• 제목/요약/키워드: Excess Air Factor

검색결과 26건 처리시간 0.019초

저개도 카뷰레터 쓰로틀에서의 26cc 소형원동기의 공기과잉율에 따른 성능특성 (Performance of 26cc Small Sized Two-Stroke SI Engines on Excess air factor at partial opened carburetor throttle)

  • 최영하;김병국;조형문;윤석주;김동선;한종규
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.409-412
    • /
    • 2008
  • This paper presents the effects of excess air factors(0.84${\sim}$0.90) and opened throttle area ratios(AR=0.15${\sim}$0.25) on the emission and performance of a small spark-ignition gasoline engine. The engine used in this paper was a single cylinder, diaphragm carburetor, two-stroke, air-cooled 26cc engine for brush cutter. The rpm, torque, fuel consumption and CO emission were measured under the four different excess air factors and three different opened area ratios conditions on the engine loads respectively. The results showed that the rpm was decreased and torque was increased at increasing load, the maximum power and minimum fuel consumption could be obtained critical rpm on each throttle opened area ratios and brake specific fuel consumption was decreased 13${\sim}$17%, CO emissions was decreased 21${\sim}$38% at excess air factor 0.90 than 0.84.

  • PDF

배기가스 터빈과급 디젤기관의 성능해석에 관한 연구 (A Study on the Performance Analysis of Diesel Engine Supercharged by Exhaust Gas Thrbine)

  • 안진근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.421-429
    • /
    • 1997
  • This study is theoretically examined the influences on the performance of diesel engine super¬charged by exhaust gas turbine with the change of excess air factor, admission ratio, total efficien¬cy of turbine and compressor, scavenging pressure ratio, and scavenging temperature. In this study, all calculations are carried out by computer, and the theoretical engine performance is com¬pared with the actual engine performance which is offered from engine manufacturer. Following results are acquired by this study. The mean effective pressure is increased with decrease of excess air factor or increase of scavenging pressure ratio. As the admission ratio or total efficiency of tur¬bine is increased, the mean effective pressure is increased but the specific fuel consumption is decreased. Mean calculation error compared with the actual engine performance is under 5 per¬cents, therefore, this calculation method can be used in the design of diesel engine.

  • PDF

직접분사식 가솔린엔진에서 운전조건에 따른 바이오에탄올의 연소 및 배기배출물 특성 (Effect of Engine Operating Conditions on Combustion and Exhaust Emission Characteristics of a Gasoline Direct Injection(GDI) Engine Fueled with Bio-ethanol)

  • 윤승현;박수한
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.609-615
    • /
    • 2015
  • 본 연구는 직접분사식 가솔린엔진에서 공기 과잉률 및 바이오에탄올-가솔린 혼합연료의 혼합비에 따른 연소특성과 배기배출물 특성을 실험적으로 규명한 것이다. 다양한 공기 과잉률 및 혼합비 조건에서 실험을 수행하였으며, 연소실 압력, 열발생률, 연료소비율 등을 통해 연소특성을 분석하였으며, 배기배출물 특성은 미연탄화수소(HC), 일산화탄소(CO), 질소산화물($NO_x$) 분석을 통해 확인하였다. 혼합연료의 실험결과는 100% 가솔린 및 바이오에탄올 실험결과와 비교하였다. 실험결과 최고연소압력과 열발생률, 제동연료소비율은 혼합비의 증가에 따라 증가하였으며, CO, HC, $NO_x$와 같은 배기배출물은 바이오 에탄올 혼합비율이 증가함에 따라 감소하였다. 혼합연료의 배기배출물 수준은 가솔린 보다 낮게 나타났다.

