• 제목/요약/키워드: Experimental Frame Test

검색결과 422건 처리시간 0.021초

용접 순서의 변화에 따른 자동차용 Frame의 변형과 잔류 응력 분석 (Deformation and Residual Stress Analysis of Automotive Frame Following as Welding Sequency Variation)

  • 박태원;김기주;원시태;한창평
    • 한국자동차공학회논문집
    • /
    • 제21권3호
    • /
    • pp.50-57
    • /
    • 2013
  • The high temperature thermal attacks in welding can affect the residual stress of a frame for automotive assembly accompanying frame deformation. Also the residual stress can induce the negative effect on durability performance of the automobile. In order to analyze the frame deformation, the simplified test frame which had the similar shape (form) of the real automotive frame was fabricated. The contactless optical 3D scanner was used for the shape difference measurement of the frame between before and after the welding. The FE-model of the test frame was composed and the deformation and residual stress simulation were performed. The simulated results were compared with the measured results for the reference of the frame design following as the variation of welding sequency. The deformation shape of the frame by simulation was in good agreement with that by the experimental measurement. In addition, the optimized welding sequency with reduced deformation after welding could be achieved through these analyses.

용접에 의한 자동차용 Frame의 변형과 잔류 응력 분석 (Deformation and Residual Stress of Automotive Frame by Welding)

  • 박태원;김기주;한창평;이영숙;임종한
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.113-117
    • /
    • 2011
  • The frame for automotive assembly can be deformed and remained on the residual stress due to high temperature thermal attacks when in welding. The frame deformation can be made to problems when in assembly with body and the residual stress can affect the negative effect on durability performance of the automobile. In order to analyze the frame deformation, the simplified test frame which had the similar shape (form) of the real automotive frame was fabricated. The contactless optical 3D scanner was used for the shape difference measurement of the frame between before and after the welding. The FE-model of the test frame was composed and the heat transfer and thermal stress simulation were performed. The simulated results were compared with the measured results for the reference of the frame design. The deformation shape of the frame by simulation was in good agreement with that by the experimental measurement.

Experimental research on seismic behavior of a composite RCS frame

  • Men, Jinjie;Zhang, Yarong;Guo, Zhifeng;Shi, Qingxuan
    • Steel and Composite Structures
    • /
    • 제18권4호
    • /
    • pp.971-983
    • /
    • 2015
  • To promote greater acceptance and use of composite RCS systems, a two-bay two-story frame specimen with improved composite RCS joint details was tested in the laboratory under reversed cyclic loading. The test revealed superior seismic performance with stable load versus story drift response and excellent deformation capacity for an inter-story drift ratio up to 1/25. It was found that the failure process of the frame meets the strong-column weak-beam criterion. Furthermore, cracking inter-story drift ratio and ultimate inter-story drift ratio both satisfy the limitation prescribed by the design code. Additionally, inter-story drift ratios at yielding and peak load stage provide reference data for Performance-Based Seismic Design (PBSD) approaches for composite RCS frames. An advantage over conventional reinforced concrete and steel moment frame systems is that the displacement ductility coefficient of the RCS frame system is much larger. To conclude, the test results prove that composite RCS frame systems perform satisfactorily under simulated earthquake action, which further validates the reliability of this innovative system. Based on the test result, some suggestions are presented for the design of composite RCS frame systems.

1:12축소 10층 조적 채움 R.C. 골조의 비선형 거동에 대한 실험과 해석의 상관성 (Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Masonry-Infilled Reinforced Concrete Frame)

  • 이한선;김정우
    • 콘크리트학회논문집
    • /
    • 제12권1호
    • /
    • pp.101-112
    • /
    • 2000
  • In many structures, the masonry infill panels have been used for architectural reasons and their influence on the structure is often ignored by engineers. However, it has been recognized that the presence of masonry infills may debates. Recently, the pushover analysis technique is used for the prediction of the inelastic behaviors of structures in the seismic evaluation of existing buildings. However, the reliability of this analysis method has not been fully checked with the test results, particularly in the case of masonry-infilled frames. The objective of this study is to verify the correlation between the experimental and analytical reponses of a high-rise masonry-infilled reinforced concrete frame using DRAIN-2DX program and the test results performed previously. It is concluded from this comparison that the strength and stiffness of members can be predicted with quite high reliability while the ductility capacity of members can not be described reasonably.

