• Title/Summary/Keyword: Existing Concrete Structures

Search Result 709, Processing Time 0.025 seconds

Natural time period equations for moment resisting reinforced concrete structures comprising hollow sections

  • Prajapati, Satya Sundar;Far, Harry;Aghayarzadeh, Mehdi
    • Computers and Concrete
    • /
    • v.26 no.4
    • /
    • pp.317-325
    • /
    • 2020
  • A precise estimation of the natural time period of buildings improves design quality, causes a significant reduction of the buildings' weight, and eventually leads to a cost-effective design. In this study, in order to optimise the reinforced concrete frames design, some symmetrical and unsymmetrical buildings composed of solid and hollow members have been simulated using finite element software SAP 2000. In numerical models, different parameters such as overturning moment, story drift, deflection, base reactions, and stiffness of the buildings were investigated and the results have been compared with strength and serviceability limit criteria proposed by Australian Standard (AS 3600 2018). Comparing the results of the numerical modelling with existing standards and performing a cost analysis proved the merits of hollow box sections compared to solid sections. Finally, based on numerical simulation results, two equations for natural time period of moment resisting reinforced concrete buildings have been presented. Both derived equations reflected higher degree of correlation and reliability with different complexities of building when compared with existing standards and relationships provided by other scholars. Therefore, these equations will assist practicing engineers to predict elastic behaivour of structures more precisely.

An Evaluation of Structural Performance of Reinforced Concrete Column Retrofitted with Grid Type Unit Details of Jacketing Method (격자형 유닛 상세를 가진 단면증설공법으로 보강된 철근콘크리트 기둥의 구조성능평가)

  • Moon, Hong Bi;Lee, Jeong In;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.

Bond strength characterization and estimation of steel fibre reinforced polymer - concrete composites

  • Jahangir, Hashem;Eidgahee, Danial Rezazadeh;Esfahani, Mohammad Reza
    • Steel and Composite Structures
    • /
    • v.44 no.6
    • /
    • pp.803-816
    • /
    • 2022
  • Composite materials are effective in forming externally bonded reinforcements which find applications related to existing structures repair, attributed to their high strength-to-weight ratio and ease of installation. Among various composites, fibre reinforced polymers (FRP) have somewhat been largely accepted as a commonly utilized composite for such purposes. It is only recently that steel fibres have been considered as additional members of the FRP fibre family, intuitively termed as steel reinforced polymer (SRP). Owing to its low cost and permissibility of fibre bending at sharp corners, SRP is rapidly becoming a viable contender to other FRP systems. This paper investigates the bond behaviour of SRP-concrete joints with different bonded lengths (50, 75, 100, 150 and 300 mm) and widths (15, 30, 40, 50, and 75 mm) using single-lap shear tests. The experimental specimens contain SRP strips with a fixed density of steel fibres (0.472 cords/mm) bonded to the face of concrete prisms. The load responses were obtained and compared in terms of corresponding load and slip boundaries of the constant region and the peak loads. The failure modes of SRP composites are discussed, and the range of effective bonded length is evaluated herein. In the end, a new analytical model was proposed to estimate the SRP-concrete bond strength using a genetic algorithm, which outperforms 22 existing FRP-concrete bond strength models.

Flexural/shear strength of RC beams with longitudinal FRP bars An analytical approach

  • Kosmidou, Parthena-Maria K.;Chalioris, Constantin E.;Karayannis, Chris G.
    • Computers and Concrete
    • /
    • v.22 no.6
    • /
    • pp.573-592
    • /
    • 2018
  • An analytical methodology for the calculation of the flexural and the shear capacity of concrete members with Fibre-Reinforced-Polymer (FRP) bars as tensional reinforcement is proposed. The flexural analysis is initially based on the design provisions of ACI 440.1R-15 which have properly been modified to develop general charts that simplify computations and provide hand calculations. The specially developed charts include non-dimensional variables and can easily be applied in sections with various geometrical properties, concrete grade and FRP properties. The proposed shear model combines three theoretical considerations to facilitate calculations. A unified flexural/shear approach is developed in flow chart which can be used to estimate the ultimate strength and the expected failure mode of a concrete beam reinforced with longitudinal FRP bars, with or without transverse reinforcement. The proposed methodology is verified using existing experimental data of 138 beams from the literature, and it predicts the load-bearing capacity and the failure mode with satisfactory accuracy.

Reliability Assessment of Concrete Beams Reinforced with GFRP Bars (FRP 보강근을 사용한 콘크리트 보의 신뢰성 해석)

  • Nam, Ho-Yun;Seo, Dae-Won;Han, Byum-Seok;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.185-188
    • /
    • 2008
  • Fiber reinforced polymer(FRP) bars are proving to be a valuable solution in the corrosion problem of steel reinforced concrete structures. As such, a number of guidelines for their use have been developed. These guidelines are primarily based on modifications to existing codes of practice for steel reinforced concrete structures. These guidelines are also similar in that though the design equations are presented in the partial factor formats that are often used in probability based design, they are not true probabilistic codes. Instead, they typically make use of already existing design factors for loads and resistances. Thus, when concrete structures reinforced FRP bars are designed, the structural reliability levels are not known. This paper investigates uncertainties of concrete beams reinforced with GFRP bars. Also, the structural reliability levels are evaluated for the flexural failure mode.

