• 제목/요약/키워드: Experimental instrument

검색결과 471건 처리시간 0.023초

새롭게 개발된 치아청결기의 치태제거 및 치은염증에 대한 효과 (Plaque Removing Efficacy and Effect on Gingival Inflammation of Newly Developed Tooth Cleansing Instrument)

  • 한동관;방은경;김창성;최성호;조규성;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.475-484
    • /
    • 2003
  • Many tooth cleansing instruments and agents have been developed for removal of plaque, inhibition of plaque formation and reduction of gingival inflammation. The aim of this study was to evaluate the plaque control effect and the therapeutic effect of newly developed tooth cleansing instrument(Belloblanco(R)). 40 healthy subjects with gingivitis or early periodontitis were divided into two groups. Subjects in control group only used manual tooth brushing and in experimental group used manual tooth brush and additive tooth cleansing instrument(Belloblanco(R)). Additive tooth cleansing instrument was used once a week. At baseline scaling and tooth brushing instruction was performed. Probing depth, bleeding on probing, plaque index, gingival index were scored at baseline, 2weeks, 4weeks. Probing depth of control and experimental group were significantly reduced at 2 weeks, 4weeks, hut there were no differences between two groups(P<(0.05). Bleeding on probing, plaque index and gingival index of control and experimental group were significantly reduced at 2weeks and 4weeks and there was significantly more reduction in the experimental group than the experimental group than the control group(p<(0.05). From these finding. it can be conclude that newly developed tooth cleansing instrument(Belloblanco(R)) are effective on the removal of plaque and the reduction of gingival inflammation

다양한 구강위생기구를 이용하여 임플란트 표면의 Prophylaxis 시행시 표면형태의 변화분석 (Analysis of surface form change after performing prophylaxis procedure on implant surface using various oral hygiene instruments)

  • 이선구;임성빈;정진형;권상호
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.1-17
    • /
    • 2004
  • It is improtant that performing prophylaxis procedure on an infected implant surface in order to treat peri-implantitis should not change the surface roughness and composition, so that the surface can be recovered to almost same condition as initial implant surface. This thesis, therefore, studied an effect of various oral hygiene instrument on implant surface. A surface roughness measurement instrument and an infection electron microscope were used to observe a change on surface. The purpose of this study was to obtain a clinical guidelines during implant care and peri-implantitis treatment. The result were as follows 1. Ra values (surface roughness value) at experimental group 1, group 2, and group 5 were increased significantly as compared with comparison group(p<0.05). 2. When compared experimental group 1 with each experimental groups at which prohylaxis procedure was performed, mean values of Ra at experimental group 2, group 3, group 6, and group 7 were decreased significantly(p<0.05). 3. Mean value of Ra was lowest at experimental group 2, and highest at experimental group 2, and highest at experimental group 5. 4. Analysis of SEM showed that was significant surface change at experimental group 2, group 3, group 4, group 5, and group 6 as compared with comparison group(X1000). 5. Analysis fo EDX showed that a quantity of Ti on surface for experimental group 6 was very similar to that for comparison group. In conclusion, air-powder abrasive and citric acid, plastic instrument are safe methods to use for performing prophylaxis procedure on implant care or for cleaning and sterilization process on treatment of peri-implantitis, based on the result that those method did not affect implant surface roughness and Ti composition.

고등학생의 지구과학 탐구능력 측정을 위한 평가도구 개발 (The Development of a Test of Earth Science Inquiry Skills for High School Student)

