• 제목/요약/키워드: Evoked potentials (EPs)

검색결과 6건 처리시간 0.021초

블라인드 식별을 이용한 유발 전위 추출에 관한 연구 (A Study on the Detection of Evoked Potential using Blind Identification)

  • 우용호;김택수;김현슬;최윤호;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1310-1312
    • /
    • 1996
  • In this study, the algorithm for detection of evoked potentials is proposed. The observed evoked potentials are first preprocessed by blind identification so as to eliminate the ongoing EEG Bile noise. Then, statistic characteristics of the peak components i.e latency and amplitude are detected from prefiltered responses by latency-corrected averaging method. The performance of blind identification is compared with those of adaptive fillers as to deterministic and stochastic EPs, is assessed in terms of NMSE, distortion index, correlation coefficient with original EPs. The estimated deterministic and stochastic EPs restored with peak components are compared and assessed. The results show the superiority of this proposed algorithm using blind identification in detecting deterministic and stochastic EPs.

  • PDF

Evoked potential: basic requirements and guidelines for writing reports

  • Lee, Eun-Mi;Seok, Hung Youl;Park, Kee Duk;Seo, Dae-Won;Korean Society of Clinical Neurophysiology Education Committee
    • Annals of Clinical Neurophysiology
    • /
    • 제20권1호
    • /
    • pp.18-25
    • /
    • 2018
  • Evoked potentials (EPs) measures the electrophysiologic responses of the nervous system to variety of stimuli. In clinical practice, only a few are used on a routine basis. Because of the small amplitude of EPs recorded by noninvasive methods, computer summation or averaging generally is necessary to resolve them from background noise. Therefore, waveform acquisition under good condition according to standard method is important. We aimed to provide the standards for clinical EP equipment, technical consideration and minimal requirements for obtaining good clinical EP waveforms, and general criteria for writing EP reports in practice as Korean guidelines.

임상 체성감각 유발전위 검사 (Clinical Somatosensory Evoked Potential)

  • 류재관;김종순
    • 대한물리치료과학회지
    • /
    • 제3권1호
    • /
    • pp.907-918
    • /
    • 1996
  • Evoked potentials(EP) are defined as electric responses of the nerves system to sensory stimulation. EPs are used mainly to test conduction in the visual, auditory, and somatosensory systems, especially in the central parts of these systems. Somatosensory evoked potentials (SEP) are the potentials elicited by stimulation of peripheral nerves and recorded at various sites along the sensory pathway. SEPs types consist mainly of SEPs to electric stimulation of arm or leg nerves. SEPs to arm stimulation are usually recorded simultaneously from clavicular, cervical, and scalp electrodes; SEPs to leg stimulation are recorded from lumbar, low thoracic, and scalp electrodes. Subject variables that have practical impotance are age, limb length, body height, and temperature. General clinical interpretation of abnormal SEPs wave decreases of peripheral conduction time, and abolition of SEPs recorded from different levels to identify lesions of peripheral nerves, plexus, nerve root, spinal cord, cauda equina, hemispheric brainstem, and cerebral parts of the somatosensory pathway.

  • PDF

경막혈종 및 뇌내압 증가에 따른 청각 유발전위의 분석 (EVALUATION OF AUDITORY EVOKED POTENTIALS IN WHITE NEW ZEALAND RABBITS WITH SIMULATED SUBDURAL HEMATOMA AND INCREASED INTRACRANIAL PRESSURE)

  • 임재중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.171-174
    • /
    • 1992
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs), as a means of diagnosing traumatic head-injured patients. The experiment entails surgically plating two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peat latencies ($P_1-P_6$) and five negative peak latencies ($N_1-N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of changes on AEP peak latencies is due to mechanical forcer of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP.

  • PDF

비침습적 뇌내압 측정 시스템의 개발을 위한 청각유발전위와 경막혈종간의 상관관계 분석에 관한 연구 (A Correlational Study between Auditory Evoked Potential and Subdural Hematoma for the Diveloprnent of a Noninvasive ICP Monitoring System)

  • 임재중
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 1995
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs) as a means of diagnosing traumatic head-injured patients. The experiment entails surgically placing two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peak latencies ($P_1 - P_6$) and five negative peak latencies ($N_l- N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining. a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of ch, mges on AEP peak latencies is due to mechanical forces of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP itself.

  • PDF

유발전위 뇌파 신호의 추출을 위한 구간 래이턴스 교정 평균가산 (Segments latency corrected average for evoked potentials)

  • 이용희;이두수
    • 전자공학회논문지S
    • /
    • 제34S권10호
    • /
    • pp.89-97
    • /
    • 1997
  • To extract time-varying evoked potential (EP), segement latency corrected average method is presented. This method is composed of three steps. First, adaptive filtering for reducing the effect of artifacts and removing background noise is performed. Next, validated intervals of individual segments are aligned, and latency components are detected by cross-correlation between the previously obtained and measured EPs within the intervals. Finally, after the detected latency component, responses of segments are groupe and averaged, the shole corrected EP signal is obtained. In the experiments, the resutls of the conventional methods including simple averaging, Woody's method, and peak component latency corrected averaging are obtained, the results compared with the present method for evaluating performance. Therefore, the presented method confirms that it reflects the latency variations of fundamental peaks and gets the improved EP.

  • PDF