• Title/Summary/Keyword: Excessive Vibration

Search Result 313, Processing Time 0.031 seconds

Study on Reduction of Excessive Noise and Vibration of Aft Part of High Speed Ro-Ro Passenger Ship (고속 여객선 선미부 과대 진동/소음 감소를 위한 연구)

  • Shin, Yunkil
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.196-202
    • /
    • 2019
  • In this study, the excessive noise and vibration phenomena of a high-speed Ro/Ro passenger ship were analyzed, and a countermeasure was taken based on them. This ship was granted a comfort class notation by the classification society, which was COMFORT-VIBRATION-II and COMFORT-NOISE-CREW-II. However, unfortunately, excessive noise and vibration in the aft part of the ship were delivered from the twin shaft propellers, and therefore the Class Requirement was not satisfied before delivery. In order to obtain the class notation, all of the concerned parties came to an agreement to reduce the noise and vibration level during operation after delivery because a seasonal ferry service was already scheduled and the cabin was fully booked. The root cause of the massive amount of noise and vibration was mainly the propeller-induced excitation pulse and beating that occurred from the mismatch of the rotating speeds of the two shaft lines. A 1st order vibrating force and beating phenomena existed in the propeller. Thus, a reduction of the excitation force, elimination of the beating phenomena, and decrease of the noise level at the aft area cabins and public spaces were required. In addition, structural reinforcements were conducted using pillars and additional girders at the aft part of the decks.

Analysis on the Excessive Vibration of the KTX Tail Cars (KTX 후미차량의 과다 진동해석)

  • Chang Jong-Ki;Lee Seung-Il;Choi Yeon-Sun
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.740-746
    • /
    • 2003
  • In winter season the driving test of the KTX showed the excessive vibration in the tail cars. In this paper, the measured KTX vibration data during test run is analyzed in time and frequency domain. And the numerical simulations using ANSYS and ADAMS are done on the basis of the experimental observations. The results show that 0.6Hz of the tail car motion is due to the natural mode of car combination of the KTX.

  • PDF

Use of High Order Vibration Modes for Design of Piezo Energy Harvester (압전 발전기의 설계를 위한 고차 모드의 활용)

  • Hwang, Woo-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.4
    • /
    • pp.372-376
    • /
    • 2012
  • The most common type of the piezoelectric energy harvester is the cantilevered beam since it is attached to the host structure and tuned to the frequency of the base excitation easily. However, the excessive strain at the fixed end of cantilevered beam causes some problems such as fatigue and durability. The use of higher vibration modes of the cantilevered beam may reduce the concentration of the strain at the fixed end since the strains of higher modes are distributed along the span. The results show that the use of high vibration mode is not efficient for power generation, but it reduces the excessive strain lever at typical region to prevent the failure by fatigue.

A Study on Vibration and Noise Reduction of a Lathe Gear Box (선반 기어박스의 진동.소음 분석과 저감에 관한 연구)

  • 박선균;최영휴;배병태;정택수;김청수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.552-558
    • /
    • 2001
  • When operating lathe gear box which is equipped with geared transmission, it sometimes generates loud noise and excessive vibrations. In order to identify their causes, in this study, torsional and lateral vibration characteristics including critical speeds of the gear transmission system are firstly analyzed using lumped parameter models. Natural frequencies and mode shapes of the gear box structure are also analyzed by using the modal test. Furthermore, measured vibration and noise signals during operations are analyzed and compared with theoretical analysis results. After all, it is concluded that the primary cause of the excessive noise and vibrations is the resonance between gear meshing frequency including its side bands, the frequencies of shaft bending and torsional vibrations, and the natural frequencies of the gear box structure. Consequently the noise and vibration levels are greatly reduced by avoiding resonance between the natural frequencies and gear meshing frequencies through the rearrangement of the gears on the transmission shaft without any gear ratio change.

  • PDF

Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant (정수장용 교반기 시설의 과진동 원인 분석)

  • Park, Jinho;Lee, Jeong-Han;Kim, Bong-Soo;Kang, Mun-Hu;Kim, Dong-Soo;Joo, Yoon-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.336.1-336
    • /
    • 2002
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. The cause of an excessive vibration of a base structure to which the mixers are supported, has been evaluated through modal analysis on the mixer shaft and vibration measurements during operation. The fundamental natural frequency of the mixer shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. (omitted)

  • PDF

Vibration Analysis of Building Floor Subjected to Walking Loads (보행하중을 받는 건축물 바닥판의 진동해석)

  • 김기철;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.414-421
    • /
    • 2001
  • Recently, the damping effect of building structures are greatly reduced because the use of non-structures members as like curtain wall are decreased and large open space are in need for the service of buildings. Assembly and office buildings with a lower natural frequency have a higher possibility of experiencing excessive vibration induced by human activities as like jumping, running and walking. These excessive vibration make the occupants uncomfortable and the serviceability deterioration. The common method of application of walking loads for the vibration analysis of structures subjected to walking loads is to inflict a series unit walking load and a periodic function at a node. But this method could not consider the moving effect of walking. In this study, natural frequency and damping ratio of plate structure are evaluated by heel drop tests. And new application of equivalent walking loads are introduced for vibration analysis of real slab system subjected to walking loads. The response obtained from the numerical analysis are compared well to the results measured by experimental tests. It is possible to efficiently analyze the vibration of floor which is subjected to walking loads by applying equivalent walking loads.

