary experiment includes a period (around 1 month) observation with a powered microscope and weight measurements. The experiments are carried out at different conditions of water and mixtures of water and coolants, based on the water contents of 25%, 50%, 75%, and 100% water (pure tap water). From the visual results of microscopy, most of the steel surface is fitted and clear rusty or corrosion phenomena are noticeable as time goes. In addition, the weight loss of the sample specimen submerged in the water is linearly increased, whereas those in the mixtures of water initially gain weight and become almost constant.

  • PDF

메탄-공기 예혼합기의 열면점화에 미치는 촉매반응 및 자연대류의 영향 (Effects of Catalytic Reaction and Natural Convection on the Hot Surface Ignition of Methane-Air Mixtures)

  • 김형만;정종수
    • 한국연소학회지
    • /
    • 제2권1호
    • /
    • pp.29-38
    • /
    • 1997
  • In this study, the experimental and numerical investigations of the ignition of methane-air mixtures by a electrically heated wire have been carried out. In order to define the initial condition and make the analysis simple, the following control unit was developed; which heats the wire to the setting temperature in a very short time, and maintains the wire temperature constant until ignition. Experiments with the feedback control have been performed using nickel and platinum wires in normal gravity and microgravity. From experimental results, ignition temperatures in normal gravity are higher than those in microgravity, however, the dependences of ignition temperature on equivalence ratio are not affected by natural convection. Numerical calculations, including catalytic reaction for platinum, have been performed to analyze the experimental results in microgravity. Numerical results show that reactants near platinum wire are consumed by catalytic reaction, therefore, the higher temperature is needed to ignite the mixture with platinum wire.

  • PDF

펌프 임펠러의 부식 파손에 대한 연구 (Study on the Corrosion Damages of Pump Impeller)

  • 김재욱;임희창;권오붕;배대석
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.46-52
    • /
    • 2009
  • The steel impeller placed in a water pump has been studied with the aim to understand corrosion phenomena on the surface responsible for reducing the pumping efficiency of water inside cooling system. This preliminary experiment includes a period (over 5 months) observation with a powered microscope and weight measurements. The experiments are carried out at different conditions of water and mixtures of water and coolants, based on the water contents of 25%, 50%, 75%, and 100% water (pure tap water). From the visual results of microscopy, most of the steel surface is fitted and clear rusty or corrosion phenomena are noticeable as time goes. In addition, the weight loss of the sample specimen submerged in the water is linearly increased, whereas those in the mixtures of water initially be constant and then gain weight linearly.

  • PDF

A Study on Pressure Drop Characteristics of Refrigerants in Horizontal Flow Boiling

  • Lim, Tae-Woo;Han, Kyu-Il
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.758-765
    • /
    • 2003
  • An experimental investigation on the flow pattern and pressure drop was carried out for both an adiabatic and a diabatic two-phase flow in a horizontal tube with pure refrigerants R134a and R123 and their mixtures as test fluids. The observed flow patterns were compared to the flow pattern map of Kattan et al., which predicted well the present data over the entire regions of mass velocity in this study. The measured frictional pressure drop in the adiabatic experiments increased with an increase in vapor quality and mass velocity These data were compared to various correlations proposed in the past for the frictional pressure drop. The Chisholm correlation underpredicted the present data both for pure fluids and their mixtures in the entire mass velocity range of 150 to 600 kg/m$^2$s covered in the measurements, white the Friedel correlation was found to overpredict the present data in the stratified and stratified-wavy flow region, and to underpredict in the annular flow region.

SCP공법 적용을 위한 굴패각-모래 혼합토의 전단과 압축특성 (Shear Strength and Compressibility of Oyster Shell-Sand Mixtures for Sand Compaction Pile)

  • 윤길림;윤여원;채광석;김재권
    • 한국지반공학회논문집
    • /
    • 제20권9호
    • /
    • pp.17-23
    • /
    • 2004
  • 굴양식장에서 폐기물로 처리되는 굴패각을 지반재료로 이용하기 위해서 굴패각-모래 혼합토의 강도 및 변형 특성에 대해 조사하였다. 타설된 모래다짐말뚝 재료의 강도는 표준관입시험(SPT)에 의해 현장에서 타설된 모래다짐말뚝 강도를 확인하는 것으로 되어있다. 그러나 모래는 표준관입시험에서 얻어진 N값과 내부마찰각의 관계에 대해 상당히 밝혀져 있으나, 굴패각-모래 혼합토에 대해서는 N값과 내부마찰각의 관계가 연구되어 있지 않다. 본 연구논문에서는 단위체적중량이 다양한 굴패각-모래 혼합토를 대형 모형토조에서 표준관입시험 및 대형 직접전단시험을 수행하여 N값, 단위체적중량, 내부마찰각의 상호 상관성을 제시하였다. 이러한 연구결과는 현장에서 표준관입시험을 통한 굴패각-모래 혼합토의 강도 평가가 가능하게 했으며 구속압축시험을 통하여 체적압축계수를 산정하고 혼합토의 예상침하량을 계산할 수 있게 하였다.

