도로터널 화재시 반횡류식 균일배기 환기방식에서의 최적배연 연구 (A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation)

  • 전용한;유지오;김남진;서태범;김종윤
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.186-192
    • /
    • 2009
  • In this study it is intended to review the moving characteristics of smoke by performing visualization for calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for design of the smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. In case of oversized exhaust ports, the generated smoke is more than the case of uniform exhaust. When the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173\;m^3/s$, $236\;m^3/s$ for the distance of the moving smoke which can limit the distance to 250 m.

중.소규모 사업장의 국소배기장치 설치 실태와 문제점 및 개선방안 (Additional Improvement and Evaluation of Exhaust Ventilation Systems at Small and Medium Sized Enterprise)

  • 임성근;박두용;김원기;김수근
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2010
  • Objectives : The purposes of this study were to evaluate exhaust ventilation systems(EVSs) and to suggest problems and improvements. Methods : For 50 small and medium-sized enterprises, we carried out evaluation of EVSs. We evaluated hoods with smoke tester and measurement of capture velocity. In addition, we used several indicators for performance evaluation designed in this study. Results : 1. Based on the smoke flow pattern and the criteria of occupational health and safety act, 67.8% of hoods were rated 'good' level at smoke test whereas 26.3% were rated 'good' level at measurement of capture velocity. 2. 29.3% of hoods, of which ratio of measured actual air flow at hood(Qah) to required ideal exhaust air flow at hood(Qih) was 1 or more, were rated 'good' level. 3. The % of EVS, of which ratio of measured actual air flow at stack(Qast) to total required ideal exhaust air flow at hood(Qith) was 1 or more, was 29.0%. 4. For the ratio of measured Qast to existing air flow at fan(Qfan), only 5% of EVSs were 1 or more and 26.0% were 0.8 or more but less than 1.0. 5. For the ratio of measured Qast to total measured actual exhaust air flow at hood(Qath), 74.0% were 0.8 or more but less than 1.0. 6. The percentage of EVS, of which ratio of total measured Qath to existing Qfan was 0.8 or more, was 19.0%. 7. The percentage of EVS, of which ratio of total measured Qath to total required ideal exhaust Qith was 1 or more, was 26.0%. 8. For the comprehensive evaluation indicators designed in this study, 29.0% were 0.8 or more. Conclusions : We found that few exhaust local ventilations at small and medium-sized enterprises were rated 'good' level and that most exhaust local ventilations had 'poor' design and installation. Therefore, relevant professional manpower and enterprises have to construct exhaust local ventilation where it is needed, and technical guidance and economic support are needed to improve 'poor' exhaust local ventilation after self-evaluation.

공동주택 화장실의 급기구 및 배기팬 설치위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Various Location of Air Intake and Exhaust Fan of Bathroom in Apartment Housing)

  • 함진식;이광명
    • 한국주거학회논문집
    • /
    • 제15권5호
    • /
    • pp.77-84
    • /
    • 2004
  • The mock-ups of ventilation system, which has been widely adopted for the bathroom with the area of 100 $m^2$ apartment housing, were established and tested to design mechanical ventilation for apartment housing bathroom where air supply exhaust are relatively important. These ventilation mock-ups were capable of controlling intake and exhaust, which has the size of supply openings as 40cm${\times}$1cm, 40cm${\times}$3cm, 40cm${\times}$5cm. They were established at five locations, spaced 40cm from each other at a height of 25cm from the floor. The exhaust fans were located at four corners and center of the ceiling. The results this ventilation effect measurement by different condition are showing that when the size of air supply is bigger and the location is lower, the effect of ventilation was relatively higher. In addition, as the distance between exhaust fan and air supply was farther, the ventilation effect were getting highly efficient.

변풍량 공조시스템의 요구외기량 확보를 위한 제어방식 (Control Methods of the VAV Air Handling Unit for the Required Outdoor Air Demand)

  • 한도영;주영덕;김진;이준호
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.203-209
    • /
    • 2003
  • Control algorithms of an air handling unit by using the mixing box plenum pressures were developed and verified by experiments. Control algorithms developed for this study were the setpoint algorithms for the outdoor damper position, the outdoor/fixed plenum pressure, and the return/exhaust plenum pressure. The outdoor/fixed plenum pressure setpoint was used to control the bypass damper position, and the return/exhaust plenum pressure setpoint was used to control the return fan speed. Experimental results showed the good control of the required outdoor air demand. Therefore, setpoint algorithms developed for this study may effectively be applied for the control of the VAV air handling unit.

