• 제목/요약/키워드: Evaporation Heat

검색결과 619건 처리시간 0.028초

태양열 집열기용 열파이프의 구조와 작동 특성에 관한 연구 (A Study on Design and Performance of a Heat pipe for the application to Solar collector)

  • 임광빈;김철주;박이동;황영규;강환국
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.70-78
    • /
    • 1993
  • Heat pipes, applied to flat plate solar collectors, have a long and slender configuration with relatively low heat flux on the evaporator. Such a heat pipe has a tendency to build-up a liquid pool at the lower half of evaporator zone, and at this pool occurs such complicated phenomena of evaporation and fluid dynamics as superheat, sudden generation of bubble, its likely explosive growth process and flooding etc. In the present study, we tried to solve those problems by means of adjusting the two principle design parameters, liquid fill charge and wick length, using 4 heat pipes and 3 thermosyphons, with different values of parameter respectively. The corresponding results can be summarized as followings, - The thermal conductance of heat pipes was largely improved by el eliminating wick from adiabatic and condenser zone. - But on evaporator zone wick is inevitable to reduce behavior of the build -up of liquid pool , where arise diverse internal complex phenomena. - The liquid fill charge should have to be increased by 10∼20% more than the quantity to saturate the wick.

  • PDF

한국서해의 해양과 대기간 에너지의 효과 (Sea-air Energy Exchange in the Eastern Yellow Sea)

  • 이동영;장선덕
    • 수산해양기술연구
    • /
    • 제12권2호
    • /
    • pp.37-42
    • /
    • 1976
  • Each term of heat badget equation in the eastern Yellow Sea was calculated and the variation in relation to meteorological condition was shown for the period from September 1973 to February 1974, At Mal-do near Gunsan the maximum heat exchange occurred at the last ten days of December (--522 1y/day), while at Sunmi-do near Incheon it occurred at the middle ten days of November (--665 1y /day), The contribution of the sensible heat to total heat exchange increased rapidly, while the effect of cloudiness decreased to be negligible in winter. The values of the heat exchange fluctuated considerably with the periodic occurrence of the cold Siberiaa air mass. The mean evaporation heat estimated indirectly from the aerological data was 32 ly/day at the northern part and 269 ly/dlY at the southern part of the Yellow Sea in December 1973.

  • PDF

발전기 폐열 이용 소형 해수담수화장치 개발 (Development of Seawater Distiller utilizing Waste Heat of Portable Electric Generators)

  • 박창대;임병주
    • 대한기계학회논문집B
    • /
    • 제34권6호
    • /
    • pp.607-613
    • /
    • 2010
  • 도서지역에서 많이 사용하고 있는 소형 발전기의 폐열을 열원으로 이용하는 소용량 자급형 해수담수화장치의 설계 자료와 성능실험 결과를 제시하였다. 제안된 담수기는 조밀간격 수직형 평행평판이 복수단으로 구성된 다중효용방식으로서, 해수가 흐르는 윅(wick)이 부착되어 있다. 복수단의 평판에서 증발과 응축과정이 반복적으로 일어나므로 열에너지를 재이용하게 되어 담수생산량을 증가시킨다. 제안된 담수기의 성능실험 결과 5.6 kVA 발전기의 폐열이 담수화의 증발열원으로 사용될 수 있음을 알 수 있었고, 1중 효용만으로 최소 6.7 kg/day의 담수를 생산할 수 있었다. 이 결과는 10중 효용의 경우 약 35~44 kg/day를 기대할 수 있는 양으로서, 동일 전열면적의 태양열 증류기의 일일 최대 생산량보다 약 16~4배 많은 것이다.

낙동강 중류에서 하천 증발이 안개에 미치는 영향 (The Influence of Evaporation from a Stream on Fog Events in the Middle Nakdong River)

