• Title/Summary/Keyword: Experimental Confirmation

Search Result 126, Processing Time 0.028 seconds

Performance Ability after CPR Education of the ground workers in an airport (공항 지상 근무자의 심폐소생술 수행능력)

  • Shin, Ji-Hoon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.29-40
    • /
    • 2009
  • Objective : This study is an experimental study which is designed to examine the differences between knowledge and self-confidence before and after theory education(CPR PPT material) based on guidelines of CPR and emergency cardiac treatment of American Heart Association(AHA, 2005) and video self-instruction program for the general public by Korean Association of Cardiopulmonary Resuscitation(KACPR), trace CPR performance ability after CPR and AED education and investigate the accuracy of artificial respiration and chest compression, and know the difference in CPR performance abilities including AED. Methods : Subjects of this study include ground crews and staffs at M airport in G province equipped with emergency equipments for CPR according to Art. 47, Sec. 2 of Emergency Medical Law, airport police, rent-a-cops, security guard, quarantine officer, custom officer, and communication, electricity, civil engineering, facility management staff, airport fire fighting staff, air mechanic, traffic controller, and airport management team among airport facility management staffs. They were given explanation of necessity of research and 147 of 220 subjects who gave consent to this research but 73 who were absent from survey were excluded were used as subjects of this study. of 147 subjects, there were 102 men and 45 women. Results : 1) Knowledge score of CPR was $6.18{\pm}0.87$ before instruction and it was increased to $15.12{\pm}1.78$ after instruction, and there was statistically significant difference. 2) Self-confidence score in CPR was $3.16{\pm}0.96$ before instruction and it was increased to $7.05{\pm}0.75$ after instruction, and there was statistically significant difference. 3) Total average score in CPR performance ability after instruction was 7.46 out of 9, performance ability was highest in confirmation of response as 144(97.95%), follwed by request of help as 140(95.25%) and confirmation of respiration as 135(91.83%), and lowest in performing artificial respiration twice(gross elevation of chest) as 97(65.98%). Accuracy of artificial respiration(%) was $28.60{\pm}16.88$ and that of chest compression(%) was $73.10{\pm}22.16$. 4) Performance ability of AED after instruction showed proper performance in power on by 141(95.91%) and attaching pad by 135(91.83%), hand-off for analyzing rhythm showed 'accuracy' in 115(78.23%) and 'non-performance' in 32(21.77%), delivery of shock and hand-off confirmation showed 'accuracy' in 109(74.14%) and 'inaccuracy' in 38(25.86%), and beginning chest compression immediately after AED was done by 105(71.42%).

  • PDF

An Experimental Study on the Level Control of the Steam Generator in Nuclear Power Plant (원자력발전소 증기발생기 수위제어에 대한 실험적 연구)

  • 문제선;양명승;김기현;유재석;박영무
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.170-175
    • /
    • 1997
  • An experimental study was carried out with the Mock-up made for the improved water level control of the steam generator in nuclear power plant and for the confirmation of swell/shrink status of the water level by opening and closing the steam dump valve. We can confirmed the possibility of using the Mock-up by introducing the PI controller and the FUZZY controller. Accordingly, we can confirmed that the practical usability of advanced controllers, which will be developed for the improved water level control of the steam generator in nuclear power plant by using the Mock-up.

  • PDF

Influence of uplift on liquid storage tanks during earthquakes

  • Ormeno, Miguel;Larkin, Tam;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • v.1 no.4
    • /
    • pp.311-324
    • /
    • 2012
  • Previous investigations have demonstrated that strong earthquakes can cause severe damage or collapse to storage tanks. Theoretical studies by other researchers have shown that allowing the tank to uplift generally reduces the base shear and the base moment. This paper provides the necessary experimental confirmation of some of the numerical finding by other researchers. This paper reports on a series of experiments of a model tank containing water using a shake table. A comparison of the seismic behaviour of a fixed base system (tank with anchorage) and a system free to uplift (tank without anchorage) is considered. The six ground motions are scaled to the design spectrum provided by New Zealand Standard 1170.5 (2004) and a range of aspect ratios (height/radius) is considered. Measurements were made of the impulsive acceleration, the horizontal displacement of the top of the tank and uplift of the base plate. A preliminary comparison between the experimental results and the recommendations provided by the liquid storage tank design recommendations of the New Zealand Society for Earthquake Engineering is included. The measurement of anchorage forces required to avoid uplift under varying conditions will be discussed.

