• Title/Summary/Keyword: Evaluation standards

Search Result 2,535, Processing Time 0.045 seconds

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

A Study on LRFD Reliability Based Design Criteria of RC Flexural Members (R.C. 휨부재(部材)의 L.R.F.D. 신뢰성(信賴性) 설계기준(設計基準)에 관한 연구(研究))

  • Cho, Hyo Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1981
  • Recent trends in design standards development in some European countries and U.S.A. have encouraged the use of probabilistic limit sate design concepts. Reliability based design criteria such as LSD, LRFD, PBLSD, adopted in those advanced countries have the potentials that they afford for symplifying the design process and placing it on a consistent reliability bases for various construction materials. A reliability based design criteria for RC flexural members are proposed in this study. Lind-Hasofer's invariant second-moment reliability theory is used in the derivation of an algorithmic reliability analysis method as well as an iterative determination of load and resistance factors. In addition, Cornell's Mean First-Order Second Moment Method is employed as a practical tool for the approximate reliability analysis and the derivation of design criteria. Uncertainty measures for flexural resistance and load effects are based on the Ellingwood's approach for the evaluation of uncertainties of loads and resistances. The implied relative safety levels of RC flexural members designed by the strength design provisions of the current standard code were evaluated using the second moment reliability analysis method proposed in this study. And then, resistance and load factors corresponding to the target reliability index(${\beta}=4$) which is considered to be appropriate level of reliability considering our practices are calculated by using the proposed methods. These reliability based factors were compared to those specified by our current ultimate strength design provisions. It was found that the reliability levels of flexural members designed by current code are not appropriate, and the code specified resistance and load factors were considerably different from the reliability based resistance and load factors proposed in this study.

  • PDF

Monitoring of Heavy Metals Migrated from Glassware, Ceramics, Enamelware, and Earthenware (유리제, 도자기제, 법랑 및 옹기류 재질의 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Cho, Kyung Chul;Jo, Ye-Eun;Park, So-Yeon;Park, Yongchjun;Park, Se-Jong;Lee, Hye Young
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • This study investigated the migration levels of lead (Pb), cadmium (Cd), and arsenic (As) from food contact articles (glassware, ceramics, enamelware, and earthenware) into a food stimulant (4% v/v, acetic acid). Migration tests were performed at 25℃ for 24 h and all analyses were performed using Inductively-Coupled Plasma Mass Spectrometry (ICP-MS). The method was validated by linearity of calibration curves, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. In glassware, the migration concentrations ranged from not-detected (N.D.) to 752.21 ㎍/L and N.D. to 1.99 ㎍/L for Pb and Cd, respectively. In ceramics, the migration concentrations ranged from N.D. to 1,955.86 ㎍/L, N.D. to 74.06 ㎍/L, and N.D. to 302.40 ㎍/L for Pb, Cd, and As, respectively. In enamelware, the migration concentrations ranged from N.D. to 4.48 ㎍/L, N.D. to 7.00 ㎍/L, and N.D. to 52.00 ㎍/L for Pb, Cd, and Sb, respectively. In earthenware, the migration concentrations ranged from N.D. to 13.68 ㎍/L, N.D. to 0.04 ㎍/L, and N.D. to 6.71 ㎍/L for Pb, Cd, and As, respectively. All results were below the migration limits of Korea standards and specifications for food utensils, containers, and packages.

Ecological Health Assessment Based on Fish Assemblages Along with Total Mercury Concentrations of Zacco platypus in Miho Stream (어류 군집을 이용한 미호천의 생태 건강성 평가 및 피라미(Zacco platypus)의 총수은 함량)

  • Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.288-297
    • /
    • 2010
  • This study was to evaluate the ecological stream health through the Multimetric Fish Assessment Index (MFAI) along with fish fauna analysis based on the tolerance and trophic guilds at Miho stream in 2008 and 2009. Also, we analysed total mercury concentration in fish tissues to examine heavy metal contamination. Total sampled fish were 40 species and 2,557 individuals and Zacco platypus was the most dominant with 35% relative abundance. It was sampled with 11.4% RA for Korean endemic species (10 species 291 individuals) less than average RA 39.3% for the Geum river watersheds. According to the tolarance guild analysis, tolerant species was more dominant with 58.9% RA (15 species, 1,507 individuals) than sensitive species with 6.6% RA. Trophic guild analysis also suggested that omnivores were more dominant (60.5% RA) than insectivores (31.5% RA). Riffle-benthic species was also sampled with 7.7% RA. Ecological stream health based on the MFAI were averaged 25.3 (n=3) with fair-poor condition in 2008 and also 26.3 (n=3) with fair condition in 2009, just slightly increased than 2008. Qualitative habitat evaluation index was averaged 134 (n=3) with fair condition but most of sites had sediment accumulation that reflected substrate degradations proceeding. From the result of total mercury accumulation in fish tissues, kidney and liver tissues showed the highest but the lowest for gill tissues. Overall mercury concentration were not exceed the national standards by Korean Federation of Drug and Administration (KFDA). Consequently, our result could correspond with the characteristics of Miho stream where point sources such industrial complexes and wastewater treatment plant widely distributed around the stream along the gradient of up and downstream.

