• 제목/요약/키워드: Experimental bias

검색결과 434건 처리시간 0.038초

Mathematical and experimental study of hydrogen sulfide concentrations in the Kahrizak landfill, Tehran, Iran

  • Asadollahfardi, Gholamreza;Mazinani, Safora;Asadi, Mohsen;Mirmohammadi, Mohsen
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.572-581
    • /
    • 2019
  • The emission of hydrogen sulfide (H2S) from the Kahrizak landfill was studied. Firstly, the field measurements were conducted in the summer and winter seasons; and the samples were analyzed using Jacob method. We predicted the H2S concentrations in the downwind using AERMOD and ISCST3. According to the AERMOD, the maximum concentration of H2S in the summer and winter were 117 ㎍/㎥ and 205 ㎍/㎥ respectively. The downwind concentrations reached zero at the distance of 35 km from the leachate treatment plant. The Geometric mean bias, Geometric variance, Fractional bias, Fraction of predictions within a factor of two of the observations and Normalized mean square error for the AERMOD were 0.58, 1.35, -0.12, 1.91 and 0.042, respectively in the summer and 1.39, 1.35, -0.05, 1.46 and 0.027 in the winter; and for the ISCST3, were 0.85, 1.03, 0.02, 1.45 and 0.04 in the summer and 1.18, 1.03, 0.15, 1.16 and 0.04 in the winter. The results of the AERMOD were compared with the ISCST3 and indicated that the AERMOD performance was more suitable than the ISCST3.

유량제어용 서보밸브와 비례방향밸브의 압력신호를 이용한 정적 성능 진단에 관한 연구 (Static Performance Diagnosis Based on Pressure Signal for a Flow Control Servovalve or Proportional Direction Valve)

  • 김성동;전세형;김인동;함영복
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.32-41
    • /
    • 2012
  • Most diagnosis methods for servo valves requires installing spool displacement sensor or flow sensor as well as pressure sensor. The measurement of flow is hard to implement and many kinds of servovalves or proportional direction valves do not have a built-in spool displacement sensor. In this study, static performances of servovalve or proportional-direction-valve are studied theoretically and a diagnosis technique, which uses only load pressure and input current signal, is assessed. An experimental setup was made based upon a personal computer and the LabVIEW graphical language. A series of diagnosis tests were performed and the analysis results showed it possible to measure the pressure gain, hysteresis and null bias in a relatively simple methodology.

콜피츠 전압제어 발진기 동작의 새로운 해석 및 구현에 관한 연구 (A Study on the New Analysis to the Dynamics of Colpitts VCO's and Practical Implication)

  • 김학선;황인갑;이형재
    • 한국통신학회논문지
    • /
    • 제19권12호
    • /
    • pp.2439-2447
    • /
    • 1994
  • Colpitts VOC(Voltage Controlled Oscillator)의 새로운 모델링을 제시하였다. 일반적으로 VOC의 해석에는 2차원 모델이 사용되고 있는데 본 논문에서는 3차원 모델을 사용하였다. 이는 수학적으로 정확함은 물론 실제적으로도 유용하게 사용할 수 있다. 이러한 잇점은 실제의 VOC는 콜피츠 발진회로에 기초한 것이며 이는 3차원 시스템이기 때문이다. 모델링은 선형 근사법으로 시작하여 HBM(harmonic balance method)에 의하여 비선형 해석으로 접근하였다. 이 해석에서는 시스템의 출력에 영향을 주는 발진과 함께, 겹쳐서 나타나는 시프팅 바이어스라는 새로운 모드의 존재를 드러내었다. 더우기 해석의 성과는 발진 주파수의 변화를 시도하고자 할 때 발진기의 피라미터를 변화시키는 유용한 과정을 추출하였다. 시뮬레이션으로 이를 확인하고 개인용 휴대전화기에 사용될 GaAs MESFET VCO 실제회로에 적용시켜 본 결과 매우 잘 일치하였다.

