• Title/Summary/Keyword: Experimental Size

Search Result 6,501, Processing Time 0.437 seconds

Power Analysis in Experimental Designs with t test Analysis (t 검정 실험 설계 시 표본 크기 결정에 대한 논의)

  • Kang, Jeong-Hee;Bang, Kyung-Sook;Ko, Sung-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.15 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Purpose: In the literature power analysis in experimental studies is often executed and reported falsely. This descriptive study was done to promote the correct application of the Cohen(1988)'s power analysis method. Method: Articles of experimental studies from a nursing journal were selected and reviewed to examine the uses of and the reports on the power analysis process. Also, the appropriate power analysis process was discussed with an example of the most common experimental design, an independent two-group design with t test analysis plan. Result: Around half the experimental studies examined reported that they carried out power analysis. Cohen's method was the most frequently utilized but with accuracy in question. Conclusion: Power analysis to estimate sample size is the interplay between alpha, power, and effect size, and other factors in the case of t test analysis. Researchers should have a clear understanding of how to apply the Cohen's power analysis method so they do not produce poorly estimated sample sizes.

The Effect of a Decrease Indwelling Catheter Size and Preoperative Education on Bladder Discomfort and Patient's Nursing Needs (유치도뇨관 크기 감소 및 정보제공이 수술 후 유치도뇨관으로 인한 불편감과 간호요구도에 미치는 효과: 회복실에 입실한 성인남자 환자를 중심으로)

  • Baek, Hyun Ju;Lee, Hye Mi
    • Journal of Home Health Care Nursing
    • /
    • v.21 no.2
    • /
    • pp.120-126
    • /
    • 2014
  • Purpose: This study was carried out to investigate the effect of a decrease in indwelling catheter size and preoperative education on bladder discomfort and nursing needs. The study was conducted on patients in the recovery room after their surgery. Methods: This study is a randomized control trial. Data were collected from September 2011 to February 2012 at a university hospital in Bundang, Korea. The sample consisted of 75 patients, excluding one patient from the experimental group 2. From among the patients that were sent to the ICU, 24 were in experimental group 1, 24 were in experimental group 2, and 27 were in the control group. Data were collected and analyzed using a chi-square test, t-test, and one-way ANOVA. Results: There were significant differences between the bladder discomfort experienced by patients in experimental group 1 and the control group, and experimental group 2 and the control group. Then nursing needs of the control group were higher than those of the experimental groups 1 and 2. Conclusion: The decrease in indwelling catheter size and preoperative nursing education is an effective nursing intervention in perioperative care.

Evaluation of Allowable Bending Stress of Dimension Lumber; Confidence Levels and Size-adjustment

  • Pang, Sung-Jun;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.432-439
    • /
    • 2013
  • The aim of this study was to investigate the processes for evaluating the allowable bending stress. The confidence levels and the size-adjustment in standards were reviewed with experimental data. The results show that, (1) KS F 2152 was more strict than others overseas standards due to the higher confidence level. The 5% NTL of bending strengths by a method in KS F 2152 were lower than the overseas standards and more specimens were required for evaluating the structural properties according to KS F 2152. (2) Due to the absence of size-adjustment method in domestic standards, the specified size and the exponential parameters on the size-adjustment equation were reviewed by size factors. The specified size (width: 286 mm, length: 6096 mm), and the exponential parameters (w: 0.29, l: 0.14) will be suitable for developing the allowable bending stress in domestic standard. (3) The size adjusted allowable bending stresses of No. 2 grade Korean pine were lower than the allowable stresses tabulated in KBC even though less strict method (75% confidence level) to calculate 5% value was used. The allowable stresses tabulated in KBC are needed to be reviewed by continuous experimental data.

An Experimental Study on the Dowel Action in Reinforcement Concrete Members (철근콘크리트 부재의 장부작용에 관한 실험적 연구)

  • 박송철;신장호;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.250-255
    • /
    • 1993
  • This research is aimed at the experimental investigation of the characteristic contribution of the structural parameters, such as concrete over, concrete strength and reinforcing bar size on the dowel strength of the reinforced concrete stuctures. A total of twenty four specimens were tested for eight experimental conditions. The test results showed relatively close agreements with the values calculated by Vintzeleou-tassios equation. From the observations of the test results, it was found that the concrete cover affected almost linearly on the dowel strength , while the var size and the concrete strength showed coupled effects.

  • PDF

Coal particle distribution inside fuel droplets of high loading CWM (고부하도 CWM 연료방울안에 존재하는 미분탄 분포)

  • 김성준;유영길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.618-629
    • /
    • 1991
  • The purpose of this experiment is to understand the distribution of coal particles inside CWM droplet which is believed to be a very important factor controlling the flame stability. CWM slurry is atomized by an air assisted twin fluid nozzle. An experimental rig is designed and fabricated. The mean size of coal particle distribution in CWM slurry, atomizing air pressure, coal particle loading in slurry and sampling position inside spray are main experimental variables. The atomized CWM droplets are sampled on the thin white layer of magnesium oxide by the emergency sampling shutter. The sampled coal particles on magnesium oxide layers are collected into test tubes and dispersed completely by Ultra-Sonicator. The size distribution of coal particles inside droplets are measured by Coulter Counter. The presence of coal particle inside the impressions of droplets on magnesium oxide layer are investigated by photo technique. There are quite many droplets which do not have any coal particles. Those are just water droplets, not CWM droplets. The population ratio of droplets without coal particles to toal number of droplets is strongly affected by the mean size of coal particle distribution in slurry and this ration becomes bigger number as the mean size of coal particles be larger. The size distribution of coal particles inside CWM droplets is not even and depends on the size of droplet. Experimental results show that the larger CWM droplets has droplets has bigger mean value of particle size distribution. This trend becomes more evident as the atomizing air pressure is raised and the mean size of coal particles in CWM slurry is bigger. That is, the distribution of coal particles inside CWM dropolets is very much affected by the atomizing air pressure and the mean size of pulverized coal particles in CWM slurry.

