• Title/Summary/Keyword: Expansion cooling

Search Result 297, Processing Time 0.021 seconds

Comparison analysis of cooling loads according to window systems and balcony expansion for a high-rise residential building (초고층 공동주택에서 발코니 확장에 따른 창호시스템별 냉방부하 분석 및 비교)

  • Kim, Yun-Jin;Park, Sang-Hyun;Lee, Jong-Chan;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.184-189
    • /
    • 2008
  • These days, Apartment is altered oversized and high-rise through construction techniques development. Also, the cost of cooling and heating load would be expected by balcony expansion into inner space caused by legalization. In specially, HVAC systems of high-rise residential building almost apply to pre-existence techniques of middle and low residential building except for consideration and methods of the air inflow minimization into indoor through mechanical ventilation is used in ventilation system. From these cause, window systems of high-rise apartments stands high in estimation of components. Thus, purpose of this study is to make a comparative study through difference of window systems.

  • PDF

Ice slurry transporting and branching characteristics for the district cooling (지역냉방을 위한 아이스슬러리 시스템의 수송 및 분기 특성)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo;Lee, Chang-Jun;Kwon, Hyeok-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.662-667
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$), and the pumping power and branching characteristics are measured by transporting of the ice slurry. The ice slurry transporting pipe is as long as 200 m. For the same cooling load, the higher IPF is, the lower the transporting flow rate and the pumping power are. But when the IPF is higher than 15%, no less decrease of the pumping power does happen. For the branching characteristics, through the branch pipe where the flow resistance is higher, the higher IPF is measured. A little higher IPF is measured at the thermal expansion branch.

  • PDF

Developed Inherent Strain Method Considering Phase Transformation of Mild Steel in Line Heating (선상가열시 강의 상변태를 고려한 개선된 고유변형도 기반의 등가하중법)

  • Ha, Yun-Sok;Jang, Chang-Doo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.6
    • /
    • pp.65-74
    • /
    • 2004
  • The inherent strain method is known to be very efficient in predicting the deformation of steel plate by line heating. However, in the actual line heating process in shipyard, the rapid quenching changes the phase of steel. In this study, In order to consider additional effects under phase transformation, inherent strain regions were assumed to expand. Also, when calculating inherent strain, material properties of steel in heating and cooling are applied differently considering phase transformation. In this process, a new method which can reflect thermal volume expansion of martensite is suggested.8y the suggested method, it was possible to predict the plate deformations by line heating more precisely.

Effects of Refrigerant Charge Amount on the Cooling Performance of a Transcritical $CO_{2}$ Cycle (냉매충전량이 초임계 이산화탄소 사이클의 냉방성능에 미치는 영향에 대한 연구)

  • Cho Honghyun;Ryu Changgi;Kim Yongchan;Sim Yunhee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.410-417
    • /
    • 2005
  • The cooling performance of a transcritical $CO_{2}$ cycle varies significantly with a variation of refrigerant charge amount. In this study, the performance of the $CO_{2}$ system was measured and analyzed by varying refrigerant charge amount at a standard test condition. Besides, the losses of the major components in the $CO_{2}$ system were estimated by evaluating entropy generation with refrigerant charge amount. The losses in the expansion device and the gascooler show the major portion of the total loss. For undercharging conditions, the expansion loss dominates the overall system performance, while the gascooler loss increases significantly with an increase of refrigerant charge amount.

Effects of Design Parameters on Performance of the Stirling Refrigerator

  • Hong, Yon-Ju;Park, Seong-Je;Kim, Hyo-Bong;Park, Young-Don
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.35-39
    • /
    • 2004
  • The split-type free displacer Stirling refrigerators have been widely used for the cooling of infrared sensors and HTS filters. The thermodynamic and electric performance of the Stirling refrigerator is depending on the design and operating parameters. In the Stirling refrigerator with a free displacer, the refrigeration power is a function of the pressure wave in the expansion space, dynamics of a displacer, driving frequency, and etc.. In this study, the analysis of the small Stirling refrigerator was performed to investigate the effects of design parameters on the cooling capacity. The results show the effects of charging pressure, driving frequency, cold end temperature, natural frequency of a displacer and volume of expansion space on the performance of the Stirling refrigerator.

