• Title/Summary/Keyword: Expanded Tube

Search Result 80, Processing Time 0.029 seconds

The Optimization Processing on a Expanded Tube Using Mini-Tab (Mini-Tab을 이용한 D-Tube 확관 최적 공정 설계)

  • Joo, Won-Kyung;Kwun, Yong-Gu;Bae, Sung-In;Song, Jung-Il
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.751-755
    • /
    • 2007
  • The purpose of this study is to find the optimization processing on expanded tube using Taguchi method which was generally used to analyze the effects of various control factors. Mini-Tab is a good for program that is making a selection using Taguchi method. The results of experimental test and analysis are as follows. Optimization processing on a expanded tube is dependent on lubrication condition. The slight eccentricity of expanded tube was obtained a good results on the expanded tube. When expending processing on the expanded tube was performed, the test specimens were almost unaffected by changing pressure loading. The tendencies of test results were related to lubrication condition and eccentricity in expending processing. As a result, a proper lubrication condition and eccentricity in the step of design will improve the optimization processing of expanded tube.

  • PDF

Design of a Mandrel for Expansion of the Tube of the Heat Exchanger (열교환기 튜브확관을 위한 맨드렐 설계)

  • Kang, H.S.;Kim, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.430-434
    • /
    • 2004
  • Specifically designed mandrel is needed to expand tube of the heat exchanger with inner grooves. Configuration of the expanded tube depends upon the shape and feeding velocity of the mandrel. 3D simulation software LS-DYNA was used to obtain optimum design conditions of the mandrel. We show how configuration of the expanded tube varies with different design parameters such as the approaching angle, diameter , and the feeding velocity of the mandrel. Material property data for analysis were obtained through experiments with SHPB ( Split Hopkinson Pressure Bars ).

  • PDF

NUMERICAL ANALYSIS ON PRESSURE DROP IN EXPANDED BED ACCORDING TO TUBE-TO-PARTICLE RATIOS AND REYNOLDS NUMBERS (Expanded bed에서 레이놀즈수와 직경입자비에 따른 압력강하 특성에 관한 수치적 연구)

  • Bae, S.W.;Sung, H.G.;Roh, T.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.62-65
    • /
    • 2011
  • Characteristics of the pressure drop in an expanded bed have been compared to those in a packed bed for numerical study of the interphase drag in gas-particle flows. A numerical analysis of the pressure drop by the particle drag has been conducted according to the tube-to-particle diameter ratios and Reynolds numbers for comparison. As the tube-to-particle diameter ratios increase at the same Reynolds number, the pressure drop tends to converge. It has been confirmed that characteristics of the pressure drop in the expanded bed are similar to those in the packed bed.

Experimental investigation of friction in expansion zone of tube hydroforming with material and lubricant (튜브 액압성형 공정의 확관영역에서 소재 및 윤활에 따른 마찰 특성의 실험적 연구)

  • Lee, G.Y.;Yim, H.S.;Lee, S.M.;Yi, H.K.;Chung, G.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.359-362
    • /
    • 2008
  • In this study, friction test was proposed to obtain coefficient of friction between tube and die in expansion zone of tube hydroforming and friction coefficients were evaluated at different materials, viscosity of lubricants and internal pressures. For this study, STKM11A and SUS tubes were prepared. The tube was expanded by an internal pressure against the tool wall. The tube was expanded by an internal pressure against the tool wall. By pushing the tube through the tool, a friction force at the contact surface between the tube and the tool occurs. From the measured geometries and FE analysis, the friction coefficients between tube and die at the expansion zone in tubular hydroforming can be estimated. The effects of the various internal pressures, viscosity of lubricants, tube materials and tube thickness on friction coefficients are discussed.

  • PDF

The Evaluation of Tube to Tubesheet Joint Part on Nuclear S/G (원자력 증기발생기 튜브/튜브시트 확관방법별 특성평가)

  • 심상한;배강국;김인수
    • Proceedings of the KWS Conference
    • /
    • 1996.05a
    • /
    • pp.34-37
    • /
    • 1996
  • The expanding method of tube to tubesheet joint part on neclear steam generators are classified into three classes of roller expanding, explosive expanding and hydraulic expanding. After the expanded Mock-Up specimen are made by the three expanding method. The general properties, microstructure/microvickers hardness, pull-out strength, hydraulic leak pressure, of tube to tubesheet joint part were inspected. and We evaluated the operation efficiency of expansion, reproduction of expanded joint about three expanding method. Through the overall evaluation of tube to tubesheet joint part, The hydraukic expanding and explosive expanding could be certificated more useful expanding method.