  • PDF

The Dry Etching Properties on TiN Thin Film Using an N2/BCl3/Ar Inductively Coupled Plasma

  • Woo, Jong-Chang;Joo, Young-Hee;Park, Jung-Soo;Kim, Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권4호
    • /
    • pp.144-147
    • /
    • 2011
  • In this work, we present a study regarding the etching characteristics on titanium nitride (TiN) thin films using an inductively coupled plasma system. The TiN thin film was etched using a $N_2/BCl_3$/Ar plasma. The studied etching parameters were the gas mixing ratio, the radio frequency (RF) power, the direct current (DC)-bias voltages, and the process pressures. The baseline conditions were as follows: RF power = 500 W, DC-bias voltage = -150 V, substrate temperature = $40^{\circ}C$, and process pressure = 15 mTorr. The maximum etch rate and the selectivity of the TiN to the $SiO_2$ thin film were 62.38 nm/min and 5.7, respectively. The X-ray photoelectron spectroscopy results showed no accumulation of etching byproducts from the etched surface of the TiN thin film. Based on the experimental results, the etched TiN thin film was obtained by the chemical etching found in the reactive ion etching mechanism.

포켓 이온 주입된 MOSFET소자의 1/f 잡음 특성 (An Analysis of the 1/f Noise Characteristics of Pocket Implanted MOSFETS)

  • 이병헌;이기영
    • 대한전자공학회논문지SD
    • /
    • 제41권3호
    • /
    • pp.1-8
    • /
    • 2004
  • 본 연구에서는 소오스와 드레인 근처에 포켓형상으로 이온이 주입되어 halo구조를 갖고 있는 MOSFET 소자의 1/f 잡음 특성에 대하여 고찰하였다. 채널 방향으로 전도도가 균일하지 않은 MOSFET 소자가 선형영역에서 동작할 때, 영역구분 근사기법(regional approach)을 근간으로 논의된 기존의 1/f 잡음모델을 영역별로 서로 다른 전기적 성질이 정의될 수 있는 halo MOSFET 소자에 적용하여 그 타당성을 조사하였다. 잡음모델의 검증을 위하여 기존의 모델에서와 같이 영역구분 근사를 사용하여 보다 넓은 동작범위에서 적용될 수 있도록 기존의 모델식을 개선하였다. 개선된 잡음식은 선형영역에서 기존에 보고된 잡음식에 수렴한다. 실험적으로 측정된 1/f 잡음 특성과의 비교에서 영역구분 근사기법으로 정리된 잡음식은 게이트 전압이 비교적 큰 경우에 한해서 적용될 수 있음을 보였다.

Effects of hippotherapy on children with cerebral palsy: systematic review and meta-analysis

  • Kim, Kwon-Hoi;Lee, Suk-Min
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권1호
    • /
    • pp.55-65
    • /
    • 2020
  • Objective: The most important goal of hippotherapy is to improve function, gait, and balance. The purpose of this study was to investigate the effects of hippotherapy on function, gait, and balance of children with cerebral palsy (CP). Design: A systematic review and meta-analysis. Methods: We've searched the PubMed, EMBASE, and Cochrane Library CENTRAL databases for English experimental studies published up until September 2018. To analyze the effects of hippotherapy on the function, gait, and balance of children with cerebral palsy, the systematic review and meta-analysis were performed on Patient/Participants/Population Problem, Intervention, Comparison, Outcome with Timing, Setting Study Design. Papers retrieved from the database were removed from the literature management database. Methodological quality evaluation was evaluated using Cochrane's risk of bias. Data was analyzed using the Revman 5.3 program of the Cochrane library. Results: In this study, we found that the effect size of hippotherapy, denoted as d, was -3.82, and that hippotherapy had the most effect on gait, but no statistical significant difference was observed. We also found no significant difference in function and balance after hippotherapy. It was found from the funnel plot that there was no publication bias as the plot was symmetrically distributed around the dotted line. Conclusions: There are many unclear studies and a lack of randomized controlled trials (RCTs) in this research area. More RCTs on the effects of hippotherapy on children with CP should be conducted in the future.

