• Title/Summary/Keyword: Evaporation Cooling System

검색결과 82건 처리시간 0.145초

스팀 에젝터에 의한 강제 증발 방식의 냉각 특성에 관한 연구 (Study on Cooling Charcteristics of Forced Evaporation by using Steam Ejector)

  • 손호재;이윤환;김영근;정효민
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.41-46
    • /
    • 2006
  • This study shows a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water by about $5^{\circ}C\;from\;25^{\circ}C$ or higher. In this research, to replace the present water cooling system, we focused on a water cooling system by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are depended on the vacuum pressure in the enclosed tank, and the cooling water is generated by latent head of evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8$ mmHg using a steam driven ejector with jet condenser.

  • PDF

밀폐용기내의 물의 저압 증발 최적조건에 관한 실험적 연구 (An Experimental Study on the Water Evaporation Conditions of the Enclosed Tank)

  • 김세현;신유식;이윤환;정한식;정효민
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 2004
  • Cooling towers are widely used not only for cooling products and equipment in manufacturing process but HVAC(Heating, Ventilation and Air Conditioning) system. As a cooling tower is the terminal apparatus which discharges heat from industrial process, the efficiency of heat exchange in the cooling tower greatly affects to the overall performance of a thermal system. In this paper, we constituted a new water cooling system by using a Latent heat of evaporation in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driven ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows into the ejector. Based on the vacuum pressure by water driven ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF

농축산물의 저장 및 유통을 위한 감압증발 급냉각 시스템에 관한 연구 (A Study on the Rapid Cooling Vacuum System for the Storage and Transportation of the Cold Agriculture and Livestock Products)

  • 김성규;김원녕;김경석;최순열;전현필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권1호
    • /
    • pp.26-36
    • /
    • 1997
  • Recently, the new refrigerating system, using non - fluorinated hydrocarbon refrigerants has to be developed for the agricultural fields. One of that kinds of systems is the cooling system using the water vapor and vacuum, in which the water evaporate at the low temperature under vacuum and absorb the large amount of the latent heat. If vapor with large amount of latent heat is removed from the system, the system is cooled accordingly. The characteristics of cooling under the vacuum was observed and measured using experimental apparatus, which is consisted of vacuum chamber, the ejectors, the pumps and the measurement apparatus. As the results of experiments, we know that the evaporation in the vacuum occurs vigorously when the materials to be cooled has more amounts of heat before cooling, and by which effects the materials can be cooled. The cooling vacuum system is more efficient than other methods when the agricultural products is chilled or dried.

  • PDF

재생증발식 수냉각기의 냉각성능 해석 (Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler)

  • 최봉수;홍희기;이대영
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

다공층의 증발냉각 열전달에 관한 해석적 연구 (Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer)

  • 김홍제;이진호
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.104-111
    • /
    • 1992
  • 본 연구에서는 외부 열입력(external heat input)의 조건하에서 증발분출냉각 시스템에서 나타나는 3개의 영역, 즉 증기, 증발 및 액체영역을 고려한 이론해석을 행 함으로써 증발분출냉각 시스템의 열전달 특성을 정성적으로 조사하고자 하였다.

재생증발실 냉각기의 구조에 따른 최적설계 비교 (Comparison of Optimum Design due to the Structure of the Regenerative Evaporative Cooler)

  • 최봉수;홍희기;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.359-364
    • /
    • 2005
  • In dehumidification evaporation cooling system. the regeneratie evaporative cooler(REC) makes an important role to reduce the sensible cooling load in the system through evaporative cooling, By this reason, many studies about increasing the cooling capacity of the REC were undertook. In this paper, we analyzed the cooling characteristics of the REC due to the structures of the REC and determined the best structure for the REC's effectiveness and cooling capacity. From the study. we could obtain some important results: at first. corrugated type has the benefit to expand the channel width of the REC, But because the type has some weak points about the size and weight. there is almost no benefit to improve the performance of the REC. Through these reasons. we decided that finned type is the best structure to improve the performance of the REC.