코안다 노즐을 이용한 배기가스 재순환 버너의 연소 유동 특성 및 NOx 저감에 관한 연구 (A Study on the Combustion Flow Characteristic and NOx Reduction of the Exhaust Gas Recurculation Burner using Coanda Nozzles)

  • 하지수
    • 한국가스학회지
    • /
    • 제21권3호
    • /
    • pp.53-60
    • /
    • 2017
  • 연소로에서 질소산화물을 저감하기 위하여 여러 가지 방법으로 연구가 진행되어 오고 있는데 그 중에 배기가스를 재순환하여 저감하는 방법이 있다. 본 연구는 배기가스를 재순환하는 방법으로 연소로 외부에 코안다 노즐을 이용하여 배기가스를 재순환 유입하는 방법을 사용하였다. 코안다 노즐을 이용하여 배기가스를 재순환하고 혼합가스는 연소로 접선 방향으로 투입하여 선회유동을 유발하는 특징을 가지는 배기가스 재순환 버너이다. 이러한 버너에서 연소로 내의 선회 유동 특성을 살펴보고 온도와 반응속도 분포를 살펴봄으로써 코안다 노즐을 이용한 재순환 버너의 연소 유동 특성을 규명하였다. 과잉공기계수와 코안다 노즐 간격을 변화하여 배기가스 재순환 유입량 특성을 살펴보았으며 과잉공기계수를 증가하면 재순환 유입량비가 증가하였고 코안다 노즐 간격을 증가하면 코안다 노즐 공기 출구에서 속도가 낮아져서 재순환 유입량이 감소한다는 특성을 알았다. 배기가스 출구에서 평균온도는 코안다 노즐 간격 변화에 거의 무관하며 과잉공기계수 증가에 따라 감소하는 것을 알았다. 이러한 특성으로 배기가스 출구에서 NOx 농도는 과잉공기계수 증가에 따라 현저히 감소하고 코안다 노즐 간격에는 상대적으로 영향이 적은 것으로 나타났다.

우리나라에서의 증발식 냉각의 효용성

  • 민만기
    • 대한설비공학회지:설비저널
    • /
    • 제3권3호
    • /
    • pp.199-208
    • /
    • 1974
  • The effectiveness with which evaporative cooling can be used in Korea was analysed by making use of weather data of 15cities in a past decade. In ASHRAE comfort chart for a still air atmospheric condition was divided into two dimensional array, 14 zones by effective temperature and 10 zones by relative humidity, and all hours of weather condition in those zones were. computed from every 4 hours weather data in a past decade. From this computation obtained were for 15 cities : 1. average annual total hours above $23^{\circ}C$ ET 2. effective temperatures with $5\%$ excess factor, and 3. ratios of all hours in wet (above $25.6^{\circ}C$ WBT), intermediate $(22^{\circ}C\;to\;25.6^{\circ}C\;WBT)$, and dry $(below\;22^{\circ}C\;WBT)$ area to total hours in whole area on comfort chart beyond $23^{\circ}C$ ET to effective temperature of $5\%$ excess factor. It was shown from this computational result that in Korea evaporative cooling was not effective for building and residential comfort air conditioning but could be useful for comfort air conditioning in industry and industrial air conditioning, depending upon the air stream velocity and the type of application.

  • PDF

메탄올 使용時 의 電氣점火機關 의 性能 에 關한 硏究 (Performance of a Spark Ignition Engine Fueled with Methanol)

  • 유병철
    • 대한기계학회논문집
    • /
    • 제6권2호
    • /
    • pp.121-132
    • /
    • 1982
  • Engine torque, specific fuel consumption and MBT spark advance of a domestic automotive engine fueled with methanal-gasoline blends or straight methanal were studied under steady state condition and compared to those obtained with gasoline. The effects of adding methanal to gasoline on engine performance were studied with or without any carburetor modification. At first, the engine was operated without any modification. Next, the diameters of metering orifices in carburetor were modified to give the same excess air factor regardless of fuel type under each fixed engine operating condition. Finally, the diameters of metering orifices in carburetor were modified to give the same excess air factor for 15% mixture of methanal in gasoline by volume as for gasoline with standard metering orifices in carburetor. The effects of adding methanal to gasoline on engine torque, specific energy consumption and MBT spark advance can be explained on the basis of change in stoichiometry caused by the addition of methanal to gasoline.