T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석 (Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method)

  • 문종선;강석윤;이승철;유호선;이재헌
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.

배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究) (A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas)

  • 최영돈;박상동;우정선;태춘섭
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

역유동계산법을 이용한 국소배기효율의 수치해석 (Numerical analysis of local exhaust effectiveness using reverse-flow calculation method)

  • 한화택
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.658-665
    • /
    • 1998
  • This paper investigates local exhaust effectiveness in a room with a supply and an exhaust slots on the ceiling. The mean age of air is an indicator of supply effectiveness, while the mean residual life time can be used as an indicator of exhaust effectiveness. The distribution of local mean residual life time in a space is calculated by four different numerical procedures. The reverse-flow calculation method has been proved to show quite accurate results while it can save considerable amount of computation time and efforts, compared to the method by its original definition. It is concluded that the diffusion term in the equation of mean residual life time can be neglected. The spatial and temporal diffusion characteristics of the contaminant are also discussed.

  • PDF

직접 분사식 소형 과급 디젤엔진의 운전조건이 배기 배출물에 미치는 영향 (An Effect of Operating Conditions on Exhaust Emissions in a Small Turbocharged D.I. Engine)

  • 장세호;고대권;안수길
    • 동력기계공학회지
    • /
    • 제6권2호
    • /
    • pp.12-17
    • /
    • 2002
  • Recently, the world is faced with very serious problems related to the air pollution due to the exhaust emissions of the diesel engine. So, many of researchers have studied to reduce the exhaust emissions of diesel engine. This study was investigated for various exhaust emissions according to operating conditions in a turbocharged D.I. diesel engine. As a result of experiments in a test engine, the $CO_2\;and\;NO_x$ increased with increasing load, the $CO_2$ and CO decreased with increasing charge air pressure in manifold, the CO decreased with increasing cooling fresh water temperature, and the $NO_x$ decreased with worming cooling fresh water before engine start.

  • PDF

중속 디젤기관의 질소산화물 배출특성에 관한 연구 (A Study on the Emission Characteristics of NOx in Medium Speed Diesel Engine)

  • 우석근;윤건식;윤영환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.526-534
    • /
    • 2000
  • In this study, the characteristics of exhaust emissions in medium speed diesel engine under various operating conditions were investigated through experiments to derive the optimum conditions for minimizing the exhaust emissions, especially, nitrogen oxides. The 355 KW$\times$1200 rpm medium speed diesel engine was intensively examined to investigate the trend of exhaust emissions in case that the parameters affecting combustion conditions such as fuel injection timing, intake air temperature and pressure, engine speed and load were changed. The exhaust emissions for 9 sets of medium speed diesel engine were analyzed in addition. From this study, NOx level could be reduced by 30~50% through the adjustment of retarded fuel injection timing, lowered intake air temperature and increased charging air pressure.

  • PDF

인명안전 관점에서 선박 화재 시 급·배기조건에 따른 배연성능 예측평가 (Smoke Exhaust Performance Prediction According to Air Supply and Exhaust Conditions for Shipboard Fires from a Human Safety Point of View)

  • 김별;황광일
    • 해양환경안전학회지
    • /
    • 제22권7호
    • /
    • pp.782-790
    • /
    • 2016
  • 선박의 기계식 환기시스템은 화재발생 시 연기의 생성과 확산 특성에 영향을 미치고, 이는 피난자의 피난경로 상의 가시도를 방해함으로써 피난자의 연기로 인한 피해를 증가시킬 위험성이 크다. 이에 이 연구에서는 선박 거주구역에서 화재발생 시 기계식 급 배기시스템이 연기확산에 미치는 영향과 위험성에 대하여 FDS를 활용하여 평가하고 화재 시 급 배기시스템을 효율적으로 사용할 수 있는 방안을 제안하였다. 연구결과 화재가 발생한 장소에 급 배기시스템이 함께 작동되고 있는 경우에는 현재 권장되고 있는 급 배기시스템을 멈추는 방법보다 작동을 유지하는 것이 효과적이고, 배기시스템만 작동되는 곳에서 화재가 발생한 경우에는 화재가 발생한 구역 이외의 구역에서 급기시스템을 함께 작동시키는 것이 피난시간을 확보하는데 효과적인 것으로 예측되었다. 그러나 화재가 발생한 곳에 급기시스템만 있는 경우에는 급기시스템이 연기확산을 가속시키기 때문에 급기방식을 중단시켜 연기의 확산을 최대한 억제할 필요가 있음을 확인하였다.