Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation

  • Yeon, Jei-Won;Jung, Sang-Hyuk
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1689-1695
    • /
    • 2017
  • As a part of evaluating the volatility of iodide ions subjected to gamma irradiation, $I_2$ evaporation experiments were performed with $I_2$ and $I^-$ mixed solutions in the temperature range $26-80^{\circ}C$ in an open, well-ventilated space. The evaporation of $I_2$ was observed to follow primarily first order kinetics, depending on the $I_2$ concentration. The evaporation rate constant increased rapidly with increase in temperature. The presence of $I^-$ slightly reduced the evaporation rate of $I_2$ by forming relatively stable $I_3^-$. The effect of $Cl^-$ at <1.0 wt% on $I_2$ evaporation was insignificant. The evaporation rate constants of $I_2$ were $1.3{\times}10^{-3}min^{-1}\;cm^{-2}$, $2.4{\times}10^{-2}min^{-1}\;cm^{-2}$, and $8.6{\times}10^{-2}min^{-1}\;cm^{-2}$, at $26^{\circ}C$, $50^{\circ}C$, and $80^{\circ}C$, respectively.

Investigation of Geometrical Properties on Deposition Rate in Cesium Iodine Film (증착속도에 따른 CSI layer의 기하학적 특성 연구)

  • Lee, Kyu-Hong;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Yul;Cho, Sung-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.415-417
    • /
    • 2003
  • CsI 형광체는 X선에 대한 분해능 및 변환효율이 우수한 물질이다. 최근 대면적 평판형 X선 영상검출기의 변환층으로 이용하기 위해 CsI 형광체의 대면적 제조에 대한 연구가 활발히 진행되고 있다. 본 논문은 진공 열증착법을 이용하여 증착속도(3, 3.8, $4.5\;{\mu}m/min$)에 따라 $20\;{\mu}m$ 두께의 CsI 필름을 제조하였고, XRD 및 SEM 분석을 통해 CsI 필름의 기하학적 구조를 조사하였다. 증착된 CsI 필름은 증착속도에 관계없이 복잡한 다결정 구조를 가지며, $3\;{\mu}m/min$의 증착속도에서 약 $1\;{\mu}m$ 크기로 needle-like 한 columnar structure를 가졌다. As results, about 3um/min evaporation rate formed as good geometry characteristics CsI layer.

  • PDF

Iodine Deposition onto the Chinese Cabbage (요오드의 배추에 대한 침적)

  • Lee, Han-Soo;Choi, Heui-Joo;Kang, Hee-Suk;Yu, Dong-Han;Keum, Dong-Kwon;Lim, Kwang-Mook;Park, Hyo-Kook;Choi, Yong-Ho;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.3
    • /
    • pp.173-177
    • /
    • 2004
  • The Chinese cabbage, being one of the principal foodstuffs in Asian countries, is tested for iodine exposure. As a radioactive source, iodine-125 of which the radiological half life is 60 days was used to measure the concentration change. Experiments were carried out four times with different times of exposure. The iodine source was prepared by the chemical reaction of NaI in order to avoid producing relatively large iodine which might be generated In the case of crystal evaporation. The deposition velocity was obtained from the integrated air concentration and surface concentration of the Chinese cabbage. The environmental half life was also calculated.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF

Quantitative Analysis of Soluble Residues by Correction of Starch Content in Paperboard Grade (전분 함량 보정을 통한 판지류의 가용성 잔류물질 정량 분석)

  • Lim, Chae-Hoon;Park, Joung-Yoon;Lee, Tai-Ju;Um, Gi Jeung;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.6
    • /
    • pp.78-87
    • /
    • 2013
  • Even though the notice No. 2010-11 of the Ministry of Food and Drug Safety Administration that has been applied to analyze the content of the water soluble residue eluted from multi-layer paperboard was abolished in 2011, its application for the analysis on evaporation residue is still valid. There are very high possibilities that the noticed existing method gives the misleading result on the evaporation residue due to the water soluble starch eluted from the multi-layer paperboard. The quantitative analysis on water-soluble residue with starch content correction has been carried in the study using UV/Vis spectroscopy and HPLC. The UV/Vis spectroscopy absorbance analysis showed the large amount of the oxidized starch obtained from the aqueous residue eluted out of the multi-layer paperboard after the iodine, ${\alpha}$-amylase reaction, and starch hydrolysis. The residual content decreased by the correction through the enzyme hydrolysis.