  • PDF

Methodology of Non-Destructive Examinations on Hydraulic Expansion Region of Steam Generator Tubes (증기발생기 세관 수압확관부 비파괴검사 방법론)

  • Kim, Chang-Soo;Jung, Nam-Du;Lee, Sang-Hoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.29-33
    • /
    • 2008
  • As the measures of nuclear power plant utilities and manufacturers to reduce the defects of tube expansion region during manufacturing steam generators, many types of NDEs(Non-Destructive Examinations) are conducted to inspect the expansion region. The expansion region of tube is subject to degrade because of stress concentration induced by tube expansion, sludge pile and high temperature. So the inspections for tube expansion region have been reinforced. Liquid penetrant test, helium leak test, Bobbin profile test and hydraulic test are performed to confirm the integrity of tube expanded by hydraulic expansion method. Liquid penetrant test and helium leak test are used to inspect seal weld region on tubesheet end part. Bobbin Profile test is used to inspect fully the expanded region of steam generator tube. Hydraulic test finally verifies the integrity of seal weld region on tubesheet end part.

  • PDF

Simulation and Analysis of ECT Signals Obtained at Tubesheet and Tube Expansion Area

  • Song, Sung-Chul;Lee, Yun-Tai;Jung, Hee-Sung;Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.174-180
    • /
    • 2006
  • Steam generator (SG) tubes are expanded inside tubesheet holes by using explosive or hydraulic methods to be fixed in a tubesheet. In the tube expansion process, it is important to minimize the crevice gap between expanded tube and tube sheet. In this paper, absolute and differential signals are computed by a numerical method for several different locations of tube expansion inside and outside a tubesheet and signal variations due to tubesheet, tube expansion and operating frequencies are observed. Results show that low frequency is good for detecting tubesheet location in both types of signals and high frequency is suitable for sizing of tube diameter as well as the detection of transition region. Also learned is that the absolute signal is good for measuring tube diameter, while the differential signal is good for locating the top of tubesheet and both ends of the transition region. In the case of mingled anomaly with tube expansion and tubesheet, low frequency inspection is found to be useful to analyze the mixed signal.

Wolsong 3&4 Steam Generator Tube Inspection (월성 3,4호기 증기발생기 전열관 검사)

  • Jang, Kyoung-Sik;Kwon, Dong-Ki;Choi, Jin-Hyuk;Son, Tai-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.859-866
    • /
    • 2001
  • During the Pre-service Inspection for Wolsong Unit 3&4 in 1997/1998 respectively, 17 Distorted Roll Transition indications(over expanded beyond tubesheet secondary face) were identified at the Unit 4 (S/G B, D). Six(6) tubes out of these tubes were plugged in 1998. However the first Periodic Inspection identified additional 110 indications in 1999 and 2000. The additionally identified 110 indication call, not reported at the Pre-service Inspection, are; 2 Not-Finally-Expanded-Tubes and 108 Distorted Roll Transition tubes. Design limit of each Steam Generator tube Plugging is 6.4%. Plugging was performed by the Steam Generator manufacturer under the warranty. When Distorted Roll Transition indications were first identified on the Unit 4 in 1998 the degree of Over-expansion was measured using an inner dial-gage to make the disposition of Nonconformance report. 2 Not-Finally-Expanded-Tubes were plugged and 10 tubes out of 108 Distorted Roll Transition Tubes were also plugged as a preventive measure.

  • PDF

A Study on the Tube/tubesheet Interface in the Heat Exchangers Jointed by Explosive Bonding (폭발접합된 열교환기류 튜브와 튜브시트의 계면 특성에 관한 고찰)

  • 이병일;공창식;이상철
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.38-47
    • /
    • 2000
  • Characteristics of the interface between tube and tube sheet which were formed by explosive expansion and roll expansion, have been studied in the research. The results are as follows: Optimum amounts of explosives for the expansion of Alloy 600 (19.05mm and 15.88mm) were found to be RDX 3.5-8.5g/m. Because explosive expansion caused les strain hardening and increased bounding strength, characteristics of the explosively expanded were better than those of mechanically expanded. As the transition region of the explosive expansion is inactive, the resistance to the stress corrosion cracking increases by 30∼40% compared to the roll and hydraulic expansion.

  • PDF

Experimental investigation of friction in guide zone of tube hydroforming with material and lubricant (튜브 액압성형 공정의 가이드영역에서 소재 및 윤활에 따른 마찰 특성의 실험적 연구)

  • Yi, H.K.;Yim, H.S.;Lee, G.Y.;Lee, S.M.;Chung, C.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.83-86
    • /
    • 2008
  • In this study, friction test was proposed to obtain coefficient of friction between tube and die in guide zone of tube hydroforming and friction coefficients were evaluated at different materials, viscosity of lubricants and internal pressures. For this study, STKM11A and SUS tubes were prepared. The tube was expanded by an internal pressure against the tool wall. By pushing the tube through the tool, a friction force at the contact surface between the tube and the tool occurs From the recorded axial feeding forces, the friction coefficients between tube and die at the guide zone in tubular hydroforming can be estimated. The effects of the various internal pressures, viscosity of lubricants, tube materials, tube size and die coating on the friction forces and friction coefficients are discussed.

  • PDF