음절신호의 음소 분리와 시간-주파수 판별 패턴의 설정 (Phoneme Separation and Establishment of Time-Frequency Discriminative Pattern on Korean Syllables)

  • 류광열
    • 한국통신학회논문지
    • /
    • 제16권12호
    • /
    • pp.1324-1335
    • /
    • 1991
  • 본 논문은 음절을 음소로 분리하고 각각의 특징을 추출하여 음소를 판별할 수 있는 패턴을 설정하는 실험에 관한 연구이다. 음소분리는 피치검출, 각 성문피크펄스의 폭, 포락실, 진폭의 바이어스, 발성시간 등의 파라메타를 적용한다. 최초의 피치는 성문펄스의 폭, 에너지, 정규화와 성문피크의 가변바이어스 등의 변화에 따라 모음 포라선의 봉우리 부분에서 검출, 이를 기준으로 전체의 피치구간을 추적한다. 모음은 포만트 패턴의 유동을 감소시키는 방법과 제2포만트만으로 모음의 판별이 가능함을 제시하며, 피치 고저에 무관한 압축파형을 추정한다. 자음은 포락실, 스펙트럼, 압추파형, 분석방법 등을 발음방법과 음소 상호 영향에서 패턴을 추출한다. 실험결과 모음음소 90%, 초성자음80%, 종성자음 60% 판별된다.

  • PDF

Rotor Initial Position Estimation Based on sDFT for Electrically Excited Synchronous Motors

  • Yuan, Qing-Qing;Wu, Xiao-Jie;Dai, Peng
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.564-571
    • /
    • 2014
  • Rotor initial position is an important factor affecting the control performance of electrically excited synchronous motors. This study presents a novel method for estimating rotor initial position based on sliding discrete Fourier transform (sDFT). By injecting an ac excitation into the rotor winding, an induced voltage is generated in stator windings. Through this voltage, the stator flux can be obtained using a pure integral voltage model. Considering the influence from a dc bias and an integral initial value, we adopt the sDFT to extract the fundamental flux component. A quadrant identification model is designed to realize the accurate estimation of the rotor initial position. The sDFT and high-pass filter, DFT, are compared in detail, and the contrast between dc excitation and ac injection is determined. Simulation and experimental results verify that this type of novel method can eliminate the influence of dc bias and other adverse factors, as well as provide a basis for the control of motor drives.

레이저 빔을 이용한 비정질실리콘 전기적 특성의 비파괴 측정 (Nondestructive Measurement on Electrical Characteristics of Amorphous Silicon by Using the Laser Beam)

  • 박남천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.36-39
    • /
    • 2000
  • A small electrical potential difference which appears on any solid body when subjected to illumination by a modulated light beam generated by laser is called photocharge voltage(PCV)[1,2]. This voltage is proportional to the induced change in the surface electrical charge and is capacitatively measured on various materials such as conductors, semiconductors, ceramics, dielectrics and biological objects. The amplitude of the detected signal depends on the type of material under investigation, and on the surface properties of the sample. In photocharge voltage spectroscopy measurements[3], the sample is illuminated by both a steady state monochromatic bias light and the pulsed laser. The monochromatic light is used to created a variation in the steady state population of trap levels in the surface and space charge region of semiconductor samples which does result in a change in the measured voltage. Using this technique the spatial variation of PCV can be utilized to evaluate the surface conditions of the sample and the variation of the PCV due to the monochromatic bias light are utilized to characterize the surface states. A qualitative analysis of the proposed measurement is present along with experimental results performed on amorphous silicon samples. The deposition temperature was varied in order to obtain samples with different structural, optical and electronic properties and measurements are related to the defect density in amorphous thin film.

  • PDF

한포진 치료의 중의학 임상연구 동향 - 무작위 대조군 임상연구를 중심으로 - (An Overview of Clinical Studies for Pompholyx in Traditional Chinese Medicine - Literature Review based on Randomized Controlled Trials -)

  • 우정아;박범찬;최일신;김기봉;천진홍
    • 대한한방소아과학회지
    • /
    • 제35권4호
    • /
    • pp.82-95
    • /
    • 2021
  • Objectives The purpose of this study is to analyze clinical studies on the effectiveness of TCM (traditional Chinese medicine) for pompholyx treatment and provide evidence for Korean medicine use. Methods Randomized controlled trials (RCT) which used TCM as a treatment for pompholyx were searched in China National Infrastructure (CNKI) platform. The risk of bias of studies was assessed by using Cochrane risk of bias (RoB) 2.0 tool. Results The selected 10 RCTs showed that the experimental group treated with either TCM alone or with a combination of TCM and Western medicine showed more significant therapeutic effect compared to the control group which Western medicine alone. Conclusions Based on the studies from China, TCM may be an effective treatment for pompholyx. This provides evidence for Korean medicine use, and its possible effectiveness in treating pompholyx