• Title/Summary/Keyword: Experimental Facility

Search Result 771, Processing Time 0.033 seconds

Effect of Laugher Therapy on Pain, Depression and Sleep with Elderly Patients in Long Term Care Facility (웃음요법이 입원 노인 환자의 통증, 우울 및 수면에 미치는 영향)

  • Lee, Kyeong-Im;Eun, Young
    • Journal of muscle and joint health
    • /
    • v.18 no.1
    • /
    • pp.28-38
    • /
    • 2011
  • Purpose: This paper was aimed to investigate the effect of laugher therapy on the pain, depression and sleep disturbance in elderly patients who admitted in long term care facility. Method: This study used a nonequivalent control group pretest-posttest design. A sample of 40 elderly patients (20: experimental group, 20: control group, 65 or older) were recruited. Visual analogue scale was used to measure level of pain level, Geriatric Depression Scale Short Form Korea Version (GDSSF-K) for depression. Sleep Scale for sleep. The laugher therapy was given twice a week for four weeks (8 times). Each therapy consists of preparatory, action and finishing stage. Data were analyzed by PASW 18.0. Results: The pain score in experimental group was significantly different from that in control group (t=4.17, p<.001). The level of depression in experimental group was significantly different from that in control group (Z=4.12, p<.000). The level of sleep in experimental group was not significantly different from that in control group (Z=-1.43, p<.152). Conclusion: A laugher therapy is expected to be practical used an efficient method of a nursing intervention to elderly patients in long term care facility.

A study on optimal of block facility layout using Hybrid GA (Hybrid GA를 이용한 최적의 블록단위 설비배치에 관한 연구)

  • 이용욱;석상문;이철영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.131-142
    • /
    • 2000
  • Facility layout is the early stage of system design that requires a mid-term or long-term plan. Since improper facility layout might incur substantial logistics cost including material handling and re-installment costs, due consideration must be given to decisions on facility layout. Facility layout is concerned with low to arrange equipment necessary for production in a given space. Its objective is to minimize the sum of all the products of each equipment's amount of flow multiplied by distance. Facility layout also is related to the issue of NP-complete, i.e., calculated amounts exponentially increase with the increase of the number of equipment. This study discusses Hybrid GA developed, as an algorithm for facility layout, to solve the above-mentioned problems. The algorithm, which is designed to efficiently place equipment, automatically produces a horizontal passageway by the block, if a designer provides the width and length of the space to be handled. In addition, this study demonstrates the validity of the Algorithm by comparing with existing algorithms that have been developed. We present a Hybrid GA approach to the facility layout problem that improves on existing work in terms of solution quality and method. Experimental results show that the proposed algorithm is able to produce better solution quality and more practical layouts than the ones obtained by applying existing algorithms.

  • PDF

An Expert System and Genetic Algorithm for Facility Layout Problem

  • Limudomsuk, Thitipong;Sirinaovakul, Boonchareon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1654-1657
    • /
    • 2002
  • This paper presents a system for facility layout problem using an expert system and a genetic algorithm. The practical facility layout design can be effected by characteristics of constructing model, slicing tree model, closeness weight metric and expert system. The genetic algorithm searches the result layout. An experimental system is implemented and produced desired layout.

  • PDF

An Experimental Study of Spray Nozzle Desalination Facility (담수화 설비 스프레이 노즐에 대한 실험적 연구)

  • SHIN HYUN-KYOUNG;JOO HYUN-TAE;PARK MIN-HO;PARK KYOUNG-MIN;KIM JIN-YOUNG;LIM JIN-YOUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.1 s.68
    • /
    • pp.26-31
    • /
    • 2006
  • Experimental research was undertaken to develop a domestic spray nozzle used on equipment for desalination. First, we made a test set-up in order to confirm nozzle efficiency of spray and distribution under different pressure conditions. Then, we found a maximum spray condition after verifying reliability of this facility. An optimum arrangement of the nozzle, based on the test result, was made using CATIA V5 and EXCEL.

An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas (헬륨을 이용한 열유속센서 검정방법의 실험적 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

A Study on the Development of the Experimental Educational Facility Management Information System based on the Nationwide Development Plan of the Educational Administration Information System (전국단위(全國單位) 교육행정정보체계(敎育行政情報體系) 구축사업(構築事業) 적용(適用)을 위한 실험적(實驗的) 교육시설현황관리(敎育施設現況管理)시스템 개발(開發)에 관한 연구(硏究))

  • Ock, Jong-Ho;Ahn, Byong-Hwan
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.2
    • /
    • pp.5-13
    • /
    • 2002
  • The main objective of this research is to develop an experimental educational facility management information system that will be used for maintaining existing educational facilities in the elementary, junior high, and high schools. The development is based on the nationwide development plan of the education administration information system. The system developed is accomplished by use of Map-application Information System(MAPIS), an applied commercial software that combines Geographic Information System(GIS) with existing Information and Communication Technologies(ICT) such as Database system, Multimedia methodology, and Internet system. In order to figure out the features to be improved in the system developed, the research interviewed the educational facilities management in the Ministry of Education and P Local Education Authority. The authors suggest the functional improvement of the system based on the interview results.

Fall arresting system

  • Leamon, T.S.;Malone, C.;Son, D.H.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • A major inhibition of past work in a slip/fall accident study has been due to the lack of a facility and a methodology to experimentally investigate such behavior without expowting human subjects to the natural danger of injury resulting from a fall. In order to carry out a slip/fall research, a unique facility must be created specially to investigate falling and slipping behavior. One component of this facility will be used to focus a research towards experimental investigations of the basic mechanisms involved in falls. Especially, this compo- nent must be designed, developed, and fabricated to provide passive, reactive support at the point of loss of ba- lance. This component must allow both normal and reduced friction surfaces to be designated to investigate human falling in the experimental conditions. This study will address how a fall arresting system was designed and it would be implemented in actual case of a slip/fall study.

  • PDF

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF

Hydrogen Behavior at a Subcomparment in The Containment Building

  • Lee, U.J.;Park, G.C.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.495-500
    • /
    • 1997
  • For hydrogen management in severe accidents with degraded nuclear core of PWR's, several experiments have been performed in the SNU hydrogen mixing facility. The objectives are understanding the extent of hydrogen mixing and analyzing the effects of factors which dominate uniform or non-uniform mixing at compartments in the containment building. The facility represents on a 1/11th linearly scaled model of the YGN unit 3&4, hydrogen was simulated by helium. Because there are the gaps between safety injection tank and compartment layers in the containment, the test facility was constructed in three dimentinal mode for analyzing of mixture behavior through the gaps. From the experimental results we could conclude that overall hydrogen concentration distributed uniformly in the free volume of the test compartment, but fluctuated in the gaps. This paper is focused on experimental result from several experiment.

  • PDF

Complete Characteristic Curve for a Reactor Coolant Pump (원자로 냉각재 펌프의 완전 특성 곡선)

  • Yoo, IlSu;Park, MuRyong;Hwang, SoonChan;Yoon, EuiSoo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.5-10
    • /
    • 2012
  • An experimental test facility for the complete characteristics of pumps is constructed at KIMM(Korea Institute of Machinery and Materials). All sensors instrumented in test facility for measuring flow rate, pressure, force and moment are in-situ calibrated by primary method. This paper describes the test facility and test technique of the complete characteristics of pumps, together with an experimental test results for a reactor coolant pump which is designed at KIMM for the first time in Korea. The test results for the mixed-flow type pump of $n_s$=1.425 are presented by three curves: constant head, torque, and speed.