• Title/Summary/Keyword: Exothermic characteristics

Search Result 106, Processing Time 0.031 seconds

Thermal Decomposition Characteristics of Azo compounds (아조(Azo)화합물 열분해특성)

  • Kim, Kwan-Eung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • This study was investigated the thermal decomposition characteristics of azo type sponge blowing agent azodicarbonamide(ADCA) using differential scanning calorimeter(DSC). The experimental results showed that the exothermic onset $temperatures(T_{o})$ for ADCA were about $201{\sim}206^{\circ}C$ and evolution heats(Q) were about $144{\sim}150cal/g$. The exothermic onset $temperatures(T_{o})$, exothermic maximum $temperature(T_{m})$ and exothermic final $temperature(T_{f})$ were decreased by decreasing particle size of ADCA and evolution heats(Q) were increased with it. $T_{o}$ and Q for $6.1{\sim}7.2{\mu}m$ ADCA were increased by increasing heating rate at constant sample weight and activation energy was about 37.29kcal/mol. A positive gas pressure was employed in the elucidation of the decomposition behavior of ADCA because it sublimes during linear heating at atmospheric pressure. $T_{o}$ and Q of ADCA tended to increase with a pressure in air or nitrogen. In the case of azo dye, experimental results showed that $T_{o}$ were about $280{\sim}420^{\circ}C$ and Q were about $2{\sim}30cal/g$.

A Study on the Thermal Decomposition Characteristics of Nitrophenylhydrazine (니트로페닐하이드라진의 열분해 특성에 관한 연구)

  • 김관응;이근원
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.75-79
    • /
    • 2001
  • For handling and storage of reactive chemicals, the hazard evaluations have been extremely important. In the chemical industry, the most concerns are focused on the thermal harzards such as runaway reactions and thermal decompositions, which are mostly governed by thermodynamics and reaction kinetics or these reactive chemical in the system. This study no investigated the thermal decomposition characteristics of nitrophenylhydrazine isomers by using differential scanning calorimeter(DSC) and accelerating rate calorimeter(ARC). Experimental results showed that exothermic onset-temperatures in nitrophenylhydrazine(NPH) isomers were about 160-$210^{\circ}C$ by DSC and 100-$150^{\circ}C$ by ARC. The decomposition temperature acquired by ARC was about 50-$60^{\circ}C$ lower than that by DSC. Reaction heats were about 40-100cal/g by DSC and 330-750ca1/g by ARC. While ortho isomer of NPH show two distinct exothermic peaks, para isomer shows a single peak in DSC curves. The first exothermic peak for 2-NPH is mainly due to intramolecular dehydration forming 1-hydroxybenzotriazole(HOBT) and the second exothermic peak is mainly due to the decomposition of HOBT formed in the first step of decomposition. The exothermin peak in the DSC curve for 4-NPH is mainly due to dissociation of hydrazino and nitro groups.

  • PDF

A Study on the Exothermic Properties of ITO/Ag/ITO Multilayer Transparent Electrode Depending on Metal Layer Thickness (금속층 두께에 따른 ITO/Ag/ITO 다층 투명 전극의 발열 특성 연구)

  • Min, Hye-Jin;Kang, Ye-Jina;Son, Hye-Won;Sin, So-Hyun;Hwang, Min-Ho;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.37-43
    • /
    • 2022
  • In this study, we investigated the optical, electrical and exothermic characteristics of ITO/Ag/ITO multilayer structures prepared with various Ag thicknesses on quartz and PI substrates. The transparent conducting properties of the ITO/Ag/ITO multilayer films depended on the thickness of the mid-layer metal film. The ITO/Ag (14 nm)/ITO showed the highest Haccke's figure of merit (FOM) of approximately 19.3×10-3 Ω-1. In addition, the exothermic property depended on the substrate. For an applied voltage of 3.7 V, the ITO/Ag (14 nm)/ITO multilayers on quartz and PI substrates were heated up to 110℃ and 200℃, respectively. The bending tests demonstrated a comparable flexibility of the ITO/Ag/IT multilayer to other transparent electrodes, indicating the potential of ITO/Ag/ITO multilayer as a flexible transparent conducting heater.

Carbonization Characteristics of Phenolic Resin Deteriorated by Tracking (트래킹에 의해 열화된 페놀수지의 탄화 특성)

  • 송길목;최충석;노영수;곽희로
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This paper describes the carbonization characteristics of a phenolic resin deteriorated by tracking under the environment of a fire. In the experiment, a liquids droplet of 1[%] NaCl was dripped on the phenolic resin to cause a tracking with 110[V], 220[V] voltages applied. It can be addressed from the experimental results that when an insulator is carbonized by an external fire, its structure is amorphous. If an insulator is carbonized by electrical cause, on the other hand, its structure would be crystalline. In order to observe the surface change of the phenolic resin, the tracking process was analyzed by using SEM. In the case that the materials are carbonized under heat or fire, the exothermic peak appears around 500[$^{\circ}C$]. This is one of the important factors to determine the cause of fires. As a result of DTA, the exothermic peaks of an untreated sample showed at 333.4[$^{\circ}C$], 495.7[$^{\circ}C$] but those of a sample deteriorated by tracking appeared at 430.6[$^{\circ}C$], 457.6[$^{\circ}C$] in a voltage of 110[V], and at 456.2[$^{\circ}C$], 619.7[$^{\circ}C$] in a voltage of 220[V]. It is possible, therefore, to distinguish a virgin sample from carbonized samples(graphite) by the exothermic peak.

