• Title/Summary/Keyword: Excess Oxygen Ratio

Search Result 45, Processing Time 0.02 seconds

Maximal Oxygen Debt, Lactate and Excess Lactate in Men with Low Hematocrit Ratio (헤마토크?????? 비율이 낮은 사람에 있어서 최대 산소 부채와 과잉젖산 사이의 관계)

  • Kim, Dai-Sung;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.53-61
    • /
    • 1968
  • Maximal oxygen debt, lactate and excess lactate were measured in 13 men with low hematocrit ratio before and after maximal exercise. Maximal exercise run was performed on a treadmill and the duration of run was 2 minutes 45 seconds in each subject. Hematocrit ratio ranged between 35 and 47%, the mean being 39.8%. The following results were obtained. 1. Maximal oxygen debt expressed on basis of body weight increased as the hematocrit ratio decreased. The correlation coefficient between the two was r= -0.770. 2. The time necessary for decreasing to 50% of total maximal $O_2$ debt(half time) became longer as the hematocrit ratio decreased. In normal men the half time was about 4 minutes and at the longest it was 12 minutes in men with the lowest hematocrit ratio. 3. The lactate concentration reached its peak value after 3 minutes of recovery. Thereafter, the time course of decrease in lactate concentration coincided roughly with that of respiratory oxygen debt curve. To reach to the resting level, however, it took longer time than that of respiratory oxygen debt. 4. Resting concentrations of lactate was 1.28 mM/l, pyruvate 0.13 mM/l and L/P ratio was 9.8. Peak value of ${\Delta}L$ after exercise reached to the value of 10.4 mM/l and ${\Delta}L/P$ reached 26.0. Peak excess lactate after exercise was 6.34 mM/l. 5. The part of oxygen debt accounted for by the oxygen equivalent of excess lactate was only 38.4%. A better relationship between lactate and oxygen debt was observed and the part of oxygen debt accounted for by the oxygen equivalent of lactate was 63.3%. 6. Peak value of lactate after maximal exercise increased as the hematocrit ratio decreased. 7. Respiratory oxygen debt of 100 ml/kg was accounted for by lactate more than 60% and only 30% was by excess lactate. 8. Excess lactate was not a good index of respiratory oxygen debt.

  • PDF

Experimental study on combustion characteristics of high efficiency oxy-fuel burner (고효율 순산소 버너의 연소 특성에 관한 실험적 연구)

  • Kim, Se-Won;Ahn, Jae-Hyun;Kim, Min-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.57-64
    • /
    • 2002
  • This paper describes the results of a series of experiments executed by using two pilot-scale oxv-fuel burners are designed for maximum capacity of 50,000 kacl/hr, 300,000 kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, swirl vane angle and inlet oxygen temperature on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and inlet oxygen temperature. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, Optimum excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

Experimental Study on the Oxygen Combustion Characteristics with $CO_2$ Feeding ($CO_2$ 첨가에 따른 순산소 연소기의 연소특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.26-34
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below $\lambda=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

Experimental Study on the Effect of $CO_2$ Feeding on the Oxygen Combustion Characteristics by using Inverse Type Multi-hole Burner (역확산 다공 연소기에서 $CO_2$ 첨가에 따른 순산소 연소 특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.162-169
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below ${\lamda}=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

An experimental study on the combustion characteristics using pure oxygen in a turbulent diffusion flame (순산소를 이용한 난류확산화염의 연소 특성에 관한 실험적 연구)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.60-66
    • /
    • 2001
  • Combustion using pure oxygen instead of air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and ultra high temperature flame, being used on the industrial spot. But information about it is not so enough yet. Flame figure, temperature distribution and emission concentration were measured with oxygen excess ratio and swirl number in a turbulent diffusion flame to investigate the combustion characteristics using pure oxygen. The results showed that flame figure became different as long as oxygen excess ratio varied and that concentration of NO and CO increased suddenly around ${\lambda}$=1.5.

