• 제목/요약/키워드: Exhaust gas flow control

검색결과 88건 처리시간 0.021초

2차 분사의 위치 변화에 따른 로켓노즐 출구에서의 추력 분포 변화 (The Variation of Thrust Distribution of the Rocket Nozzle Exit Plane with the Various Position of Secondary Injection)

  • 김성준;이진영;박명호
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.45-53
    • /
    • 2000
  • A numerical study is done on the thrust vector control using gaseous secondary injection in the rocket nozzle. A commercial code, PHOENICS, is used to simulate the rocket nozzle flow. A $45^{\circ}-15^{\circ}$ conical nozzle is adopted to do numerical experiments. The flow in a rocket nozzle is assumed a steady, compressible, viscous flow. The exhaust gas of the rocket motor is used as an injectant to control the thrust vector of rocket at the constant rate of secondary injection flow. The injection location which is on the wall of rocket is chosen as a primary numerical variable. Computational results say that if the injection position is too close to nozzle throat, the reflected shock occurs. On the other hand, the more mass flow rate of injection is needed to get enough side thrust when the injection position is moved too far from the throat.

  • PDF

PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구 (A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD)

  • 김효규;유지오;김두영
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.527-539
    • /
    • 2018
  • 다수의 승객들이 이용하는 지하철은 안전과 공간의 쾌적한 환경관리가 필수적이며, 2003년 이후 기준 강화로 승강장 내에 스크린도어(PSD)를 반드시 설치해야 한다. 선행연구에 따르면 지하철 화재 시에 화재연기의 배연을 위해 배연설비의 설비용량 최적설계가 필요하다. 따라서 본 연구에서는 선행연구의 실험 결과를 바탕으로 3차원 수치해석기법을 이용하여 PSD가 설치된 승강장 내에서 화재발생 시 배연시스템 별로 CO가스와 Smoke의 유동을 분석하였다. 본 연구의 결과 비상시 상부 배연설비만 가동한 경우에는 CO 가스와 Smoke 농도는 653.8 ppm과 $768.4mg/m^3$로 피난 시 승객들의 위험이 큰 것으로 분석되었으며, 모든 배연설비를 가동하고 화재측 PSD만을 개방한 경우 CO 가스와 Smoke 농도 36.0 ppm 및 $26.2mg/m^3$를 보이며 화재연기의 전파범위가 줄어드는 것으로 분석되었다. 모든 배연설비를 가동하고 화재측 PSD를 미개방한 경우에는 화재연기 유입이 발생하지 않아서 대피환경에 있어 가장 효과적인 배연모드로 분석되었다.

천연가스를 파이럿오일과 이원공급하는 직접분사식 2행정 디이젤기관의 시뮬레이션 (Simulation of Natural Gas Injected Dual-Fuel DI 2-Stroke Diesel Engine)

  • 최인수
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.9-18
    • /
    • 1995
  • The substitution of conventional fuel oil by alternative fuels is of immense interest due to liquid oil shortage and requirements of emission control standard. Among the alternative fuels, natural gas may be the most rational fuel, because of its widespread resource and clean est burning. Meanwhile, engine simulation is of great importance in engine development. Hence a zero-dimensional combustion model was developed for dual-fuel system. Natural gas was injected directly into the cylinder and small amount of distillate was used to provide the ignition kernel for natural gas burning. The intake air and exhaust gas flow was modeled by filling and emptying method. Although the single zone approach has an inherent limitation, the model showed promise as a predictive tool for engine performance. Its simulation was also made to see how the engine performance was influenced by the fuel injection timings and amount of each fuel.

  • PDF

혼합기 형성-유입과정을 고려한 천연가스엔진 모델링 연구 (A Study of on a Natural Gas Engine Modeling for Mixture formation and Intake Process)

  • 심한섭
    • 한국기계가공학회지
    • /
    • 제8권3호
    • /
    • pp.13-20
    • /
    • 2009
  • Development of a dynamic engine model is essential to predict and analyze of dynamic characteristics from a natural gas engine. Reducing the harmful exhaust emissions can be accomplished by a precise air-fuel ratio control. In this paper, the dynamic engine model was proposed and included mixture formation and intake process because the dynamic characteristics can be affected by the mixture components such as an air and a gaseous fuel. The air mass flow, the partial pressure ratio, and the gas constant are changed by variations of the components in the mixture formation and intake process. The dynamic engine model is applied to the natural gas engine for validation test. Experimental results show that the dynamic engine model is effective to predict the dynamic characteristics of the natural gas engine.

  • PDF

빌딩주변 자동차 배기가스중의 NOx 분산에 관한 수치해석 (Numerical Simulation on Dispersion of NOx in Vehicular Exhaust Gas around Buildings)

  • 전영남;정오진;송형운
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.655-660
    • /
    • 2004
  • This paper demonstrates the numerical simulation of three dimensional flow pattern for vehicular exhaust dispersion in the street canyons. The wind flow around buildings in urban is computed by the SIMPLEST method. The convection-diffusion equation was used to compute the $NO_X$ concentration level near buildings. Details are given of important boundary conditions and turbulence quantities variations. The simple turbulence model was used for unisotropic viscous effect. A control-volume based finite-difference method with the upwind scheme is employed for discretization equation. The simple turbulence model applied in this study has been verified through comparison between predicted and measured data near buildings. By the predictive results, the updraft induced by the presence of high-rise buildings is important in the transport of street level pollutant out from the street canyons. Our suggestion for reducing ground level pollution is to have high-rise buildings constructed or to reduce the channelling effect of street canyons.