Effect of Chloride-containing Deicer on the Thermal Charateristics and Skid Resistance of Concrete (염화물을 함유한 제설제가 콘크리트의 열 특성과 미끄럼저항성에 미치는 영향에 관한 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.509-512
    • /
    • 2004
  • This research is targeting that estimate the effect on cement concrete pavement with type of chloride deicers. In order to this study objective, when chloride deicers were spread on road surface, thermal characteristics test was conducted. Also, skid resistance test according to types and concentration of chloride deicier, road surface conditions were investigated. As a test results, thermal characteristics with kind of chloride deicier could know that sodium chloride(NaCl) is exothermic reactive material, calcium chloride$(CaCl_2)$ is endothermic reactive material. And, in case of mixed salt of the calcium and sodium chloride, it could know that can change to the exothermic or endothermic reaction according to dosage ratios. Skid value by British Pendulum Tester(BPT) has shown that it is seldom difference between the types($CaCl_2$, NaCl, mixed salt) and solution concentrations(0.5, 0.8, 1.0, 4.0, $10\%$) of chloride deicier comparing with tap water except mixed salt($10\%$ solution concentration).

  • PDF

Analysis of Discharge Characteristics and Fire Risk of Mobile Phone Batteries according to the Concentration of Salt Water (염수농도에 따른 휴대폰 배터리의 방전특성과 화재 위험성 분석)

  • Woo, Jin-Su;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.66-71
    • /
    • 2020
  • The process of discharging batteries using salt water, when used for the disposal of a lithium-ion (Li-ion) batteries, is likely to cause a fire. However, there is a dearth of studies in the literature on the risk of fire while discharging mobile phone batteries in salt water. In order to investigate the possibility of fire by elucidating the discharge characteristics and the generation of heat, we conducted experiments by varying the concentration of the salt water, number of overlapping batteries, and type of the mobile phone batteries used as experimental specimen. The discharging voltage and the temperature of the batteries were measured, and the fire risk was predicted by analyzing the data. The results of the experiment showed that the higher the salt water concentration, the greater the discharge value of the mobile phone battery and the higher the exothermic temperature. Moreover, the exothermic temperatures of the overlapping batteries were higher than that of the single battery submerged in salt water. The highest exothermic temperature points of the battery occurred at the positive and negative poles.

A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress (열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구)

  • 최충석;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.164-170
    • /
    • 2003
  • In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

  • PDF

The Analysis of the Carbonization Properties between RCD Source Terminals Deteriorated by Tracking (누전차단기 외함 전원측 단자사이의 트래킹에 의한 탄화특성 분석)

  • 최충석;송길목;김동우
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, we studied on the characteristics of RCD(Residual Current Device) case deteriorated by tracking, and compared the tracked samples between in the site of fire($S_1$) and in the reappearance experiment($E_1$). This experiment is applied to IEC Publ. 112 method. Electrical fire by tracking occurred after scintillation and dry-band generated. The insulation resistance between source terminals of RCD case was about 25.7Ω in $E_1$ and the resistance was about 58.6Ω in $S_1$.The exothermic peaks of $E_1$ appeared at $491.0^{\circ}C$ and $603.2^{\circ}C$. The exothermic peak at $603.2^{\circ}C$ was shown by tracking. And the exothermic peak of $S_1$ appeared at $593.1^{\circ}C$. In spectrum of $S_1$ and $E_1$, absorption peak didn't appear at near 1590 cm$^{-1}$ .

An Evaluation of Thermal Stability of Raw Materials in the Vinyl Acetate Polymerization Process (비닐아세테이트 중합공정에서 원료물질의 열적 안정성 평가)

  • Lee, Keun-Won;Han, In-Soo;Lee, Jung-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.61-65
    • /
    • 2010
  • Most of the chemical reactions performed in the chemical industry are exothermic, meaning that thermal energy is released during the reaction. It is also important to understand the thermal hazards such as thermal stabilities and runaway reactions, which are governed by thermodynamics and reaction kinetics of the mixed materials. The paper was described the evaluation of thermal behavior caused by an exothermic batch process in manufacture of the vinyl acetate resin. The aim of the study was to evaluate the thermal stabilities of raw materials with operating conditions such as a reaction inhibitor, heating rate, reaction atmosphere and the mount of methanol charged in the vinyl acetate polymerization process. The experiments were performed in the differential scanning calorimeter(DSC), C 80 calorimeter, and thermal screening unit($TS^u$). It was suggested that we should provide the thermal characteristics for raw materials to present safe precautions with operating conditions in the vinyl acetate polymerization process.

A Study on Heat Storage System Using Calcined Dolomite - Numerical Analysis of Heat Transfer in Calcined Dolomite Hydration Pocked Bed - (소성Dolomite 수화물계의 축열시스템에 관한 연구 - 소성Dolomite 수화반응층의 전열해석 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.9-21
    • /
    • 2002
  • To develope chemical heat pump using available energy sources, solar heat and other kinds of waste thermal energy, we have studied the heat transfer rate in cylindrical bed reactor packed with calcined Dolomite. Two dimensional (radial and circumferential) Partial differential equations, concerning heat and mass transfer in packed bed of calcined Dolomite, are solved numerically to describe the characteristics of the reaction of calcined Dolomite and heat transfer. The results obtained by numerical analysis about two dimensional profiles of temperature and conversion of reactant in the packed bed reactor and the amount of exothermic heat released from the reactor are follows. It was found that all of calcined Dolomite packed bed kept the reaction temperature of about 750K throughout the entire part of the bed, immediately after the steam was introduced exothermic reaction of hydration was proceeded from the packed bed inpu to output and from wall side to center. The rate of thermochemical reaction depends on the temperature and concentration and it is also governed by the boundary conditions and heat transfer rate in the particle packed bed.