The Modeling of Temperature Changes of Acetylene Clusters formed in Free Jet Expansion (자유팽창으로 생성된 아세틸렌 Cluster의 온도변화에 관한 모델링)

  • Lee Kyung Hee;Kim Hong Rak;Kim Cheol Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.41-46
    • /
    • 2003
  • The Phase and temperature changes of large clusters formed in a free jet expansion of acetylene in 14atm and 233K has been studied. The cluster has been treated as a sphere composed of many shells. A mean diameter of 4.88 microns was obtained by modeling the experimental cooling curve of clusters based on evaporation and heat conduction theory.

  • PDF

Observation of Rotational Cooling of CN($B^2{\Sigma}^+$) Radical Generated in a Supersonic Expansion

  • Lee, Sang-Kuk;Choi, Iek-Soon;Kim, Un-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.5
    • /
    • pp.353-356
    • /
    • 1994
  • The $CN(B^2{\Sigma}^+)$ radical was produced in a jet using an electric dc discharge of the precursor $CH_3CN$ with inert carrier gases. The rotationally resolved Fourier transform emission spectra of the 0-0 band of the $(B^2{\Sigma}^+{\to}X^2{\Sigma}^+)$ transition of CN have exhibited different distribution of the intensity for the carrier gases He and Ar, respectively. From the analysis of intensity distribution in the spectra, the mechanism for rotational cooling process of CN radical in a supersonic expansion has been suggested.

Simple modeling to explore temperatures, heated temperature, and Kappa values of a current sheet observation

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Shen, Chengcai;Kahler, Stephen;Moon, Yong-Jae;Kim, Yeon-Han
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.79.2-79.2
    • /
    • 2021
  • We explore the range of possibilities of temperatures, heated temperature, and Kappa values of a current sheet observation on 2017 September 10. First, we construct a grid model with rapid heating (Theat) and various Kappa (κ) values. We assume a simple density model and use adiabatic cooling to set the temperature during expansion. Next, we calculate the ion fractions using a time-dependent ionization model with adiabatic cooling and various Kappa values. The calculated ion fractions are used to simulate the DNs of the Atmospheric Imaging Assembly on board the Solar Dynamic Observatory. Then, we explore the possible range of the temperatures and Kappa values, comparing the simulated images with the observations. Finally, we discuss the range of the heated temperature and Kappa values and whether the result of this study suggests continuous heating of the current sheet plasma during the expansion.

  • PDF

On Study of Summertime Ice Formation in the Ice Valley at Unchiri, Gangwon-Province (강원도 정선군 운치리 얼음골의 여름철 결빙현상에 관한 연구)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.857-863
    • /
    • 2002
  • The meteorological elements were measured to investigate cause of summertime ice formation at Unchiri, Gangwon Province. The cause of freezing at valley was conformed as adiabatic expansion theory, latent heat of evaporation, natural convective theory, cold air remain theory, and convective freezing theory according to former study. However nither theory produced a satisfactory explanation. This studying area is not valley but ridge, and underground water surface exists at below than freezing height. wintertime temperature drop and summertime cold air spouting were explain as natural convective theory, generation of water drop on the rock was explained as cooling theory by air expansion, and ice formation on the rock was explained as adiabatic expansion theory. In conclusion, formation of ice valley at Unchiri was formed by natural convective theory, adiabatic expansion theory, and latent heat of evaporation successively.

Low Thermal Expansion of $Al_2TiO_5$ Ceramics Prepared from Electrofused Powders

  • Kim, Ik-Jin;Kwak, Hyo-Sup
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.414-418
    • /
    • 1999
  • The synthesis of polycrystalline $Al_2TiO_5$ ceramics with low thermal expansion by fusion in an electric arc furnance was investigated. The thermal expansion curves of $Al_2TiO_5$ ceramics were lowered because of microcracks caused by the strong thermal expansion anisotropy of the crystal axes and were accompanied by hysteresis curves. These phenomena are explained by the opening and closing of microcracks. The difference in microcracking temperatures of dilatometric cooling curves in the range of 400~$620^{\circ}C$ is caused by the difference in sintering temperature, grain size and stabilization status.

  • PDF