• Title/Summary/Keyword: Exhaust pollutants

Search Result 161, Processing Time 0.028 seconds

A study on the ventilation characteristics and design of transverse ventilation system for road tunnel (도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.305-315
    • /
    • 2018
  • In this study, the ventilation characteristics and the relationships between the required ventilation flow rate and the ventilation system flow rate was investigated by numerical method for the optimum design of the transverse ventilation and semi-transverse ventilation system in road tunnels. The following results were obtained. In supply exhaust transverse ventilation system, the system supply-exhaust air flow rate is theoretically equal to the difference between the required ventilation flow rate and natural ventilation flow rate. However, it is shown that it increases by about 10% in the analysis results. And, in the case of the longitudinal air flow rate is increased by installed jet fans, ventilation system air flow rate is reduced. However, as the longitudinal air flow rate increases, the concentration of pollutants in the tunnel decreases, so the exhaust effect of pollutants decreases, and the effect of reducing the system air flow rate is decreased. In case of semi-transverse with only air supply, ventilation system air flow rate is equal to required ventilation air flow rate when tunnel inlet velocity is negative, but results is shown it is increased within about 13.3%. Also, it was found that ventilation effect can not be expected even if the jet fans are increased when the tunnel inlet velocity is negative.

Experimental Study on Structure Characteristics of Particulate Matter emitted from Ship at Various Sampling Conditions (다양한 샘플링 조건에 따른 선박 배기가스 내 입자상물질의 구조 특성에 관한 실험 연구)

  • Lee, Won-Ju;Jang, Se-Hyun;Kim, Sung-Yoon;Kang, Mu-Kyoung;Chun, Kang-Woo;Cho, Kwon-Hae;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.547-553
    • /
    • 2016
  • Black carbon (BC) contained in particulate matter (PM) originating from the exhaust gases of ships' diesel engines has been receiving great attention as a cause of glacial melting and warming in the polar regions. In this study, we took samples from various locations of PM emitted from the training ship (T/S) HANBADA's main engine, in cooperation with the Korea Maritime and Ocean University. We analyzed the structure and characteristics of these samples using high-resolution transmission electron microscopy (HR-TEM) and applied our findings as fundamental research for developing PM reduction technology. We also employed our results to determine appropriate preemptive action to meet upcoming PM/BC regulations. In addition, we confirmed the emission trend of pollutants from exhaust gases under various engine operating conditions using an exhaust gas analyzer. Results obtained from the analysis of HR-TEM images showed that the structure of the PM is chain-like wispy agglomerates consisting of a number of individual spherical particles. As the sampling location was moved away from the turbo charger (T/C) towards the funnel, more condensates were observed at a low temperature and the molecular structure of the PM lost its characteristic BC structure as an amorphous structure gradually appeared. Furthermore, through the analysis of exhaust gases, we predicted a decrease in PM concentration in the exhaust stream as engine rpm increase.

Diesel Exhaust Particle Exposure and its Pulmonary Function Effects (경유차량 배출물질의 노출과 폐기능의 상관성 연구)

  • Lee, Yong-Jin;Kim, Da-Hye;Kim, Soo-Hwan;Kim, Jeong-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.457-468
    • /
    • 2016
  • Traffic-related air pollutants and particulates from diesel exhaust cause for increasing respiratory health problem. Recent epidemiologic studies have reported adverse effects of urban air pollution on various aspects of respiratory health. Bus or truck terminal workers have high probability of exposure to diesel exhaust particle than general office worker. This study was designed to evaluate the relationship between pulmonary function of people who working at the high-density area of diesel vehicles and pulmonary function of people who working at general office in Seoul. So, this study explored the effects on people with exposure to diesel traffic or exposure to diesel traffic, through the pulmonary function test (PFT). There were significant difference in Forced Vital Capacity (FVC) and Forced Expiratory Volume in 1 second ($FEV_1$) between high-exposure group and control. High-exposure to diesel particle were increased risk of reduction in pulmonary function in this study. These results provide the necessity additional research that manage people who working at the high-density area of diesel vehicles.

Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter (겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염)

  • Kim, Jong Bum;Lee, Gwangjae;Ryu, Sung Hee;Lee, Jae Young;Woo, Sung-Ho;Lee, Seung-Bok;Kim, Kyung Hwan;Yun, Seong-Taek;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

Emission Prediction from Naval Ship Main Propulsive Diesel Engine under Steady Navigation (정속항해 시 함정 주 추진 디젤엔진의 배기가스 배출량 예측)

  • Lee, Hyung-Min;Park, Rang-Eun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.788-793
    • /
    • 2012
  • This study was focused on the estimations of air pollutants, such as PM(Particulate matters), SOx(Sulfur Oxides), $CO_2$(Carbon diOxides) and NOx(Nitrogen Oxides), from a diesel propulsion engine installed on a naval vessel. Legislative and regulatory actions for exhaust emissions from ships are being strengthened in international communities and national governments to protect human health and the environment. In this context, various technologies have been developed from all of the nations of the world to meet strict standards. These regulations are based on commercial ship applications and according to size, but are not suitable for military naval vessels, which have much different engine operating conditions and hull architectures. Additionally, there is no international emission control system for military ships. Emission factors have been updated for commercial ship types from work at various research institutes; however, it is difficult to develop emission factors for military vessels because of their characteristics. In this paper, exhaust emissions from diesel engines installed on naval vessels under steady navigation condition were estimated with emission inventory methodology applied to ocean going vessels using fuel-based methods and fuel sulfur content analysis.

A Study on Exhaust Gas Characteristics of Heavy-duty Diesel Engines through Actual Vehicle Application of Non-influenced Temperature Condition Type Active Regeneration Method (온도조건 비영향형 복합재생방식 DPF의 실차적용을 통한 대형디젤기관의 배출가스 특성 연구)

  • Yun chul Lee;Sang ki Oh
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.53-59
    • /
    • 2024
  • Cars are one of the main causes of air pollution in large cities, and 34.6% of domestic air pollution emissions come from mobile sources, of which cars account for 69.6%. In particular, the importance of nitrogen oxides (NOx) and particulate matter (PM), which are major pollutants in diesel vehicles, is increasing due to their high contribution to emissions. Therefore, in this study, the problem of natural regeneration caused by low exhaust gas temperature during low speed and low load operation was solved by applying a complex regeneration DPF that is not affected by temperature conditions to large diesel vehicles with higher driving time and engine displacement than small and medium-sized vehicles. And the feasibility of application to large diesel vehicles was reviewed by measuring the emission reduction efficiency. As a result of the reduction efficiency test on the actual vehicle durability product, PM showed a reduction efficiency of 84% to 86%, and the reduction efficiency of gaseous substances showed a high reduction efficiency of over 90%. The actual vehicle applicability test was completed with three driving patterns: village bus vehicle, police car, and road-going construction equipment vehicle, and no device problems occurred until the end of the test. Both load and no-load smoke measurement results showed a smoke reduction efficiency of over 96%.

Comparison of Mutagenic Activities of Various Ultra-Fine Particles

  • Park, Chang Gyun;Cho, Hyun Ki;Shin, Han Jae;Park, Ki Hong;Lim, Heung Bin
    • Toxicological Research
    • /
    • v.34 no.2
    • /
    • pp.163-172
    • /
    • 2018
  • Air pollution is increasing, along with consumption of fossil fuels such as coal and diesel gas. Air pollutants are known to be a major cause of respiratory-related illness and death, however, there are few reports on the genotoxic characterization of diverse air pollutants in Korea. In this study, we investigated the mutagenic activity of various particles such as diesel exhaust particles (DEP), combustion of rice straw (RSC), pine stem (PSC), and coal (CC), tunnel dust (TD), and road side dust (RD). Ultra-fine particles (UFPs) were collected by the glass fiber filter pad. Then, we performed a chemical analysis to see each of the component features of each particulate matter. The mutagenicity of various UFPs was determined by the Ames test with four Salmonella typhimurium strains with or without metabolic activation. The optimal concentrations of UFPs were selected based on result of a concentration decision test. Moreover, in order to compare relative mutagenicity among UFPs, we selected and tested DEP as mutation reference. DEP, RSC, and PSC induced concentration-dependent increases in revertant colony numbers with TA98, TA100, and TA1537 strains in the absence and presence of metabolic activation. DEP showed the highest specific activity among the particulate matters. In this study, we conclude that DEP, RSC, PSC, and TD displayed varying degrees of mutagenicity, and these results suggest that the mutagenicity of these air pollutants is associated with the presence of polycyclic aromatic hydrocarbons (PAHs) in these particulate matters.