Effects of Sintering Atmosphere on Piezoelectric Properties of 0.75BF-0.25BT Ceramic

  • Kim, Dae Su;Kim, Jeong Seog;Cheon, Chae Il
    • 한국세라믹학회지
    • /
    • 제53권2호
    • /
    • pp.162-166
    • /
    • 2016
  • 0.75BF-0.25BT ceramics were prepared by sintering at $980-1040^{\circ}C$ in air or under atmosphere powder. A sample with 1 mole %-excess $Bi_2O_3$ was also prepared to compensate for $Bi_2O_3$-evaporation. Physical and piezoelectric properties of these three samples were compared. When the sintering temperature increased from $980^{\circ}C$ to $1040^{\circ}C$, the density of the sample sintered in air decreased continuously due to Bi-evaporation. Due to the suppression of Bi-evaporation, the sample sintered under atmosphere powder had a higher density at sintering temperatures above $1000^{\circ}C$ than did the sample sintered in air. The addition of 1 mole %-excess $Bi_2O_3$ successfully compensated for Bi-evaporation and kept the density at the higher value until $1020^{\circ}C$. Grain size increased continuously when the sintering temperature increased from 980 to $1040^{\circ}C$, irrespective of the sintering atmosphere. When the sintering temperature increased, the piezoelectric constant ($d_{33}$) and the electromechanical coupling factor ($k_p$) increased for all samples. The sample with 1 mole % excess-$Bi_2O_3$ showed the highest density and the best piezoelectric properties at sintering temperature of $1020^{\circ}C$.

압축비 변화에 따른 HCNG 엔진의 배기 특성 (Emission Characteristics of HCNG Engine with Compression Ratio Change)

  • 이성원;임기훈;박철웅;최영;김창기
    • 한국자동차공학회논문집
    • /
    • 제21권4호
    • /
    • pp.106-112
    • /
    • 2013
  • Compression ratio is an important factor affecting engine performance and emission characteristics since thermal efficiency of spark ignition engine can be theoretically improved by increasing compression ratio. In order to evaluate the effect of compression ratio change in HCNG engine, natural gas engine was employed using HCNG30 (CNG 70 vol%, hydrogen 30 vol%). Combustion and emission characteristics of CNG and HCNG fuel was analyzed with respect to the change of compression ratio at each operating condition. The results showed that thermal efficiency improved and $CH_4$, $CO_2$ emission decreased with the increase in compression ratio while $NO_x$ emissions were decreased at a certain excess air ratio condition. Higher thermal efficiency and further reduction of exhaust emissions can be achieved by the increase of compression ratio and the retard of spark timing.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권2호
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

냉동기유 주입량과 냉매 충진량에 따른 냉동기 성능 평가 (Effects of Refrigerant and Oil Charges on the Performance of an Refrigeration System)

  • 선종관;채수남;정동수
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.617-625
    • /
    • 2002
  • In this study, effects of refrigerant and oil charges on the performance of a refrigeration system simulating an automobile air conditioner have been experimentally investigated using R134a and PAG oil. Measurements were taken in a breadboard type refrigeration test unit with a compressor used for a commercial automobile air-conditioner under a set of condition imposed upon normally to automobile air conditioners. Both the COP and capacity decreased rapidly as the oil charge increased because of the decrease in vapor pressure of the circulating refrigerant/oil mixture. The excess oil left in the evaporator also caused heat transfer degradation resulting in a decrease in capacity and in turn COP. It was found that there is an optimum refrigerant charge at which the COP becomes the maximum. Below this optimum charge, both the capacity and COP increased as the refrigerant charge increased and above the optimum charge, both of them remained almost constant. Hence, the COP seems to be the most important factor in determining the optimum refrigerant charge. When the system was undercharged, the refrigerant at the condenser exit lost subcooling and showed a sign of poor miscibility.