  • 우종옥;이항로
    • 한국과학교육학회지
    • /
    • 제15권1호
    • /
    • pp.92-103
    • /
    • 1995
  • Since the late of 1960,s, the improvement of science inquiry skills has been one of the most important goals in secondary science education. To achieve this goal, it is essential to develop a valid and reliable instrument for evaluating science inquiry skills. The purpose of this study is to develop a valid and reliable instrument for evaluating science inquiry skills for high school students. The instrument is developed through R & D procedure, which includes two field trials of the instrument. This study has formed a clear definition of the elements of science inquiry skills (formulating a hypothesis, controlling variables, designing an experiment, numeric calculation, graphing experimental data, inference, determining relationship, determining causalities, predicting experimental results , drawing a conclusion, formulating a generalization or model), and established the goals of assessment and developed the items of assessment. The instrument, Test of Earth Science Inquiry Skills, consists of 33 items which measure 11 science inquiry skills. There are content-free items for each science inquiry skills. This study has selected 11 science inquiry skills which are considered appropriate for being evaluated by paper-and-pencil test with SIEI (Hur,1984). The content validity of items, objectivity of the scoring keys and clarity of the items were checked by six experienced specialists in science education. At the same time, the two field trials has been executed and produced the reliability of the instrument, item difficulty index, and the effectiveness of distracters. The first field trial was performed using a sample of 304 high school students, and the second one using a sample of 872 high school students. Because the content validity is 84 % and the reliability (K-R 20) is 0.84, the developed instrument in this study is considered valid and reliable. The difficulty index is 49.4 %, answer ratio 59.1 %, the discrimination index 0.47 and the effectiveness of distracters evenly distributed, which also suffice the criteria of good instrument. The developed instrument in this study can diagnosis the well-developed science inquiry skills and the ill-developed science inquiry skills of the students, and trace the degree of the improvement of science inquiry skills.

  • PDF

스키환자용 특수 슬관절보조기의 동특성 해석 (Dynamic Analysis of The Knee Brace for Ski Injuried Patient)

  • 최진영;김명회;장대진;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.893-898
    • /
    • 2003
  • A new type of the Expanded Knee brace was developed to measure the human knee joint. This instrument was composed of six parts, four arranged for two hinge joints and two pin joint , and two hinge for the expanded system. With a developed instrument, the experimental results obtained the data of Accelerometer, the experimental results obtained of the data FEM, the experimental results obtained the data of Motion Analysis and Force platform. Compared to earlier developed sports type knee brace, new instrument shows its convenience in application and accuracy in measurement.

  • PDF

Experimental Sensitivity Table Method for Precision Alignment of Amon-Ra Instrument

  • Oh, Eunsong;Ahn, Ki-Beom;Kim, Sug-Whan
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권3호
    • /
    • pp.241-246
    • /
    • 2014
  • The Amon-Ra instrument is the main optical payload of the proposed EARTHSHINE satellite. It consists of a visible wavelength instrument and an IR energy channel instrument to measure a global Earth albedo. We report a new sensitivity technique for efficient alignment of the visible channel instrument. Whilst the sensitivity table method has been widely used in the alignment process, the straightforward application of the method tends to produce slow process convergence because of shop floor alignment practice uncertainties. We investigated the error sources commonly associated with alignment practices and used them when estimating the Zernike polynomial coefficients. Aided with single center field wavefront error (WFE) measurements and their corresponding Zernike polynomial coefficients, the method involves the construction and use of an experimental, instead of simulated, sensitivity table to be used for alignment state estimations. A trial alignment experiment for the Amon Ra optical system was performed and the results show that 71.28 nm in rms WFE was achieved only after two alignment iterations. This tends to demonstrate its superior performance to the conventional method.

환경감수성 측정을 위한 검사 도구 개발과 이를 이용한 환경감수성 측정 - 중등학교 환경반을 대상으로 - (A Study on the Development and Measurement of Environmental Sensitivity among Middle School Environmental Class)

  • 이재붕;이두곤
    • 한국환경교육학회지:환경교육
    • /
    • 제19권3호
    • /
    • pp.138-149
    • /
    • 2006
  • The purpose of this study was to develop the environmental sensitivity(ES) measurement instrument and to apply for middle school students. The questionnaire was developed to evaluate ES. The developed questionnaire consists of 15 items in 5 categories. Each item of the instrument was developed through the conceptional analysis of the definition of ES. The 5 categories included natural environment, activity at natural environment, artificial environment, environmental pollution, environmental destruction. Data for this study were collected from 397 middle school students including 46 environmental class and 351 non-environmental class students. It was found that the developed instrument to measure ES was valid and reliable. Reliability coefficient, Cronbach $\alpha$ was 0.75. Using the developed instrument of ES, the ES was measured for the students of experimental group to which a inqury-based EE model was applied. The result was that the effect of ES of the students of the experimental group was not statistically significant. Futher research is needed related to the EE model based on the inquiry learning model and measurement of environmental sensitivity.

