• Title/Summary/Keyword: Excitation test

Search Result 552, Processing Time 0.026 seconds

A Method on Safety Assessment of Shell-type Roller Gate (쉘타입 로울러게이트의 안전성평가 방법)

  • Chung, Jee-Seung;Jung, Hae-Wook;Lim, Hyung-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.92-98
    • /
    • 2015
  • This paper was carried out to prove the relation between static loads acting on the sluice(hydrostatic) and dynamic loads (additional loads) arising from opening or closing of sluice, through measuring the operation of shell-type roller gate by using the method of measuring of the completely opening water gate, as measured from one excitation state, it was confirmed to be capable of measuring the natural frequency reliable measurement results. Throughout the test, we prove that it's a reasonable way to estimate the default margin of safety when calculated by dividing the sum of the hydrostatic stress to the maximum stress and additional stress. The application of this paper's safety estimation method can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

Bending Motion Control of Electroactive Polymer Actuator-Sensor Hybrid Structure for Finger Exoskeleton (손가락 외골격용 전기활성 고분자 구동체-센서 하이브리드 구조체의 굽힘 동작 제어)

  • Han, Dong Gyun;Song, Dae Seok;Jho, Jae Young;Kim, Dong Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.865-871
    • /
    • 2015
  • This study was conducted in order to develop a finger exoskeleton system using ionic polymer metal composites (IPMCs) as the actuator and sensor in a hybrid structure. To use the IPMC as an actuator producing large force, a first order transfer function was obtained using results from a block force for DC excitation that applied to two IPMCs of 20mm-width, 50mm-length, and 2.4mm thickness together. After which the validation of 200gf control with anti-windup PI controller was confirmed. A 5mm-width, 50mm-length, 0.6mm-thickness of IPMC was also modeled as a sensor for tip displacement. As a result, the IPMC sensor could been utilized as a trigger role for the actuator. Finally, an IPMC sensor and actuator were installed on the joint of a single DOF exoskeleton in the hybrid structure, and test for the control of 40gf of block force and predefined sequence of motion was performed.

Time Delay Focusing of Ultrasonic Array Transducers on a Defect Using the Concept of a Time Reversal Process

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Lee, Chung-Hoon;Jun, Ghi-Chan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.550-556
    • /
    • 2009
  • In an application of a time reversal(TR) focusing of array transducer on a defect inside the test material, we employ a new time delay focusing technique based the TR process. In order to realize this idea, a multi-channel ultrasonic system is constructed capable of applying necessary time delays to each channel. The TR-based focusing procedure first measures the backscattered signals after firing one of the array elements. A phase slope method is then used to determine the time-of-flights of the backscattered signals received by all elements of the array. These time delays are used to adjust the time of excitation of the elements for transmission focusing on the defect. In addition to the TR focusing, the classical phased array focusing is also considered for comparison. Experimental results show that the TR-based time delay focusing produces much stronger backscattered signals than the phased array focusing, demonstrating the enhanced capability of the TR focusing.

Disturbance State Identification of Power Transformer Based on Dempster's Rule of Combination (Dempster 결합룰에 의한 전력용 변압기 외란상태판정)

  • Kang, Sang-Hee;Lee, Seung-Jae;Kwon, Tae-Won;Kim, Sang-Tae;Kang, Yong-Cheol;Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1479-1485
    • /
    • 1999
  • This paper proposes a fuzzy decision making method for power transformer protection to identify an internal fault from other transient states such as inrush, over-excitation and an external fault with current transformer (CT) saturation. In this paper, analyzing over 300 EMTP simulations of disturbances, four input variables are selected and fuzzified. At every sampling interval from half to one cycle after a disturbance, from the EMPT simulations, different fuzzy rule base is composed of twelve if-then fuzzy rules associated with their basic probability assignments for singleton- or compound-support hypotheses. Dempster's rule of combination is used to process the fuzzy rules and get the final decision. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 12(ms). The proposed method is implemented into a Digital Signal Processor (TMS320C31) and tested.

  • PDF

The Characteristics of High Voltage Output Flux Pump for Superconducting Magnet (초전도 마그네트용 고출력 플럭스 펌프의 특성)

  • Choi, Kyeong-Dal;Hahn, Song-Yop;Tsukiji, Hiroshi;Hoshino, Tsutomu;Muta, Itsuya
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.86-88
    • /
    • 1996
  • Using superconducting magnetic flux pump, thick power leads for a superconducting magnet could be replaced with thin string leads for the excitation magnet to the superconducting flux pump. We have developed a new type flux pump with high voltage output to shorten the charge and discharge time of the load magnet. The test of four stacked disks as the excither for the load magnet has been carried out. This disk type flux pump yielded 70 mV of voltage across its terminal and 10 A of current through 85 mH load magnet which was the field winding of 20 kVA class fully superconducting generator within 12 seconds. This output voltage of the new superconducting flux pump is about 10 times larger than that of the previous work Moreover since it is easy to stack the disks for the superconduction flux pump, the high voltage exciter for the 1H class superconducting magnet would be expected to be made easily.