포도상구균에 대한 키토산의 항균성 측정을 위한 실험조건의 적정화 (Optimization of Experimental Conditions for the Chitosan Antibacterial Activity Test against Staphylococcus aureus)

  • 한영숙
    • 대한가정학회지
    • /
    • 제42권3호
    • /
    • pp.145-158
    • /
    • 2004
  • Experimental conditions for evaluating chitosan antibacterial activities were established. The chitosan antibacterial activities were measured against the Staphylococcus aureus and evaluated for their application to antibacterial textile finishing. The strain of Staphylococcus aureus used in this experiments was KCTC 1916. The chitosan antibacterial activities were estimated from the bacterial densities or %reduction of bacteria in chitosan solutions and bacterial culture mixtures after incubation under specific conditions. Six parameters as follows were evaluated to optimize the experimental conditions for measuring antibacterial activities. The different combinations of mixtures according to the different ratios of chitosan solutions to the bacterial cultures showed different antibacterial activities. However, the chitosan antibacterial activities could be evaluated by comparing the data obtained from the same combinations of mixtures. The solvent influence on the chitosan solution antibacterial activities could be eliminated using control solution containing the same concentration of acetic acid. The initial pH of the chitosan -bacterial mixtures also affected the chitosan antibacterial activity; at a higher pH, higher activity in terms of %reduction of bacteria was observed. In case of the bacterial solution without either the acetic acid or chitosan, the initial pH of the solution did not significantly affect bacterial growth. The % reduction of bacteria increased when contact times of bacteria with chitosan in the chitosan -bacterial mixture were expended upto 24 hours. However, the chitosan antibacterial activities could be successfully evaluated at contact time 0 where the chitosan-bacterial mixture was plated immediately after mixing and incubated to measure the bacterial number to 24 hours. Evaluating %reduction of bacteria in the test mixtures after incubation were not changed when the inoculated bacterial concentrations were 2.3${\times}$10$\^$0/ml to 2.3${\times}$10$\^$6/ml. The optimal range of incubation time of the petri-Dish after plating the chitosan-bacterial mixture was 24 to 72 hours depending on the antibacterial activities of the test solutions.

비공비혼합냉매를 사용하는 열펌프의 응축열전달 특성 (Condensing Heat Transfer Characteristics on a Heat Pump System Using Non-Azeotropic Refrigerant Mixtures)

  • 박기원;오후규;김욱중
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1125-1133
    • /
    • 1995
  • Experiments were performed to investigate the condensing heat transfer characteristics of non-azeotropic mixtures of R-22 and R-114 in a heat pump system with a horizontal smooth tube as a condenser. The ranges of parameters, such as heating capacity, mass flow rate of refrigerant and quality were 780-3,480W, 24-71kg/h, and 0-1, respectively. The overall compositions of R-22 in a R-22/114 mixture were 25, 50, 75 and 100 per cent by wight. The results show that the overall condensing heat transfer coefficients for the mixtures were lower than the pure R-22 values. Local heat transfer coefficient of the pure R-22 was hghest at the top of the test tube. The local heat transfer coefficient of R-22/114 (50/50 wt%) at side and bottom of the test tube was higher than that at the top. From the obtained data, a prediction for the condensing heat transfer coefficients of the mixture was done based on the method of Fujii.

Development of Drainage Asphalt Mixture Using Large Size Aggregate and Its Performance on Test Pavement

  • Ogino Shoji;Ohmae Tatsuhiko;Matsumoto Yuki;Yamada Masaru
    • 한국도로학회논문집
    • /
    • 제8권1호
    • /
    • pp.107-117
    • /
    • 2006
  • Recently, there has been a remarkable trend of using aggregates at sizes smaller than 13 mm for drainage asphalt pavement (DAP) in order to reduce the noise generated between vehicle tires and road surface. These DAPs have their performance and durability seriously worsen after several years in-service due to the clogging of void space and the abrasion. This paper proposes the use of large size aggregates in porous asphalt mixtures to overcome these defects. Results of laboratory and field experiments on asphalt mixtures with several aggregate gradations are investigated and compared. The study focuses on advantages of DAP using large size aggregate and on particle size combinations containing no fine aggregates of size 2.36 mm or less, which have not been considered in current engineering practice.

  • PDF

Water purification from pesticides by spiral wound nanofiltration membrane

  • Bottino, A.;Capannelli, G.;Comite, A.;Ferrari, F.;Firpo, R.
    • Membrane and Water Treatment
    • /
    • 제2권1호
    • /
    • pp.63-74
    • /
    • 2011
  • A spiral wound nanofiltration (NF) membrane (GE Osmonics, DK 4040F) was used to remove pesticides from water. Several solutions of single pesticides and their mixtures were prepared. The pesticides initial concentration ranged from ca. 50 ng/L (single pesticide) to ca. 700 ng/L (as sum of 14 pesticides) and progressively increased with time since the NF experiments were carried out in a concentration mode up to a Volume Concentration Ratio, VCR = 10. Permeate flux and pesticides retention were evaluated as a function of the Volume Concentration Ratio. The permeate flux did not practically change by varying VCR. Pesticide retention was found to be around 97-98% both in the cases of single pesticide solutions and different mixtures of pollutants, and was not affected by the VCR. Pesticides concentration in permeate samples was found to be lower than the maximum concentration level fixed in European directive.

HFC125+Propane 혼합냉매의 기-액 평형에 관한 실험적 연구 (An Experimental Study of Vapor-Liquid Equilibrium for HFC12S+Propane Refrigerant Mixtures)

  • 강준원;박영무;유재석;이종화
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.563-571
    • /
    • 2003
  • The forty vapor-liquid equilibrium data of the binary system, HFC125+Propane, were measured between 273.15 and 313.15 K at 10 K interval and the composition range 0.2∼0.75, respectively. Experiments were performed in a circulation type apparatus in which the vapor phase was forced through the liquid phase. The composition at equilibrium were mea-sured by gas chromatography, and its response was calibrated using gravimetrically prepared mixtures. Vapor-liquid equilibrium data were calculated by using CSD equation of state and compared with the experimental data.