  • PDF

최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상 (Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery)

  • 박현준;원종석;박재흥
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

넓은 범위의 비오차를 갖는 전압변성기를 이용한 계기용 변성기 비교 측정 장치의 비오차 직선성 평가기술 (Evaluation Technique for Linearity of Ratio Error of Instrument Transformer Comparator Using Voltage Transformer with Wide Range of Error Ratios)

  • 정재갑;권성원;김한준;박영태;김명수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권2호
    • /
    • pp.66-70
    • /
    • 2005
  • Linearity of ratio error of instrument transformer comparator has been tested using wide ratio error voltage transformer(VT) with the ratio errors in the range of -3 % to 3 %. The technique is the method for evaluation of the linearity for instrument transformer comparator by comparing both the theoretical and experimental values in wide ratio error VT. The developed method has been successfully applied for calibration and correction in instrument transformer comparator belonging to industry.

저전압 대전류용 Forward-Flyback DC-DC 컨버터 (Forward-Flyback DC-DC Converter for the Low Voltage and High Current Applications)

  • 황선민;박승규;조인호;안태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.980-982
    • /
    • 2002
  • In this paper, we report the experimental results of the Forward-flyback DC-DC converter with current doubler and synchronous rectifier. The experimental converter, that has a output voltage 1.8V, output current 25A, maximum power of 45W, switching frequency of 290kHz and input voltage range of 36-75V, has been successfully implemented. As a result, in the entire voltage range the measured full load efficiency was above 82%, and the output voltage was regulated at 1.8V within ${\pm}$3% tolerance.

  • PDF

하수구 막힘 방지를 위한 모발 절단 분쇄 장치 개발 및 성능평가 (Development and Performance of Cutting and Crushing Instrument of Hair to Prevent Blocking U-trap in Home Drainage System)

  • 김동회
    • 대한환경공학회지
    • /
    • 제35권6호
    • /
    • pp.394-399
    • /
    • 2013
  • 가정 하수구의 주요 오물은 난분해성 모발로서 이것이 하수의 악취를 막기 위한 유트랩 장치에 다량으로 쌓이게 된다. 이러한 오물은 물의 흐름을 막는 현상을 일으키기 때문에 대부분의 가정에서 이를 해결하기 위해 상업적으로 제조된 화학적 분해 용액을 하수구에 과량 투입하여 하수구의 막힘 현상을 해결하고 있다. 본 연구에서는 난분해성 케로틴 단백질이 주성분인 모발을 절단 분쇄하는 장치를 개발하여 실험하였다. 실험을 위하여 모발을 효과적으로 절단할 수 있는 절단 분쇄장치를 설계하였으며 그 절단 성능을 실험적인 방법을 통해 규명하였다. 모발 절단 분쇄 장치의 성능을 평가하기 위하여 섬유다발을 부분 절단한 후 무게를 측정하는 방법을 사용하여 절단 모발의 평균길이를 구하였다. 이 방법은 비교적 간단한 무게 측정 방법을 통해 섬유상의 평균 길이를 구하는 것인데, 이를 모발에 적용하여 평균 모발 길이를 크지 않은 오차 범위에서 구할 수 있었다. 또한, 평균절단수를 정의하여 본 연구를 위해 고안된 모발 절단 분쇄 장치의 성능을 평가하였다. 평균절단수 분석 방법을 적용하여 주어진 실험 조건에서 최적의 구조와 최적의 작동시간을 구하는 기준을 제시할 수 있었다. 이러한 실험 방법과 결과는 섬유형태 물질의 절단 분쇄가 필요한 다른 장치에서도 설계와 분석에 사용할 수 있는 하나의 좋은 예시가 될 것이다. 본 연구에서 고안된 절단 분쇄 장치가 실험을 통하여 효과적으로 모발을 절단 분쇄하는 것을 확인할 수 있었다. 이러한 장치를 일반 가정에 설치하여 보급함으로써 최근 심각해지고 있는 하수구에 의한 수질환경 오염 방지에도 효과적인 도움이 될 것이다.