• 제목/요약/키워드: Evaporation performance

검색결과 446건 처리시간 0.024초

증발냉각에 의한 공랭 응축기의 성능향상 가능성에 관한 연구 (Cooling Enhancement Potential of an Air-Cooled Condenser by Evaporative Cooling)

  • 이대영;백영진;김영일
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This paper describes the potential advantages in applying evaporative cooling to air-cooled condensers. The cooling characteristics of an air-cooled condenser with its surface fully covered with thin water film are investigated and compared with that of an air-cooled condenser with usual dry surface. By applying the evaporative cooling, the cooling performance of the condenser is shown to improve enormously. When the outdoor air is 35$^{\circ}C$ and 40% in relative humidity, the condensing temperature of the refrigerant is decreased by 2$0^{\circ}C$. Even when the incoming air is fully saturated with water vapor, the evaporation from the wet surface occurs to cause a decrease in the condensing temperature by 1$0^{\circ}C$. The main reason for this improvement is assessed as the addition of an efficient cooling mechanism which is the water evaporation resulting in latent heat absorption.

유기 EL 성막 공정을 위한 점 증발원의 DSMC 시뮬레이션 (DSMC Simulation of a Point Cell-source for OLED Deposition Process)

  • 전성훈;이응기
    • 반도체디스플레이기술학회지
    • /
    • 제9권3호
    • /
    • pp.11-16
    • /
    • 2010
  • The performance of an OLED fabrication system strongly depends on the design of the evaporation cell-source. Therefore, necessity of the preceding study for cell source development of new concept is becoming increase. A development plan to substitute for experiment is applied as use simulation. In this study interpret behavior of a particle through DSMC techniques, and in this paper presenting a form to make so as to have better performance of the pointtype cell source which had a nozzle.

연료전지 다공성막을 통한 수분증발량의 정량적 측정에 관한 실험적 연구 (Development of System for Measuring Evaporation Rate through Porous Medium in Fuel Cells)

  • 김종록;김무환;손상영
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.579-582
    • /
    • 2012
  • 연료전지 시스템에서 잔류 수분의 제거과정은 연료전지의 성능 및 수명 관리를 위해 중요한 과정이다. 효과적인 수분 제거과정의 설계를 위해서는 연료전지내의 수분 제거 특성에 대한 이해가 필수적이다. 이를 위해 본 연구에서는 연료전지의 다공성막인 가스확산층을 통한 수분증발량을 정상상태에서 측정하는 실험 기법을 개발하였다. 이 기법을 이용하여 연료전지의 잔류수분 제거 현상을 모사하는 실험장치를 개발하였다. 그리고 건조가스와 가스확산층의 변수가 수분에 미치는 영향을 실험적으로 측정하였다. 건조가스의 습도가 낮고, 유량이 높을수록 가스확산층을 통해 증발되는 수분량이 높았다. 또한 가스확산층의 두께가 얇을수록 수분 증발량이 높은 특성을 확인하였다.

태양열 활용 증발기의 성능 향상을 위한 국소적 젖음성 제어에 관한 실험적 연구 (Performance Enhancement of Solar-Driven Steam Generator by Local Wettability Control)

  • 최진욱;서용원;모형욱;김설하
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.255-259
    • /
    • 2022
  • 태양광을 이용한 증기 발생 방법은 순수한 물이 고갈되는 현재 사회에서 해수나 폐수에서 물을 수확할 수 있는 매우 유망한 기술이다. 태양광을 이용한 증기 발생 중에서 멤브레인을 이용한 증류법은 현재 개발 중에 있지만 멤브레인이 물과 직접 접촉하여 효율적인 증발량을 늘리기가 어려웠다. 본 연구에서는 PDMS (polydimethylsiloxane)와 산화 그래핀(GO)으로 구성된 태양열 멤브레인 증기 발생기와 부분적으로 멤브레인 전체에 절친 젖음성 제어를 통해 증발량을 개선하는 것을 제안하여 실험적 연구를 수행했다. 국부적인 젖음성 제어로 태양광과의 열교환 영역에서 열 국지화 및 온도 상승에서 상당한 개선을 보여주었다. 1sun(=1000 W/m)의 조사에서 1.54 kg m-2 h-1의 증발 능력을 갖습니다. 그 결과, 태양열 멤브레인 증기 발생 시스템은 국부적인 물 회수 성능 메커니즘을 이해 및 실험적 확인을 수행할 수 있었다.

소실모형주조법에 의한 내마모 복합조직층 형성에 미치는 공정인자의 영향 (Effects of Parameters on Abrasion-Resistant Layer of Composite Structure Formed by Evaporation Pattern Casting)

  • 최창영;모남규;김건호;윤종천;정유현;김동혁;최용진;이인규;조용재
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.89-94
    • /
    • 2018
  • Due to industrial advancement and environmental concerns, there is a demand for light-weight material parts with high-performance characteristics. In order to meet this demand, various studies have been conducted on developing high-performance castings to achieve composite features by coating only specific parts that require high performance, with dissimilar joining, rather than coating the entire material part. This study analyzed the possibility of forming a local composite layer on an aluminum alloy through evaporation pattern casting, and the effects of parameters on the aluminum alloy.