  • PDF

Performance Evaluation of a Nonlinear Cable Damper for Stay Cables Using Wind Vibration Analysis (사장교 케이블의 풍진동 해석을 통한 비선형 댐퍼의 성능 검증)

  • Kim, Saang-Bum;Lee, Sung-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.603-606
    • /
    • 2007
  • Wind induced vibration of a stay cable with a nonlinear friction damper is investigated. Stay cables are likely to vibrate under several wind-related environments, and cable dampers can be used to suppress the excessive vibrations of stay cables. Conventional design of cable dampers are based on the equivalent modal damping achieved by the cable damper. However, the equivalent modal damping achieved by nonlinear dampers are depend on the vibration characteristics like the amplitude of the vibration. In this paper, not only the achieved equivalent modal damping, but also the vibration levels under gust wind are analyzed through the time domain buffeting analysis. Numerical simulation results show the efficacy of a nonlinear friction damper for suppressing the excessive vibration of a stay cable.

  • PDF

A Study on the Solution of Excessive Accelerations on the Bridge for Gyeongbu High-speed Railway (경부고속철도 교량의 과도한 가속도의 저감방안에 대한 연구)

  • Kwark, Jong-Won;Chin, Won-Jong;Choi, Eun-Suk;Cho, Jeong-Rae;Lee, Jung-Woo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.477-485
    • /
    • 2007
  • When Korean High Speed Train (KTX) runs over a high-speed railway bridge, the high-speed railway bridge gives quite large acceleration response. Local vibration at the large cross section, the impact from equally spaced sleepers, the vibration due to elastomeric bearings, and the vibration from the train itself are the causes of this acceleration response. Maximum peaks of the accelerations measured at the bridges are sometimes going over the limit value. Although it is smaller than 0.35G, the limit from the Korean Bridge Design Manual(BRDM), this acceleration response should be reduced for the safety of running trains with high speed. In this paper, to reduce the acceleration response by controlling excessive local vibration at the large cross section, vibration reduction method is studied. The result shows that the effect of elastomeric bearings on the vibration of the bridge is very large and that the vibration reduction device is effective against wing mode local vibration PSC box girder bridge for the high-speed railway, which usually has very large cross section, although it has little effect on global vibration modes such as flexural and twisting modes. The test of the vibration reduction device on the bridge in service has been performed in this study.

  • PDF

Analytical and Experimental Study on Vibration Characteristics for Rectangular Tank Structure Filled with Fluid (사각헝 탱크 구조의 접수 진동 특성에 관한 연구)

  • 최수현;김극수;손성완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.195-203
    • /
    • 2002
  • In the engine room and the aft part areas of the ship, there exist so many tank structures contacting with fresh water or sea water or oil. If these structures exhibit excessive vibrations during the sea trials, it takes a lot of cost, time and effort to improve vibration situation because the reinforcement work requires emptying the fluid out of the tanks, additional welding and special painting. It is therefore very important to predict a precise vibration characteristics of the tank structures at the design stage, however it is not easy to estimate vibration characteristics of the structures because of difficulties for accurate evaluation of the added (or virtual) mass effect due to the fluid inside the tank. In this paper, numerical and experimental approaches have been performed to present same fundamental data necessary for anti-vibration design of tank structures contacting with fluid, by investigating vibration behaviors of rectangular tank structure for various water depths.

Random Vibration Analysis for Satellite Design (위성체 설계를 위한 랜덤 진동 해석)

  • Lee, Won-Beom;Kim, Gyeong-Won
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.102-107
    • /
    • 2006
  • In this study, the dynamic environment of satellite consists of excessive vibration at low frequency and irregular acceleration transferred by launch vehicle structure. Excessive vibration at low frequency is generally approximated by a sinusoidal wave from 100Hz to 200Hz and primarily used to preliminary design The random vibration is created by structural vibration due to the combustion of launch vehicle, separation stage and external aerodynamic noise. these are transferred to the adapter structure between satellite and launch vehicle through the structure of launch vehicle. random vibration is being specified for acceptance tests, screening tests, and qualification tests, because it has been shown that random vibration more closely represents the true environments in which the electronic equipment must operate.

  • PDF