Optimization of L-shaped Corner Dowel Joint in Modified Poplar using Finite Element Analysis with Taguchi Method

  • Ke, Qing;Zhang, Fan;Zhang, Yachi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.204-217
    • /
    • 2016
  • Modified poplar has emerged as a potential raw material for furniture production. Lack of specific modified poplar strength information; however, restricts applications in the furniture industry especially as related to strength in corner-joints. Optimization of strength in L-shaped corner dowel modified poplar joints under compression loads utilizing finite element analysis (FEA) by Taguchi method with the focus of this study. Four experiment factors (i.e., Structure Style, Tenon Length, Tenon Diameter, and Tenon Gap), each at three levels, were conducted by adopting a $L_9-3^4$ Taguchi orthodoxy array (OA) to determine the optimal combination of factors and levels for the von Mises stress utilizing ANSYS software. Results of Signal-to-Noise ratio (S/N) analysis and the analysis of variance (ANOVA) revealed the optimal L-shaped corner dowel joint in modified poplar is $45^{\circ}$ Bevel Butt in structure style, 24 mm in tenon length, 6 mm in tenon diameter, and 20 mm in tenon gap. Tenon length and tenon gap are determined to be significant design factors for affecting von Mises Stress. Confirmation tests with optimal levels and experimental test indicated the predicted optimal condition is comparable to the actual experimental optimal condition.

A Composition and Basis Experiment of Single Cylinder Low Speed Diesel Engine for Atkinson Cycle Materialization (앳킨슨사이클 실현을 위한 단기통 저속 디젤기관의 구성과 기초 실험)

  • Jang, Jtaeik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.5
    • /
    • pp.461-466
    • /
    • 2013
  • In this research, the diesel cycle was thermodynamically interpreted to evaluate the possibility of high efficiency by converting diesel engine to the atkinson cycle, and general cycle features were analyzed after comparing these two cycles. That an experimental single cylinder and a long stroke diesel-atkinson engine, of which S/B ratio was more than 3, were manufactured. After evaluating the engine through basic experiments, a diesel engine was converted into the atkinson cycle by constituent VCR (variable compression ratio) device and VVT (variable valve timing) system. The experimental method was to observe compression work reduction effects due to low compression effects from delayed intake valve closing of the early stage atkinson engine. The result, the possibility of increasing compression ratio about each engine load was confirmation by constructing compensate expansion-compression ratio in accordance with the delayed intake valve close.

Air-Water Two-Phase Flow Test Facility of a Single Stage Closed-type Centrifugal Pump (단단 밀폐형 원심펌프의 기액이상류 성능시험 설비)

  • Kim, S. Y.;Lee, S. L.;Kim, Y. T.;Kim, S. D.;Lee, Y. S.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.49-53
    • /
    • 2004
  • LabVIEW is mostly preferred to use in experiment, measurement and control as one of the useful thing in America and Europe. So, We tried performance experiment of a single-stage closed-type centrifugal pump by using the LabVIEW. The pump rpm and the shaft torque are measured by rpm sensor and torque sensor The test pump's maximum rpm, head, kW are 1,750, 13m, and 1.5kW, respectively The casing is made up with transparency acrylic for confirmation the flow patterns. We installed experimental equipment for air water two phase flow. This paper tries to analyze the single-phase flow characteristics through this air water two phase flow experimental apparatus. The performance results of a single-stage closed-type centrifugal pump satisfied reappearance and coincide well with head and coefficients according to the change of rpm.