  • PDF

Dynamic Analysis of PEM fuel cell system (PEM 연료전지시스템의 동특성 해석)

  • Kim Beomsoo;Jeon Soonil;Lim Wonsik;Park Yeong-il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.353-356
    • /
    • 2005
  • We developed a dynamic model of PEM fuel cell system which can analyze its transient response to dynamic load current. System components such as compressor, air cooler, humidifier, and stack were modeled based on their dynamic equations and performance maps by using Matlab Simulink platform. Through this simulation model, dynamic characteristics of fuel cell system including oxygen excess rat io, stack voltage, and system efficiency were shown. In addition to that, we briefly analyzed the humidity effect on cathode pressure and system efficiency, expecting that this model can be further used to optimize fuel cell system parameters just like operating pressure and temperature, humidity and oxygen excess ratio.

  • PDF

Experimental study on combustion characteristics of oxy-fuel glass melting furnace (순산소를 이용한 유리 용해로의 연소특성에 관한 실험적 연구)

  • Kim, Se-Won;Ahn, Jae-Hyun;Kim, Yong-Mo;Shin, Myung-Chul
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The results of a series of experiments executed by using two pilot-scale oxy-fuel burners are presented. The oxy-fuel burners are designed for maximum capacity of 50,000kcal/hr, 200,000kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, and swirl vane angle on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple at various points of the flame. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and momentum. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, optimum burner type, excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

The effects of oxygen-concentration increased by oxygen-enriching membrane on combustion of S.I. engines (기체분리막에 의해 상승된 산소농도가 스파크점화기관의 연소에 미치는 영향)

  • 권병철;김형섭
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.74-80
    • /
    • 1992
  • The purpose of this study is to improve the performance of gasoline engine. Combustion-characteristics orignated from supplying cylinder with fuel-air mixture which was formed by the rise of oxygen-concentration in air with oxygen-enriching membrane have been investigated. The results showed that the poor-limit of oxygen-concentration was increased by shortening combustion-duration because the rise of oxygen-concentration in fuel-air mixture resulted in the promotion of combustion-velocity. Also, the generation of large output of power was expected from combustion in proportion as the amount of oxygen was increased.

  • PDF

Effects of endurance training for 4weeks on resting metabolic rate and excess post-exercise oxygen consumption in mouse

  • Jeon, Yerim;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.16 no.2
    • /
    • pp.113-122
    • /
    • 2012
  • This study assessed the amount of energy consumed and fat deposition after endurance training in order to review the effect of 4-week endurance exercise on resting metabolic rate of a mouse during and after exercise and the effect of exercise. A total of 19 seven-week-old ICR male mice were used as the study subject. Those mice were divided into sedentary group (Sed) and trained group (Tr) after a week of environment adaption. The Tr group was trained with endurance exercise five times a week for four weeks. Weight and the amount of food intake were daily weighed and resting metabolic rate and metabolic rate after exercise were assessed before starting exercise and on the fourth week after training. Metabolic rate during exercise were measured four weeks after training. At the end of breeding period, statistically significant difference was shown in weights of trained and sedentary groups (p < 0.05). During a resting period, no significant difference was shown in oxygen intake, respiratory exchange ratio, and the amount of carbohydrate and fat oxidized. Moreover, no significant difference was shown in excess post-exercise oxygen consumption (EPOC) of an hour period after training. In contrast, the maximal oxygen uptake (VO2 max) was approximately 11.1% higher in trained group after training compare to before. However, there was no significant difference in respiratory exchange ratio and carbohydrate and fat oxidization. During exercise, oxygen uptake, carbon dioxide production, and respiratory exchange ratio in energy metabolism during exercise showed no significant difference. However, significant difference was exhibited in the amount of fat oxidized in both groups. Summing up those results, endurance exercise could be concluded to be effective in weight control. However, weight loss is thought to be resulted from increase in fat oxidization during exercise unlike the conclusion made from previous studies where weight loss is prominently influenced by energy metabolism during a resting period and increased fat oxidation during post-exercise recovery. All experimental procedures were carried out at the Animal Experiment Research Center of Konkuk University. This study was conducted in accordance with the ethical guidelines of the Konkuk University Institutional Animal Care and Use Committee.