  • PDF

하절기 기화냉각장치 설치에 따른 가스터빈 성능변화 (Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season)

  • 정현조;유호선;문승재
    • 플랜트 저널
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 본 연구는 하절기 가스터빈 압축기 입구에 설치된 기화냉각장치로 인하여 저하된 공기온도가 가스터빈 성능에 어떠한 변화를 미치는지에 대하여 해석하였다. 연구 대상은 인천화력본부 가스터빈 3호기이며, 기종은 Siemens SGT6-4000F(V 84.3A)이다. 기화냉각장치 설치 전후를 비교하기 위하여 특설계측기를 설치하였으며, 2015년 8월 3일에서 14일까지 11시부터 15시 사이에 대기온도 $29{\pm}1^{\circ}C$ 조건에서 설치 전후 각각 5회씩 총 10회에 걸쳐 정밀성능시험을 시행하고 각각의 평균값을 적용하였다. 시험 결과, 가스터빈 압축기 입구 공기온도 $4.12^{\circ}C$ 저하로 공기 밀도가 증가되어 압축기 압력비는 0.27 증가, 압축기 효율은 0.29 %p 상승, 가스터빈 엔탈피강하 효율은 0.31 %p 증가하였고, 가스터빈 효율은 0.44%p, 출력은 4,489 kW가 증대되는 효과를 얻을 수 있었으며, 습도 및 유동저항 증가에 따른 영향은 미미하였다.

  • PDF

온실 포그냉방시스템의 냉방효과 예측을 위한 CFD 모델의 개발 (Development of CFD Model for Estimation of Cooling Effect of Fog Cooling System in Greenhouse)

  • 유인호;김문기;권혁진;김기성
    • 생물환경조절학회지
    • /
    • 제11권2호
    • /
    • pp.93-100
    • /
    • 2002
  • 본 연구에서는 포그냉방시스템을 수치적으로 시뮬레이션하기 위한 CFD 모델을 개발하였으며, 포그냉방온실에서 측정된 데이터에 의해 개발된 모델의 유효성을 검증하였다. 또한 분무수온, 분무수량, 분무정지시간과 분무입자의 증발률이 포그냉방시스템의 성능에 미치는 영향을 알아보기 위해 개발된 모델을 적용하였다. 시뮬레이션 결과에 의하면, 각 측점에서 실측치와 예측치의 온도차가 무차광조건에서는 $0.1~1.4^{\circ}C$, 차광조건에서는 $0.2~2.3^{\circ}C$였으며, 상대습도차는 무차광조건에서는 0.3~6.0%, 차광조건에서는 0.7~10.6%였다. 예측치가 실측치와 비교적 잘 일치하는 것으로 나타나 개발된 모델이 포그냉방시스템의 냉방효과를 예측할수 있는 것으로 판단된다. 포그냉방시스템 성능은 분무수량, 분무정지시간과 분무입자의 증발률의 영향을 많이 받지만 분무수온의 영향은 받지 않는 것으로 나타났다.

Development of Heat Transfer and Evaporation Correlations for the Turbulent Natural Convection in the Vertical Channel by Using Numerical Analysis

  • Kang, Han-Ok;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.532-541
    • /
    • 1996
  • Theoretical and numerical study on heat transfer and evaporation in the vertical channel has been carried out and basic correlations have been derived for the heat transfer evaluation of PCCS. Analysis program was developed with low-Reynolds-number k-$\varepsilon$ model and surface transfer rates were calculated for the turbulent natural convection in the vertical channel. In relation to dry cooling by buoyancy-driven air, first, the system parameters which govern overall heat transfer rate are determined through the adequate nondimensionalization procedure. After comparison with existing experimental data, numerical results are used to derive heat transfer correlation by sensitivity calculations. In relation to wet cooling by falling water film, numerical analysis are carried out for evaporation process with real film surface conditions and evaporation correlation is derived through analogy concept and correction factors.

  • PDF

Numerical Analysis on the Flow Characteristics in Steam Ejector

  • Shin, You-Sik;Jin, Zhen-Hua;Chun, You-Sin;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.749-754
    • /
    • 2006
  • This study performed of a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water in aquafarm by about $5^{\circ}C$ from $25^{\circ}C$ or higher in this research, to replace the present water cooling system, Ive focused on a water cooling system operated by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are dependent on the vacuum pressure in the enclosed tank, and the cooling water is generated by evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8mmHg$ using a steam driven ejector with jet condenser in experiments. The obtained results are respectively ${\Delta}T=7^{\circ}C$, ${\Delta}T=5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4L/M. The obtained results are respectively ${\Delta}T=5.5^{\circ}C$, ${\Delta}T=5.5^{\circ}C$ and ${\Delta}T=5.5^{\circ}C$ at heat exchanger flow rate 4.5L/M.

  • PDF