지열을 이용한 코일 침적형 히트펌프의 성능 특성 (Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy)

  • 오후규;이동건;전민주;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.437-444
    • /
    • 2012
  • 본 논문은 지열을 이용한 코일 침적형 히트펌프 시스템의 운전변수에 대한 최적 설계를 위해서 히트펌프의 성능 특성을 실험적으로 조사하였다. 본 연구에서 고려된 작동변수로는 과냉각도, 증발온도, 응축온도 등이다. 그 실험결과를 요약하면 다음과 같다. 지열 이용 코일 침적형 히트펌프 시스템의 증발온도와 과냉각도가 증가할수록, 응축온도는 감소할수록 성능계수는 증가함을 알 수 있다. 즉, 지열 이용 코일 침적형 히트펌프 시스템의 증발온도, 응축온도, 과냉각도는 냉방과 난방의 성능계수에 영향을 미치는 것을 알 수 있다. 따라서 본 연구에서 제안하는 히트펌프 시스템이 최고의 성능을 나타내기 위한 최적의 운전조건을 결정할 필요가 있다.

액화수소 저장탱크의 수평요동이 증발 특성에 미치는 영향에 대한 연구 (A Study on the Effect of Evaporation of Liquid Hydrogen Tank Related to Horizontal Sinewave)

  • 오승준;권준영;윤정환
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.155-161
    • /
    • 2023
  • Recently, a study on alternative and renewable energy is being conducted due to energy depletion and environmental problems. In particular, a hydrogen has the advantage of converting and storing the remaining energy into water-electrolyzed hydrogen through renewable energy generation. In general, due to reasons such as insulation problems, a study on high-pressure hydrogen storage tanks and related parts has recently been conducted. However, in the case of liquid hydrogen, the volume can be reduced by about 800 times or more compared to high-pressure hydrogen gas, so the study on this is needed as a technology that can increase energy density. In this study, the evaporation characteristics were analyzed under fixed heat flux conditions for liquid hydrogen storage tanks and the change in thermal stratification according to sloshing was analyzed. The heat flux condition was fixed at 250 W/m2 and the horizontal resonance frequency of the primary mode was applied to the storage tank. As a result, it was confirmed that the thermal stratification phenomenon decreased compared to the case where the slashing was not present due to forced convection when the slashing was present.

과산화수소 추력기용 촉매의 건조 조건 변화에 따른 성능 변화 (Performance variation of catalyst for hydrogen peroxide thruster with drying condition)

  • 이정섭;안성용;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2009
  • 과산화수소를 일원 추진제로 사용하는 추력기용 촉매의 건조 조건에 따른 성능 변화에 대한 실험을 수행하였다. 사용한 촉매는 백금이며 촉매 지지체는 펠렛 타입의 알루미나이다. 일반적인 촉매 제작 방법인 증발건조법을 사용하였으며, 이 때 건조 조건에 따른 촉매의 성능을 평가하였다. 촉매 제작 조건 중 pH 값이 낮은 경우 촉매 제작이 유리하였기 때문에 다양한 산성 용액에서 촉매를 담지 해 실험을 수행하였다. 건조 온도는 각각 25, 50, 70, $90^{\circ}C$이며 실험 결과 $90^{\circ}C$에서 건조한 경우 높은 성능을 보임을 알 수 있었다. 이는 빠른 증발속도로 인해서 백금이 결정화를 이루지 못하고 고르게 분산되었기 때문으로 판단된다.

  • PDF

수중 하베스트형 빙축열 시스템의 운전특성 실험 (Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System)

  • 최인수;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

Utilization Of Ethane As Working Fluid At Two-Stage Cascade Vapour Compression System

  • Kim, Yeong-Geun;Shin, You-Sik;Jeong, Hyo-Min;Chung, Han-Shik;Lubi, Rahadiyan
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.414-420
    • /
    • 2005
  • For supporting future demands of lower temperature. environmental friendly low- temperature refrigerants must be studied and developed to replace halocarbon. Ethane. which is one of hydrocarbon compound. is an environmental friendly refrigerant because it has zero ODP and GWP ${\sim}$ 20[per 100yr]. On this study, two-stage cascade refrigeration system was utilized to investigate performance of ethane on the low-stage. By employing R22 at higher stages. energetic performance as well as operating condition of R22/R170 system is compared to R22/R23. At low stage evaporation pressure ranges from 1.10 to 2.74 bar, R22/R170 shows higher COP over R22/R23. Furthermore, at the same range evaporation temperature R22/R170 can reach lower temperature.

  • PDF