  • PDF

Statistical Analysis of Cutting Force for End Milling with Different Cutting Tool Materials (공구재종에 따른 엔드밀 가공의 절삭력에 관한 통계적해석)

  • Choi, Man Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.86-91
    • /
    • 2016
  • End milling is an important and common machining operation because of its versatility and capability to produce various profiles and curved surfaces. This paper presents an experimental study of the cutting force variations in the end milling of SM25C with HSS(high speed steel) and carbide tool. This paper involves a study of the Taguchi design application to optimize cutting force in a end milling operation. The Taguchi design is an efficient and effective experimental method in which a response variable can be optimized, given various control and noise factors, using fewer resources than a factorial design. This study included feed rate, spindle speed and depth of cut as control factors, and the noise factors were different cutting tool in the same specification. An orthogonal array of $L_9(3^3)$ of ANOVA analyses were carried out to identify the significant factors affecting cutting force, and the optimal cutting combination was determined by seeking the best cutting force and signal-to-noise ratio. Finally, confirmation tests verified that the Taguchi design was successful in optimizing end milling parameters for cutting force.

Effect of Process Parameters on Microhardness of Ni-Al2O3 Composite Coatings (Ni-Al2O3 복합코팅의 마이크로 경도에 대한 공정변수의 영향)

  • Jin, Yeung-Jun;Park, Simon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1037-1045
    • /
    • 2022
  • In this study, nanoscale Al2O3 ceramic particles were used due its exceptionally high hardness characteristics, chemical stability, and wear resistance properties. These nanoparticles will be used to investigate the optimal process conditions for the electro co-deposition of the Ni-Al2O3 composite coatings. A Watts bath electrolytic solution of a controlled composition along with a fixed agitation speed was used for this study. Whereas the current density, the pH value, temperature and concentration of the nano Al2O3 particles of the electrolyte were designated as the manipulative variables. The experimental design method was based on the orthogonal array to find the optimum processing parameters for the electro co-deposition of Ni-Al2O3 composite coatings. The result of confirmation experimental based on the optimal processing condition through the analysis of variance ; EDX analysis found that the ratio of alumina increased to 8.65 wt.% and subsequently the overall hardness increased to 983 Hv. Specially, alumina were evenly distributed on Nickel matrix and particles were embedded more firmly and finely in Nickel matrix.

Laser micro-drilling of CNT reinforced polymer nanocomposite: A parametric study using RSM and APSO

  • Lipsamayee Mishra;Trupti Ranjan Mahapatra;Debadutta Mishra;Akshaya Kumar Rout
    • Advances in materials Research
    • /
    • v.13 no.1
    • /
    • pp.1-18
    • /
    • 2024
  • The present experimental investigation focuses on finding optimal parametric data-set of laser micro-drilling operation with minimum taper and Heat-affected zone during laser micro-drilling of Carbon Nanotube/Epoxy-based composite materials. Experiments have been conducted as per Box-Behnken design (BBD) techniques considering cutting speed, lamp current, pulse frequency and air pressure as input process parameters. Then, the relationship between control parameters and output responses is developed using second-order nonlinear regression models. The analysis of variance test has also been performed to check the adequacy of the developed mathematical model. Using the Response Surface Methodology (RSM) and an Accelerated particle swarm optimization (APSO) technique, optimum process parameters are evaluated and compared. Moreover, confirmation tests are conducted with the optimal parameter settings obtained from RSM and APSO and improvement in performance parameter is noticed in each case. The optimal process parameter setting obtained from predictive RSM based APSO techniques are speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), Air pressure (1 kg/cm2) for Taper and speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), air pressure (3 kg/cm2) for HAZ. From the confirmatory experimental result, it is observed that the APSO metaheuristic algorithm performs efficiently for optimizing the responses during laser micro-drilling process of nanocomposites both in individual and multi-objective optimization.

Reemergence of mumps

  • Choi, Kyong-Min
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.5
    • /
    • pp.623-628
    • /
    • 2010
  • The mumps virus is a single-stranded, non-segmented, negative-sense RNA virus belonging to the $Paramyxoviridae$ family. Mumps is characterized by bilateral or unilateral swelling of the parotid gland. Aseptic meningitis is a common complication, and orchitis is also common in adolescents and adult men. Diagnosis is based on clinical findings, but because of high vaccination coverage, clinical findings alone are not sufficient for diagnosis, and laboratory confirmation is needed. Mumps is preventable by vaccination, but despite high vaccination coverage, epidemics occur in several countries, including Korea. Many hypotheses are suggested for these phenomena. In this review, we investigate the reason for the epidemics, optimal methods of diagnosis, and surveillance of immunization status for the prevention of future epidemics.