기체연료엔진의 제어시스템 설계를 위한 엔진 모델링 및 검증 (Engine Modeling and Validation for Control System Design of a Gaseous-fuel Engine)

  • 심한섭;선우명호
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.7-17
    • /
    • 2003
  • Highly accurate control of an air-fuel ratio is very important to reduce exhaust gas emissions of gaseous-fuel engines. In order to achieve this purpose, a precise engine model is required to estimate engine performance from the engine design process which is applied to the design of an engine controller. Engine dynamics are considered to develop a dynamic engine model of a gaseous-fuel engine. An effective air mass ratio is proposed to study variations of the engine dynamics according to the water vapor and the gaseous-fuel in the mixture. The dynamic engine model is validated with the LPG engine under steady and transient operating conditions. The experimental results in the LPG gaseous-fuel engine show that the estimation of the air flow and the air-fuel ratio based upon the effective air mass ratio is more accurate than that of a normal engine model.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

원통형 고체산화물 연료전지와 마이크로 가스터빈 하이브리드 시스템의 성능해석을 위한 모델링 (Modeling for the Performance Analysis of a Tubular SOFC/MGT Hybrid Power System)

  • 송태원;손정락;김재환;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2070-2075
    • /
    • 2004
  • Performance of a solid oxide fuel cell (SOFC) can be enhanced by converting thermal energy of its high temperature exhaust gas to mechanical power using a micro gas turbine (MGT). A MGT plays also an important role to pressurize and warm up inlet gas streams of the SOFC. In this study, the influence of performance characteristics of the tubular SOFC on the hybrid power system is discussed. For this purpose, detailed heat and mass transfer with reforming and electrochemical reactions in the SOFC are mathematically modeled, and their results are reflected to the performance analysis. The analysis target is 220kWe SOFC/MGT hybrid system based on the tubular SOFC developed by Siemens-Westinghouse. Special attention is paid to the ohmic losses in the tubular SOFC counting not only current flow in radial direction, but also current flow in circumferential direction through the anode and cathode.

  • PDF

기계적 편향판 설치위치의 변화에 따른 유동특성에 대한 연구 (A Study on Flow Characteristics with the Installed Location Change of Mechanical Deflector)

  • 김경련;박종호
    • 한국유체기계학회 논문집
    • /
    • 제18권5호
    • /
    • pp.49-53
    • /
    • 2015
  • Thrust vector control is the method which generates the side force and roll moment by controlling exhausted gas directly in a rocket nozzle. TVC is classified by mechanical and fluid dynamic methods. Mechanical methods can change the flow direction by several objects installed in a rocket nozzle exhaust such as tapered ramp tabs and jet vane. Fluid dynamic methods control the flight direction with the injection of secondary gaseous flows into the rocket nozzle. The tapered ramp tabs of mechanical methods are used in this paper. They installed at the rear in the rocket nozzle could be freely moved along axial and radial direction on the mounting ring to provide the mass flow rate which is injected from the rocket nozzle. TVC of the tapered ramp tabs has the potential to produce both large axial thrust and high lateral force. We have conducted the experimental research and flow analysis of ramp tabs to show the performance and the structural integrity of the TVC. The experiments are carried out with the supersonic cold flow system and the schlieren graph. This paper provides to analyze the location of normal shock wave and distribution of surface pressure on the region enclosed by the tapered ramp tabs.

Performance of a Biofilter for Odor Removal during Manure Composting

  • Park, K.J.;Hong, J.H.;Choi, M.H.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.59-64
    • /
    • 2002
  • Odor generated during composting of livestock manure is mainly due to ammonia emission. Biofiltration is a desirable method to control composting odor. This study was conducted to analyze the efficiency of using fresh compost as a biofilter. A mixture of cattle manure and recycled compost was composted in a bin equipped with a suction-type blower. The exhaust gas was filtered through the fresh compost. Residence time was controlled by the flow rate of exhaust gas and the depth of filtering materials. At the aeration rate of 30 L/min(experiment I), ammonia reduction rate varied from 100% to -15% for biofilter A(residence time 56.5 s) and almost 100% for biofilter B(residence time 113 s). At the aeration rate of 30 L/min, the cumulative ammonia reduction rate was 80.5% for biofilter A and 99.9% for biofilter B. At the aeration rate of 50 L/min(experiment II), the lowest reduction rate showed a negative value of -350% on the 8th and 9th day for biofilter A(residence time 33.9 5), and 50% on the loth day for biofilter B(residence time 67.8s). At the aeration rate of 50 L/min, the cumulative ammonia reduction rate was 82.5% fur biofilter A and 97.4% for biofilter B. Filtering efficiency was influenced by residence time. The moisture content(MC) and total nitrogen(T-N) of the filtering material were increased by absorbing moisture and ammonia included in the exhaust gas, while pH was decreased and total carbon(T-C) remained unchanged during the filtering operation.

  • PDF