• Title/Summary/Keyword: Excesses

Search Result 64, Processing Time 0.023 seconds

A study on the applicability of system for monitoring the flood level and the scour at railroad bridge (철도교량 홍수위감시 및 세굴검지 시스템 적용성 고찰)

  • Park Young Kon;Lee Jin Wook;Yoon Hee Taek;Kim Seon Jong
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.530-535
    • /
    • 2005
  • To monitor the flood level under heavy rainfall and the scour at railroad bridge, the system, which can effectively collect, store and transmit the data, is developed and applied to the field. The results in this study are as follows. 1) Monitoring for water level and scour depth is well done in view of the recording velocity and the accuracy of data which are measured. 2) This system is based on the web, internet and it is able to collect the realtime data and to analyze the risk. 3) When water level excesses the limit of danger level of a river on which railroad bridge is located, or when scour depth and angle of inclination of pier is increased, the scenario for early warning signal which sends to managers at central traffic control and drivers of trains is automatically made. It is judged that this system secures the safety of railroad and protects lives of train passengers as the warning signal sends to running train in advance at risky situation of railroad bridge under heavy rainfall.

  • PDF

Research on Transmission Line Design for Efficient RF Power Delivery to Plasma (전송선로를 이용한 플라즈마 전력 전달 연구)

  • Park, In Yong;Lee, Jang Jae;Kim, Si-Jun;Lee, Ba Da;Kim, Kwang Ki;Yeom, Hee Jung;You, Shin Jae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.6-10
    • /
    • 2016
  • In RF plasma processing, when the plasma is generated, there is the difference of impedance between RF generator and plasma source. Its difference is normally reduced by using the matcher and the RF power is transferred efficiently from the power generator to the plasma source. The generated plasma has source impedance that it can be changed during processing by pressure, frequency, density and so on. If the range of source impedance excesses the matching range of the matcher, it cannot match all value of the impedance. In this research, we studied the elevation mechanism of the RF power delivery efficiency between RF generator to the plasma source by using the transmission line and impedance tuning of the plasma source. We focus on two plasma sources (capacitive coupled plasma (CCP), inductive coupled plasma (ICP)) which is most widely used in industry recently.

Evaluation Efficiency of University libraries though Data Envelopment Analysis (DEA를 이용한 대학도서관의 효율성 평가 -프랑스의 대학도서관을 대상으로-)

  • Kim, Sun-Ae
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.38 no.2
    • /
    • pp.137-160
    • /
    • 2004
  • In order to appreciate the varied activities of university libraries, this study assesses their efficiencies in the process of production and utilization of their services for two consecutive years, 1999 and 2000. Using a Data Envelopment Analysis with exogenously fixed factors, this study analyses separately efficiencies identified. The results show that efficiencies of libraries appear differently according to the year of evaluation, the dimension of evaluation as well as the difference of statute. The specialized libraries as CADIST are definitely higher in terms of use of services. In addition, inefficiency is mainly due to deficits of production of outputs rather than excesses of utilisation of inputs. For example, time devoted to user's training constitutes the most significant potentiality of increase in the production of services.

The Effect of Reducing Agent on the Production of Niobium Powder by Metallothermic Reduction (금속열환원법에 의한 니오븀 분말제조시 환원제의 영향)

  • Hwang, Sun-Ho;Yoon, Jae-Sik;Kim, Byung-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.4
    • /
    • pp.186-189
    • /
    • 2009
  • In this study, niobium powder was made from potassium heptafluoroniobite($K_2NbF_7$) using sodium(Na) as a reductant and KCl, KF as a diluent based on the hunter metallothermic reduction method. The excesses of reductant were varied from 0%, 3%, 5% and 7%. When 7% excess of sodium was used, the un-reacted sodium remained in the reacted product. The niobium powder has been achieved by reducing 50 g of $K_2NbF_7$ with 5% sodium excess in a charge at a reduction temperature of $850^{\circ}C$. The proportion of fine fraction decreased appreciably and the yield of niobium powder improved from 65% to 85% with the increase of sodium excess. The average particle size of niobium powder is improved from 0.2 microns to 0.3 microns in the 5% excess sodium.

Polymer Adsorption at the Oil-Water Interface

  • Lee, Woong-Ki;Pak, Hyung-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.5
    • /
    • pp.398-403
    • /
    • 1987
  • A general theory of polymer adsorption at a semi-permeable oil-water interface of the biphasic solution is presented. The configurational factor of the solution in the presence of the semi-open boundary at the interface is evaluated by the quasicrystalline lattice model. The present theory gives the feature of the bulk concentration equilibria between oil-water subsystems and the surface excesses of ${\Gamma}^{\alpha}$ and ${\Gamma}^\{beta}$ of the polymer segments as a function of the degree of polymerization $\gamma$, the Flory-Huggins parameter in $\beta$-phase $x_{\rho}^{{\beta}_{\rho}}$, the differential adsorption energy parameter in $\beta$-phase $x_{\sigma}^{{\beta}_{\rho}}$, the differential interaction energy parameter ${\Delta}x_{\rho}$ and the bulk concentration of the polymer in ${\beta}-phase ${\varphi}_2^{{\beta(*)}_2}$. From our numerical results, the characteristics of ${\Gamma}^{\alpha}$ are shown to be significantly different from those of ${\Gamma}^{\beta}$ in the case of high polymers, and this would be the most apparent feature of the adsorption behavior of the polymer at a semi-permeable oil-water interface, which is sensitively dependent on ${\Delta}x_{\rho}$ and r.