  • PDF

Sensorless vector control for super-high speed PMSM drive

  • Bae Bon-Ho;Sul Seung-Ki;Kwon Jeong-Hyeck;Shin Jong-Sub
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.773-778
    • /
    • 2001
  • This paper describes the implementation of the vector control schemes for a variable-speed 131kW PMSM (Permanent Magnet Synchronous Motor) in super-high speed application. The vector control with synchronous reference frame current regulator has been implemented with the challenging requirements such as the extremely low stator inductance$(28^{\mu}H)$, the high dc link voltage(600V) and the high excitation frequency(1.2kHz). Because the conventional position sensor is not reliable in super-high speed, a vector control scheme without any position sensor has been proposed. The proposed sensorless algorithm is implemented by processing the output voltage of the PI current regulator, and hence the structure is simple and the estimated speed is robust to the measurement noise. The experimental system has been built and the proposed control has been implemented and evaluated. The test result, up to the speed of 60,000 r/min, shows the validity of the proposed control.

  • PDF

Operational Vibration Experiment and Analysis of a Small Vertical-Axis Wind Turbine Considering the Effect of a Tower Stiffness (타워강성 효과를 고려한 소형 수직축 풍력발전기 운전 진동실험 및 해석)

  • Choo, Heon-Ho;Sim, Jae-Park;Oh, Min-Woo;Kim, Dong-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.3
    • /
    • pp.5-9
    • /
    • 2013
  • In this study, operational vibration experiment and analysis have been conducted for the 4-blade small vertical-axis wind turbine (VAWT) including the effect of tower elastic behavior. Computational structural dynamics analysis method is applied to obtain Campbell diagram for the VAWT with elastic tower. An open type wind-tunnel is used to change and keep the wind velocity during the ground test. Equivalent elastic tower is used to support the VAWT so that the effect of elastic stiffness of the tower can be considered in the present vibration experiment. Various excitation conditions with wind loads are considered and the dominant operating vibration phenomena are physically investigated in detail.

Design of a Bimorph Piezoelectric Energy Harvester for Railway Monitoring

  • Li, Jingcheng;Jang, Shinae;Tang, Jiong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.661-668
    • /
    • 2012
  • Wireless sensor network is one of prospective methods for railway monitoring due to the long-term operation and low-maintenance performances. How to supply power to the wireless sensor nodes has drawn much attention recently. In railway monitoring, the idea of converting ambient vibration energy from vibration of railway track induced by passing trains to electric energy has made it a potential way for powering the wireless sensor nodes. In this paper, a bimorph cantilever piezoelectric energy harvester was designed based on a single degree-of-freedom model. Experimental test was also performed to validate the design. The first natural frequency of the bimorph piezoelectric energy harvester was decreased from 117.1 Hz to 65.2 Hz by adding 4 gram tip mass to the free end of the 8.6 gram energy harvester. In addition, the power generation of the piezoelectric energy harvester with 4 gram tip mass at resonant frequency was increased from 0.14 mW to 0.74 mW from $2.06m/s^2$ base excitation compared to stand-alone piezoelectric energy harvester without tip mass.

The Development of Evaluation Process for Dynamic Characteristics of Door Module (자동차용 모듈화 도어의 동특성 평가 시험법 개발)

  • Bae, Chul-Yong;Kim, Chan-Jung;Kwon, Seong-Jin;Lee, Bong-Hyun;Jang, Woon-Sung;Lee, Joon-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.291-296
    • /
    • 2007
  • This study presents the evaluation process for door module. Its objective evades the resonance generated at module plate due to the operation of window regulator motor. For this study, the design improvement process is composed of experimental methods having three steps. First step is modal analysis at door assembly status for acquisition of dynamic characteristics which are modal frequency and damping. Second step is a vibration experiment to get the test mode considered an efficiency of window regulator motor. Last step is a vibration measurement by the form of $6{\times}6$ array on module plate. A vibration measurement of 6x6 array form can be got to three analysis results which are a transfer path of vibration using cross correlation function, a vibration map using OA level and a contribution by frequency band using coherent output power spectrum on module plate. These results are applied to SDM(structural dynamic modification) for design improvement to get around the resonance on module plate by the excitation of window regulator motor.

  • PDF

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.