A Study on Developing Patient Clothing of Free-Size (Free-Size 환자복 개발에 관한연구)

  • 홍정민
    • Journal of the Korean Society of Costume
    • /
    • v.47
    • /
    • pp.113-124
    • /
    • 1999
  • Hospitals in Korea are having trouble with economic matters because of the low cost of medical insurance and the consumer's demand for high-quality care. The management of patient clothing is very difficult Especially for the management of size is very difficult because the mix of patients in the wards is very different from the stocked clothing sizes. Because of economic matters the ward dose not prepare enough clothing for every size. The nurses in the wards have trouble managing the clothing. Therefore the nurses want free-size patient clothing for all patients. The problem of managing the patient's clothing were surveyed by nureses in the wards. It was known that the free-size patient clothing was needed. The clothing designed from 150cm, to 180cm by 5cm were made. The different sizes of clothing were pretested. The experimental clothing were selected. The experimental patient clothing are designed for between from 165cm and 170cm in height which refers to Korean average. The fitness and sensory test were made by medical personnel outpatient who will be future client for hospital and by specialist in clothing. Finally The free-size patient clothing was made. It was said that there is no difference between the C-type (170cm) and the D-typer(165cm) clothing by specialists in clothing. The outpatient future client for hospital liked the C-type was selected. The questionnaires of the C-type patient clothing was tested by outpatient patients and by medical personnel. Eighty-four point-eightprecent(84.8%) of evaluators liked free-size clothing 75.8% liked unisex use.

  • PDF

Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen (집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발)

  • Kim, Donhue
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.557-563
    • /
    • 2022
  • In order to measure the allergen penetration of micropore fabrics, it is necessary to develop a convenient and appropriate experimental method for measuring a pore size of micropore fabrics. In this study, a simple and economical experimental apparatus was developed for the analysis of the pore size of micropore fabrics by measuring the weight reduction rate. In addition, the allergen blocking properties was evaluated by measuring the pore sizes of various fabrics. According to this study, the size of the pores of the microporous fabric could be obtained by measuring the weight reduction rates. In addition, higher weight reduction rate was obtained as the suction pressure passing through the particle permeation device decreased and the suction time was increased. It is expected that the developed experimental method and apparatus can be utilized as an experimental standard for quality control methods to verify the effectiveness of micropore fabrics used for house dust mite blocking bedding.

A Study on Developing Free Size Patient Clothing (Free size 환자복 개발을 위한 실험적 연구)

  • Hwang, Hyo Young;Song, Jung A;Song, Jung Hup
    • Quality Improvement in Health Care
    • /
    • v.5 no.1
    • /
    • pp.92-104
    • /
    • 1998
  • Background : Hospitals in Korea are in trouble at ecomomic matters because of low cost of medical insurance, and consumers' demand for high quality. The management of inpatient clothing is very difficult. Especially the management of patient's clothing size is very difficult because the case mix of patients in wards is very different from the stocked clothing size. Because of the economic matters, the ward does not prepare enough size of clothing. The nurses in ward are in trouble with managing the clothing. So the nurses want free size patient clothing for ease management of clothing size. Method : The experimental inpatinets clothing is designed for in 170cm height refer to Korean standard. The fit of 8 subjects from 150 cm to 185 cm wearing experimental were evaluated by clothing specialists, nurses and patients. Result : 75.8% of evaluators like free size clothing. This results show that the fit of subjects from 160cm to 180cm was good in general but subjects with 150cm, 155cm, 185cm height showed poor fit.

  • PDF

A Study on Size Effect for Compressive Strength of Concrete considering Strength Level (강도수준에 따른 콘크리트 압축강도의 크기효과에 관한 연구)

  • 김희성;진치섭;어석홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.239-244
    • /
    • 1999
  • The reduction phenomena of the compressive strength of concrete with respect to the size of specimens have been extensively investigated. However, adequate analysis technique have not been developed until now. Existing researches have shown that the larger member size, the smaller the strength. This indicated the necessity of nonlinear fracture mechanics theory in order to analyze the fracture behaviors of concrete. The are some models that predict the size effect of compressive strength of cylindrical specimens. Theses equations, however, are developed not considering the difference of fracturing mechanism which depends on both geometry of specimen and the strength level of concrete. In this paper, a model to predict compressive strength of cylindrical concrete specimens with respect to diameters, h/d ratios, and the strength level of concrete, is suggested. For this purpose, theoretical and statistical analyses are conducted. Experimental constants used in the model of new size effect are formulated in terms of strength levels of concrete based on existing experimental data.

  • PDF

A numerical analysis and experimental study on the prediction of spray characteristics (분무특성 예측을 위한 이론적 접근과 실험적 연구)

  • Yoon, S.J.;Cho, D.J.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.1-13
    • /
    • 1998
  • A theoretical and experimental study was carried out to predict the drop size distribution of the pressure swirl atomizer. Various analytical methods using the Kelvin-Helmholtz instability theory were tried to examine the wave growth on cylindrical liquid sheets. Cylinderical liquid sheets were extended to the case with the conical sheets. Perturbations due to tangential motion as well as longitudinal one were taken into account. And it was assumed that the breakup occurs when amplitude ratio exceeds exp(12), drop sizes were predicted only by theoretical approach. Drop size distribution was obtained by using maximum entropy formalism. Seven constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of estimating source terms. In this study $D_{10}$ only was introduced into the formulation as a constraint. The predicted drop size and drop size distribution agreed well with the measured data.

  • PDF