Thermal Stresses of Roller Compacted Concrete Dam Considering Construction Sequence and Seasonal Temperature (시공단계 및 계절별 온도영향을 고려한 롤러다짐콘크리트댐의 온도응력 해석)

  • Cha, Soo-Won;Jang, Bong-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.881-891
    • /
    • 2008
  • The purpose of the present study is to investigate the influence of seasonal temperature variation on the thermal stresses in roller compacted concrete dam(RCD) structures. Using the finite element code, DIANA performs 2-D transient temperature and resultant stress analysis for RCD. Time variability of the mesh geometry is considered in order to simulate successive phases of the structure's construction. The main analysis variables are construction sequence, concrete temperature and ambient temperature. The results show principal tensile stress of hot-weathering concrete is higher than that of cold-weathering concrete. In some case the index of thermal cracking excesses 1.0, RCD also needs thermal management on placing temperature according to weather condition.

MicroRNAs in Human Diseases: From Cancer to Cardiovascular Disease

  • Ha, Tai-You
    • IMMUNE NETWORK
    • /
    • v.11 no.3
    • /
    • pp.135-154
    • /
    • 2011
  • The great discovery of microRNAs (miRNAs) has revolutionized current cell biology and medical science. miRNAs are small conserved non-coding RNA molecules that post-transcriptionally regulate gene expression by targeting the 3' untranslated region of specific messenger RNAs for degradation or translational repression. New members of the miRNA family are being discovered on a daily basis and emerging evidence has demonstrated that miRNAs play a major role in a wide range of developmental process including cell proliferation, cell cycle, cell differentiation, metabolism, apoptosis, developmental timing, neuronal cell fate, neuronal gene expression, brain morphogenesis, muscle differentiation and stem cell division. Moreover, a large number of studies have reported links between alterations of miRNA homeostasis and pathological conditions such as cancer, psychiatric and neurological diseases, cardiovascular disease, and autoimmune disease. Interestingly, in addition, miRNA deficiencies or excesses have been correlated with a number of clinically important diseases ranging from cancer to myocardial infarction. miRNAs can repress the gene translation of hundreds of their targets and are therefore well-positioned to target a multitude of cellular mechanisms. As a consequence of extensive participation in normal functions, it is quite logical to ask the question if abnormalities in miRNAs should have importance in human diseases. Great discoveries and rapid progress in the past few years on miRNAs provide the hope that miRNAs will in the near future have a great potential in the diagnosis and treatment of many diseases. Currently, an explosive literature has focussed on the role of miRNA in human cancer and cardiovascular disease. In this review, I briefly summarize the explosive current studies about involvement of miRNA in various human cancers and cardiovascular disease.

An Inter-floor Noise Prevention System using an Open-source Controller (오픈소스 컨트롤러를 사용한 층간 소음 방지 시스템)

  • Kim, Tae-Hoon;Jang, Hyuk-Jae;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.899-906
    • /
    • 2017
  • This paper proposes an inter-floor noise prevention system using an open-source controller. In the proposed system, Arduino which is a widely used open source controller analyzes sound signals and vibration signals with fast fourier transform. When the magnitude of the band-passed signal excesses the noise reference considering transmission loss of a panel or a wall, the system displays warning messages on an LCD module and a mobile device for users to be aware of the noise condition. In the experiment, the system has succeeded extracting and processing the band-passed signals between 130 Hz ~ 1040 Hz. When the magnitude of the extracted signal that is subtracted from the transmission loss exceeds 45 dB, the system has displayed the warning message on an LCD module and a mobile devicefor noise reduction.

A Feedback Buffer Control Algorithm for H.264 Video Coding (H.264 동영상 부호기를 위한 Feedback 버퍼 제어 방식)

  • Son Nam Rye;Lee Guee Sang
    • The KIPS Transactions:PartB
    • /
    • v.11B no.6
    • /
    • pp.625-632
    • /
    • 2004
  • Since the H.264 encoding adopts both forward prediction and hi-direction prediction modes and exploits Variable Length Coding(VLC), the amount of data generated from video encoder varies as Flaying time goes by. The fixed bit rate encoding system which has limited transmission channel capacity uses a buffer to control output bitstream It's necessary to control the bitstream to maintain within manageable range so as to protect buffer from overflow or underflow. With existing bit amount control algorithms, the $\lambda_{MODE}$ which is relationship between distortion value and quantization parameter often excesses normal value to end up with video error. This paper proposes an algorithm to protect buffer from overflow or underflow by introducing a new quantization parameter against distortion value of H.264 video data. The test results of 6 exemplary data show that the proposed algorithm has the same PSNR as and up to 8% reduced bit rate against existing algorithms.

Analysis of Patient Exposure dose with Glass Dosimeter (Glass Dosimeter를 이용한 환자피폭선량에 관한 분석)

  • Kim, Jae-In;Choi, Won-Keun;Chang, Sung-Won;Oh, Chang-Seop;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • Far reducing medical radiation exposure and managing patient doses, Entrance surface doses(ESDs) were measured at Diagnostic Radiology Department in ASAN medical center, also we determined and compared with the Diagnostic Reference Level(DRL) of some other countries. ESDs were measured far the most common types of X-ray procedures, such as chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA. ESDs were measured by Glass dosimeter and Unfors Xi meter. Those were applied collimation center of phantom's entrance skin surface. The results of ESDs were compared Glass dosimeter with Unfors Xi meter. Those were measured within 5% statistical difference. It seemed well agreement at two devices. In most cases ESDs measured far the different types of X ray procedures were found to be lower than the DRL of IAEA, but ESDs on chest PA, lumbar spine AP, lumbar spine lateral, Pelvis AP, Skull PA were proximity ar excesses at DRL of advanced country. Through this study, we need an investigation and improvement at present diagnostic radiology exam system. Also, radiologists make an effort to reduce patient dose and having a technical skill.

  • PDF