  • 박준상;김규랑;강미선;김백조
    • 한국지구과학회지
    • /
    • 제38권6호
    • /
    • pp.395-404
    • /
    • 2017
  • 본 연구에서는 구미에 위치한 낙동강에서 발생한 안개를 분류하였고 안개 발생 전후의 기상특성을 분석하였다. 안개는 2013년부터 2015년까지 시정계를 이용하여 관측되었다. 안개는 총 74회 발생하였고 대부분 증기안개로 분류되었다. 관측된 증기 안개는 내륙에서 발생한 안개보다 지속시간이 길게 나타났는데 이는 지형적 특징으로 인해 야간 증발이 다른 지역보다 강하게 나타났기 때문이다. 안개 지속시간에 대한 하천 증발 효과를 분석하기 위해 Penman-Monteith(Penman법)와 Bulk aerodynamic (Bulk법) 방법을 사용하여 증발량을 추정하였다. 이 중 Bulk법은 실제 수면에서 측정한 증발량과 유사하게 나타났다. 따라서 Bulk법이 실제 수면 증발량 추정에 적합한 방법임을 확인할 수 있었다. Bulk법으로 추정한 증발량은 안개 비발생일 보다 안개 발생일에 06 LST와 07 LST에 더 높게 나타났다. 안개 발생일에 하천의 증발은 대기에 증발잠열 에너지를 공급하고 안개 내부의 난류를 유지하는 에너지원으로 작용한다. 이와 같은 결과는 안개내부의 풍속, 기온, 그리고 난류운동에너지의 증가를 통해 확인하였다.

Intake Valve Temperature Effect on the Mixture Preparation in a SI Engine During Warm-up

  • 신영기
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.51-66
    • /
    • 1997
  • A heat transfer model of the intake valve in a spark ignition engine is presented, which is calibrated with a number of the valve temperature profiles measured during engine warm-up for the gaseous fuel(propane). The valve is divided into four identical elements for which the assumption of lumped thermal mass is applied. The calibration is made so that the difference between the measued and simulated valve temperatures becomes minimal. Then the model is applied to the cases of the liquid fuel(indolene) to estimate the amount of the liquid fuel vaporized from the intake valve by assuming that fuel evaporation accounts for the deficit of the heat balance budget. The results of the model show quantitative contribution of each heat transfer source to the heat balance. The behavior of the calculated mass fraction of the fuel vaporized from the intake valve explains how the liquid fuel evaporate during engine warm-up. The mass fraction at warmed-up condition is closely related with the fraction directly targeted on the valve back by the fuel spray geometry.

  • PDF

Modeling of the Drying Process in Paper Plants

  • Hwang, Ki-Seok;Yeo, Yeong-Koo;Yi, Sung-Chul;Dongjun Seo;Hong Kang
    • 펄프종이기술
    • /
    • 제35권5호
    • /
    • pp.53-61
    • /
    • 2003
  • In this study a model for the drying process in paper production plants was developed based on the mass and heat balances around drying cycles. Relationships for the heat transfer coefficients between the web and the air as well as between the drying cylinder and the web were extracted from the closed-loop plant operation data. It was found that the heat transfer coefficients could be represented effectively in terms of moisture content, basis weight and reel velocity. The effectiveness of the proposed model was illustrated through numerical simulations. From the comparison with the operation data, the proposed model represents the paper plant being considered with sufficient accuracy.

비흡입시 연소하는 담배의 열분해 작용에 관한 수학적 모델 (A Mathematical Model for Pyrolysis Processes During Unforced Smoldering of Cigarette)

  • 이성철
    • 한국연초학회지
    • /
    • 제17권2호
    • /
    • pp.160-169
    • /
    • 1995
  • A mathematical model for the pyrolysis processes during unforced smoldering of cigarette was proposed in this study by analyzing the physical model of the smoldering cigarette (including the establishment of burning front between burning zone and pyrolysis zone, and analyzing the involvement of main factors such as pyrolysis of virgin tobacco, evaporation of water, and internal heat transport in the processes). Thermal conduction of cigarette paper and convective and radiative heat transfer at the outer surface were also considered via the thermal resistance law for the competitive heat transfer mechanisms. The governing partial differential equations were solved using an integral method. Model predictions of smoldering speed, or linear burn rate, as well as temperature and density profiles in the pyrolysis zone for different kinds of cigarettes were found to be close to the experimental data in the literature (Muramatsu, 1981). The model provides a relatively fast and efficient way to simulate the pyrolysis processes and offers a practical tool for exploring important parameters for a smoldering cigarette, such as blended tobacco composition, properties of cigarette paper, and heat flux from the burning zone to the pyrolysis zone.

  • PDF

모듈형 수관식 보일러를 위한 열교환 모듈의 열전달 특성 (Heat Transfer Characteristics of Heat Exchange Module for a Water Tube Type Modular Boiler)

  • 안준;김종진;강새별
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 2012
  • A finned tube type heat exchange module has been proposed for a multi-burner water tube boiler. Fin density and length increase in streamwise direction to equalize the evaporation for each module, which makes it difficult to apply conventional bulk design procedure. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also conducted to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, since the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.