Purification of Bunsen Reaction Products in Sulfur-Iodine Hydrogen Production Process (황-요오드 수소 제조 공정에서 분젠 반응 생성물의 정제)

  • Cha, Kwang-Seo;Kim, Young-Ho;Kang, Young-Han;Kim, Hyo-Sub;Park, Chu-Sik;Bae, Ki-Kwang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.158-166
    • /
    • 2010
  • The purification of two liquid phases ($H_2SO_4$ phase and HIx phase) formed from a Bunsen reaction in Sulfur-Iodine (SI) hydrogen production process was investigated in order to operate SI process efficiently. The each synthetic solution for two liquid phases contained impurities was prepared on the basis of a proper composition obtained from Bunsen reaction. The purification of each solution was performed by counter-current flow using a packed column at different temperatures and $N_2$ flow rates. As the results of purification, impurities existed in each phase were decreased with increasing the temperature and the $N_2$ flow rate. In particular, the increase of the $N_2$ flow rate at the lower temperatures was effective to remove impurities by a reverse Bunsen reaction without side reactions. On the whole, it may be concluded that the purification of each phase is accomplished by mixing effects of the stripping, the evaporation, and the reverse Bunsen reaction.

2 Liquid Phase Purification Characteristics for Sulfur-Iodine Thermochemical Hydrogen Production (황-요오드 열화학 수소체조 공정에서 2 액상 정체 특성)

  • Lee, Kwang-Jin;Cha, Kwang-Seo;Kang, Young-Han;Park, Chu-Sik;Bae, Ki-Kwang;Kim, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.69-72
    • /
    • 2007
  • The objective of this work was to study the properties of purification of two liquid phase for exclusion of impurities in each phase. The experiments for process variables were carried out in the temperature range($H_{2}SO_{4}$ phase: $413{\sim}513$ K, $HI_{x}$ phase: $353{\sim}453$ K) and in the $N_{2}$ flow rate range($H_{2}SO_{4}$, $HI_{x}$ phase: $50{\sim}200$ mL/min). As the results, it is appeared that the principles of $H_{2}SO_{4}$ phase purification was due to stripping, evaporation and reverse bunsen reaction and $HI_{x}$ phase purification was due to stripping and reverse bunsen reaction. In purification of $H_{2}SO_{4}$ phase, the concentration rate of $H_{2}SO_{4}$ phase was controled by temperature but the temperature had few effects on yield of $H_{2}SO_{4}$. In purification of $HI_{x}$ phase, we observed products of side reactions($H_{2}S$, S) over 433 K. The purity of $HI_{x}$ phase was increased with increasing $N_{2}$ flow rate because impurites were decreased with increasing conversion of reverse reaction.

  • PDF

Effects of Solubility of SO2 Gas on Continuous Bunsen Reaction using HIx Solution (HIx 용액을 이용한 연속식 분젠 반응에 미치는 SO2용해도의 영향)

  • KIM, JONGSEOK;PARK, CHUSIK;KANG, KYOUNGSOO;JEONG, SEONGUK;CHO, WON CHUL;KIM, YOUNG HO;BAE, KI KWANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.13-21
    • /
    • 2016
  • The Sulfur-Iodine thermochemical hydrogen production process (SI process) consists of the Bunsen reaction section, the $H_2SO_4$ decomposition section, and the HI decomposition section. The $HI_x$ solution ($I_2-HI-H_2O$) could be recycled to Bunsen reaction section from the HI decomposition section in the operation of the integrated SI process. The phase separation characteristic of the Bunsen reaction using the $HI_x$ solution was similar to that of $I_2-H_2O-SO_2$ system. On the other hands, the amount of produced $H_2SO_4$ phase was small. To investigate the effects of $SO_2$ solubility on Bunsen reaction, the continuous Bunsen reaction was performed at variation of the amounts of $SO_2$ gas. Also, it was carried out to make sure of the effects of partial pressure of $SO_2$ in the condition of 3bar of $SO_2-O_2$ atmosphere. As the results, the characteristic of Bunsen reaction was improved with increasing the amounts and solubility of $SO_2$ gas. The concentration of Bunsen products was changed by reverse Bunsen reaction and evaporation of HI after 12 h.

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.