  • PDF

Mechanically fastened shear connectors in prefabricated concrete slabs - experimental analysis

  • Gluhovic, Nina;Markovic, Zlatko;Spremic, Milan;Pavlovic, Marko
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.369-381
    • /
    • 2020
  • Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

Influence of openings of infill wall on seismic vulnerability of existing RC structures

  • Dilmac, Hakan
    • Structural Engineering and Mechanics
    • /
    • v.75 no.2
    • /
    • pp.211-227
    • /
    • 2020
  • The contribution of infill wall is generally not considered in the structural analysis of reinforced concrete (RC) structures due to the lack of knowledge of the complex behavior of the infilled frame of RC structures. However, one of the significant factors affecting structural behavior and earthquake performance of RC structures is the infill wall. Considering structural and architectural features of RC structures, any infill wall may have openings with different amounts and aspect ratios. In the present study, the influence of infill walls with different opening rates on the structural behaviors and earthquake performance of existing RC structures were evaluated. Therefore, the change in the opening ratio in the infill wall has been investigated for monitoring the change in structural behavior and performance of the RC structures. The earthquake performance levels of existing RC structures with different structural properties were determined by detecting the damage levels of load-carrying components. The results of the analyzes indicate that the infill wall can completely change the distribution of column and beam damage level. It was observed that the openings in the walls had serious impact on the parameters affecting the behavior and earthquake performance of the RC structures. The infill walls have a beneficial effect on the earthquake performance of RC structures, provided they are placed regularly and there are appropriate openings rate throughout the RC structures and they do not cause structural irregularities.

Practical applicable model for estimating the carbonation depth in fly-ash based concrete structures by utilizing adaptive neuro-fuzzy inference system

  • Aman Kumar;Harish Chandra Arora;Nishant Raj Kapoor;Denise-Penelope N. Kontoni;Krishna Kumar;Hashem Jahangir;Bharat Bhushan
    • Computers and Concrete
    • /
    • v.32 no.2
    • /
    • pp.119-138
    • /
    • 2023
  • Concrete carbonation is a prevalent phenomenon that leads to steel reinforcement corrosion in reinforced concrete (RC) structures, thereby decreasing their service life as well as durability. The process of carbonation results in a lower pH level of concrete, resulting in an acidic environment with a pH value below 12. This acidic environment initiates and accelerates the corrosion of steel reinforcement in concrete, rendering it more susceptible to damage and ultimately weakening the overall structural integrity of the RC system. Lower pH values might cause damage to the protective coating of steel, also known as the passive film, thus speeding up the process of corrosion. It is essential to estimate the carbonation factor to reduce the deterioration in concrete structures. A lot of work has gone into developing a carbonation model that is precise and efficient that takes both internal and external factors into account. This study presents an ML-based adaptive-neuro fuzzy inference system (ANFIS) approach to predict the carbonation depth of fly ash (FA)-based concrete structures. Cement content, FA, water-cement ratio, relative humidity, duration, and CO2 level have been used as input parameters to develop the ANFIS model. Six performance indices have been used for finding the accuracy of the developed model and two analytical models. The outcome of the ANFIS model has also been compared with the other models used in this study. The prediction results show that the ANFIS model outperforms analytical models with R-value, MAE, RMSE, and Nash-Sutcliffe efficiency index values of 0.9951, 0.7255 mm, 1.2346 mm, and 0.9957, respectively. Surface plots and sensitivity analysis have also been performed to identify the repercussion of individual features on the carbonation depth of FA-based concrete structures. The developed ANFIS-based model is simple, easy to use, and cost-effective with good accuracy as compared to existing models.

Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening Performance of Reinforced Concrete Beams - (Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 보의 보강성능 평가 -)

  • Lee, Kang-Seok;Son, Young-Sun;Byeon, In-Hee;Lee, Moon-Sung;Na, Jung-Min;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.133-136
    • /
    • 2006
  • The main purpose of this study is to develop a Sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing carbon or glass shot fibers and the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the Sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In this study, a series of experiments are carried out to evaluate the strengthening effects of the flexural and shear concret beams strengthened with the Sprayed FRP method. The results revealed that the strengthening effects of the flexural and shear specimens are similar, compared to those of the FRP sheet.

  • PDF

Analysis of Crack Localization in Fracture of Concrete Structures (콘크리트 구조물의 파괴에서의 국소화된 균열진행해석)

  • Koo, Ja-Choon;Song, Ha-Won;Shim, Byul;Woo, Seung-Min;Byun, Keun-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.583-586
    • /
    • 2000
  • In this paper, the embedded crack approach that crack is modeled by discontinuous line inside finite element is applied for localized progressive fracture analyses. The algorithm for progressive fracture analyses of concrete structure are enhanced by introducing nonlinear softening curve and unloading algorithm of tension-softening curve which can simulate localized fracture of concrete. The failure analysis results ar compared with existing test results for varification.

  • PDF