Estimation of Exhaust NOx Emission for Marine Engines (선박엔진의 NOx 배출량 산정)

  • 김대식;엄명도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.441-445
    • /
    • 2000
  • Considering international status of our country as world class ship builder and geographical characteristics encircled by sea in three facets, controlling of air pollutants emission from marine engines becomes more and more important issue in recent days. Implementation of immediate pollutants emission control regulation and standardization of test and certification procedure are required to reduce air pollution from marine engines. But cost increments due to additional equipment of emission control device and development and certification test expenses as well as depreciation of fuel economy should be considered. To satisfy those air pollution reduction and economic requirements, we should make our own interpretation of IMO standard and implementation schedule depending on our country's status. For this purpose we measured NOx emission from small and middle class marine engines to calculate emission factor and total pollutant emission in our country. With the comparison and analysis of other countries emission control regulation we proposed basic data of total emission from marine engine and future emission control standard in our country. According to our estimation, 62% of total NOx emission of marine engines comes from fishing boat and 38% from commercial vessels. The portion of NOx emission from marine engine is 18.6% of whole country NOx emission. Due to the voyage characteristics of middle and large vessel and necessity of international harmonization of marine engine pollutants emission control standard, it is inevitable to adopt IMO standard for middle and large marine engines. But considering technological and cost effect of fishing boat operating in near sea, it is resonable to set a standard within 80% of measured value at the moment and gradually implement the same IMO standard in near future.

  • PDF

A Field Survey on the Characteristics of Air Pollutants Emission from Commercial Charcoal Kiln (숯가마에서 발생하는 대기오염물질의 배출특성에 관한 현장조사 연구)

  • Park, Seong-Kyu;Choi, Sang-Jin;Kim, Jin-Yun;Park, Gun-Jin;Hwang, Ui-Hyun;Lee, Jeong-Joo;Kim, Tae-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.601-614
    • /
    • 2013
  • The commercial charcoal kiln was projected the largest source of biomass burning sector in Korea. Commercial charcoal kiln was operated to emit air pollutants into the air without any air pollution prevention equipment. The object of this field survey was to understand characteristics of air pollutants concentration and emission factors and to provide preliminary data for effective processor from oak charcoal manufacturing process. As result of field survey, TSP, $PM_{10}$ and $PM_{2.5}$ concentration from charcoal kiln were 400~37,000 $mg/m^3$. These values were over the 100 $mg/m^3$ in TSP, this value was effluent quality standard of Clean Air Conservation Act. The average concentration of CO, $SO_2$ and TVOC were 2~5%. 0~110 ppm and 820~10,000 ppm respectively. The emission factors were 42.4 g-PM/kg-oak in TSP, 40.3 g-PM/kg-oak in $PM_{10}$, 38.2 g-PM/kg-oak in $PM_{2.5}$, 182.5 g-CO/kg-oak, 1.0 g-NO/kg-oak, $SO_2$ 0.2 g-$SO_2/kg$-oak and 104.4 g-TVOC/kg-oak. The part of commercial charcoal kiln had air pollution prevention equipment but it was difficult to work properly. Much wood tar excreted in exhaust emissions from oak charcoal manufacturing process. This wood tar was cause of many troubles sticking in the air pollutant prevention equipment. For handling particulate matters and gaseous air pollutants from oak charcoal manufacturing process in biomass burning, air pollutant prevention equipment design and management needs preprocessor for removal wood tar.

Study of Smoking Booth Design for the Treatment of Hazardous Pollutants (유해오염물질 처리를 위한 흡연부스의 설계)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2017
  • The purpose of this study was to develop a Eco smoking booth that can effectively reduce hazardous pollutants generated during smoking and evaluate the efficiency and effectiveness of removing hazardous pollutants. The design and manufacture of an eco-friendly automatic smoking booth equipped with deodorizing facilities, such as inlet - HEPA filter - electrostatic precipitator (EP) - impregnated activated carbon - exhaust port, etc., and the efficiency of removing hazardous pollutants from inside and outside was measured and evaluated. The complex odor removal efficiency was 95.37% inside the smoking booth, and 97.38% at the exit of the preventive facility. The carbon monoxide removal efficiency was 94.25% in the inside and 98.32% in the outlet. In addition, the removal efficiency of particulate matter, (PM1, PM2.5, and PM10) inside the smoking booth was 98.59%, and 98.85% at the outlet. The total volatile organic compounds (TVOCs) decreased from $26,000{\mu}g/m^3$ to $5,203{\mu}g/m^3$ in the smoking booth, resulting in 79.99% removal efficiency. After the ventilator was operated, the measured effluent concentration was $5,019{\mu}g/m^3$, and the removal efficiency was 80.70%. Therefore, the smoking booth designed and manufactured through this study can be applied to the removal of harmful pollutants even in the small working environment in the future.