브레이스 마운팅 결합부의 피로 수명에 관한 실험적 연구 (An Experimental Study on Fatigue Life of Brace Mounting Joint)

  • 김동우
    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.104-109
    • /
    • 1998
  • This document is a experimental study on fatigue life of brace mounting weld joint. A brace is used to put sub-frame together on the main frame with high strength bolts. It has low fatigue life so a patch is in need for improving a fatigue characteristics of welded joint in brace mounting This paper presents the most pertinent patch size for truck. For this, a critical stress is computed at the point of fatigue crack occurred on truck frame by finite Element Analysis. Using by this critical stress. Designers are able to determin whether fatigue crack is occurred and are able to select a pertinent patch type. And then, with a selected patch type, structural joint stiffness was estimated to compare to the conventional and other patch type or brace mounting Finally, fatigue test were performed to prove a suitability of selected prototype compare with the conventional and other patch type or brace mounting.

차량용 서브프레임의 동특성 해석 (Dynamic Analysis of Vehicle Sub-frame)

  • 이봉현;김찬중;김기훈
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1332-1339
    • /
    • 2005
  • The vibration of Powertrain are one of the import design characteristics of a vehicle. Powertrain is mostly mounted to the front subframe and powertrain mounting has an important role in determining the vehicle vibration characteristics. In this paper, the accuracy of the vibration analysis for the front subframe is discussed. The dynamic characteristic of subframe are measured from vehicle test and the finite element model updating are performed that natural frequency, mass and MAC of the experimental and theoretical modal analysis are compared. The subframe mounting stiffness are obtained the iteration method based on the vibration of subframe from vehicle test. Finally, the result of dynamic analysis which is operated dynamic load is compared with experimental one of vehicle test.

Cyclic test for solid steel reinforced concrete frames with special-shaped columns

  • Liu, Zu Q.;Xue, Jian Y.;Zhao, Hong T.;Gao, Liang
    • Earthquakes and Structures
    • /
    • 제7권3호
    • /
    • pp.317-331
    • /
    • 2014
  • An experimental study was performed to investigate the seismic performance of solid steel reinforced concrete (SRC) frames with special-shaped columns that are composed of SRC special-shaped columns and reinforced concrete beams. For this purpose, two models of two-bay and three-story frame, including an edge frame and a middle frame, were designed and tested. The failure process and patterns were observed. The mechanical behaviors such as load-displacement hysteretic loops and skeleton curves, load bearing capacity, drift ratio, ductility, energy dissipation and stiffness degradation of test specimens were analyzed. Test results show that the failure mechanism of solid SRC frame with special-shaped columns is the beam-hinged mechanism, satisfying the seismic design principle of "strong column and weak beam". The hysteretic loops are plump, the ductility is good and the capacity of energy dissipation is strong, indicating that the solid SRC frame with special-shaped columns has excellent seismic performance, which is better than that of the lattice SRC frame with special-shaped columns. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. Compared with the edge frame, the middle frame has higher carrying capacity and stronger energy dissipation, but the ductility and speed of stiffness degradation are similar. All these can be helpful to the designation of solid SRC frame with special-shaped columns.

철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame)

  • 신종학;하기주;이희종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.131-139
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of RC frame structures with masonry infilled wall, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame(IFWB-1~3), cumulated energy dissipation capacities were increased by 1.35~1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame.

  • PDF

Wavelet based system identification for a nonlinear experimental model

  • Li, Luyu;Qin, Han;Niu, Yun
    • Smart Structures and Systems
    • /
    • 제20권4호
    • /
    • pp.415-426
    • /
    • 2017
  • Traditional experimental verification for nonlinear system identification often faces the problem of experiment model repeatability. In our research, a steel frame experimental model is developed to imitate the behavior of a single story steel frame under horizontal excitation. Two adjustable rotational dampers are used to simulate the plastic hinge effect of the damaged beam-column joint. This model is suggested as a benchmark model for nonlinear dynamics study. Since the nonlinear form provided by the damper is unknown, a Morlet wavelet based method is introduced to identify the mathematical model of this structure under different damping cases. After the model identification, earthquake excitation tests are carried out to verify the generality of the identified model. The results show the extensive applicability and effectiveness of the identification method.

1:12축소 10층 철근콘크리트 골조-벽식 구조의 비선형 거동에 대한 실험과 해석의 상관성 (Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Reinforced Concrete Frame-Wall Structure)

  • 이한선;김상호
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.119-126
    • /
    • 2000
  • Reinforced concrete structural walls are widely known to provide an efficient lateral load resistance and drift control. However, many reported researches on them are mostly limited to the RC structural walls reinforced according to seismic details. When the pushover analysis technique is used for the prediction of inelastic behavior of frame-wall structures for the seismic evaluation of existing buildings having non-seismic details, the reliability of this analysis method should be checked by the test results. The objective of this study is to verify the correlation between the experimental and analytical responses of a high-rise reinforced concrete frame-wall structure having non-seismic details by using DRAIN-2DX program[11] and the test results performed previously[1]. It is concluded that the behavior of the frame-wall model is mainly affected by the fixed-end rotation(uplift at base) and bending deformation of the wall and that the analysis with the LINKS model[10] in DRAIN-2DX describes them with good reliability.