A Study on the ICAO international aviation safety policy, a change of paradigm and the government response to the direction (ICAO 국제항공안전정책 패러다임의 변화 분석과 우리나라 신국제항공안전정책 검토)

  • Chang, Man-Heui;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.73-96
    • /
    • 2013
  • ICAO's Universal Safety Oversight Audit Programme (USOAP) was initially launched in January 1995, in response to widespread concerns about the adequacy of aviation safety oversight around the world. The recent reduction in aircraft accidents and effective role that is evaluated on the basis of these results, and in 2013 the existing 'snapshot approach' to 'regular monitoring system (USOAP-Continuous Monitoring Approach)' was converted to. ICAO aviation safety assessment of the state in today's international community 'aviation safety credibility' as objective indicators to judge the enormous impact on the aviation industry, the state is not satisfactory, especially if the results of the evaluation and expansion of code-share airline ban, reduced international air transit passengers, including premium increases business and economic penalties should. In addition, ICAO implementation of the existing laws and regulations(Prescriptive Approach), but based on the Risk-based prevention model, Proactive Approach introduced the concept of aviation safety system, including international aviation safety policy has been to switch paradigms. This new ICAO international aviation safety policy also applies to the Government of the Republic of Korea in line with the aviation safey policies have changed. In particular, the systematic implementation of safety management for the existing laws and regulations in the center of the safety oversight system of risk-based introduction of the concept of proactive safety management, and According to international standards ICAO aviation service providers operate their own Safety Management System was set out in Aviation Law ever. In addition, the aviation safety is at the center of the field of the safety of aircraft operations and maintenance for the promotion is promoting various safety policies. This new paradigm shift in the international aviation safety policy in line with our state in the international community with the most exemplary aviation safety system firmly established itself as a model, the Government will strengthen the competitiveness of our aviation plans to support. To do this, the government, airlines, aviation officials try all the practical effect would be expected.

  • PDF

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

The Standard of Judgement on Plagiarism in Research Ethics and the Guideline of Global Journals for KODISA (KODISA 연구윤리의 표절 판단기준과 글로벌 학술지 가이드라인)

  • Hwang, Hee-Joong;Kim, Dong-Ho;Youn, Myoung-Kil;Lee, Jung-Wan;Lee, Jong-Ho
    • Journal of Distribution Science
    • /
    • v.12 no.6
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose - In general, researchers try to abide by the code of research ethics, but many of them are not fully aware of plagiarism, unintentionally committing the research misconduct when they write a research paper. This research aims to introduce researchers a clear and easy guideline at a conference, which helps researchers avoid accidental plagiarism by addressing the issue. This research is expected to contribute building a climate and encouraging creative research among scholars. Research design, data, methodology & Results - Plagiarism is considered a sort of research misconduct along with fabrication and falsification. It is defined as an improper usage of another author's ideas, language, process, or results without giving appropriate credit. Plagiarism has nothing to do with examining the truth or accessing value of research data, process, or results. Plagiarism is determined based on whether a research corresponds to widely-used research ethics, containing proper citations. Within academia, plagiarism goes beyond the legal boundary, encompassing any kind of intentional wrongful appropriation of a research, which was created by another researchers. In summary, the definition of plagiarism is to steal other people's creative idea, research model, hypotheses, methods, definition, variables, images, tables and graphs, and use them without reasonable attribution to their true sources. There are various types of plagiarism. Some people assort plagiarism into idea plagiarism, text plagiarism, mosaic plagiarism, and idea distortion. Others view that plagiarism includes uncredited usage of another person's work without appropriate citations, self-plagiarism (using a part of a researcher's own previous research without proper citations), duplicate publication (publishing a researcher's own previous work with a different title), unethical citation (using quoted parts of another person's research without proper citations as if the parts are being cited by the current author). When an author wants to cite a part that was previously drawn from another source the author is supposed to reveal that the part is re-cited. If it is hard to state all the sources the author is allowed to mention the original source only. Today, various disciplines are developing their own measures to address these plagiarism issues, especially duplicate publications, by requiring researchers to clearly reveal true sources when they refer to any other research. Conclusions - Research misconducts including plagiarism have broad and unclear boundaries which allow ambiguous definitions and diverse interpretations. It seems difficult for researchers to have clear understandings of ways to avoid plagiarism and how to cite other's works properly. However, if guidelines are developed to detect and avoid plagiarism considering characteristics of each discipline (For example, social science and natural sciences might be able to have different standards on plagiarism.) and shared among researchers they will likely have a consensus and understanding regarding the issue. Particularly, since duplicate publications has frequently appeared more than plagiarism, academic institutions will need to provide pre-warning and screening in evaluation processes in order to reduce mistakes of researchers and to prevent duplicate publications. What is critical for researchers is to clearly reveal the true sources based on the common citation rules and to only borrow necessary amounts of others' research.

The Development of National Competency Standard(NCS) Regarding Casino Operations Management (카지노운영관리 직무에 관한 국가직무능력표준(NCS) 개발)

  • Kim, Dong-Yeon;Oh, Seung-Gyun;Koo, Ja-Gil;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.39 no.1
    • /
    • pp.143-163
    • /
    • 2014
  • This study developed a National Competency Standard(NCS) regarding the casino operations management based on the manual for developing National Competency Standard of 13 years and a revised classification system chart of the National Competency Standard. For the research method, this study developed a national competency standard of relevant jobs after going through review, consultation, modification, supplementation, and reporting procedures 10 times with development experts of the National Competency Standard, the industrial setting professionals, education and training experts, qualification(job analysis) experts, facilitators, and a working group of job verification committee based on the phased range and DACUM procedure of study. The major development results of this study are as follows. First, this study selected and defined duties based on the revised classification system chart of the National Competency Standard, then drew and developed total 8 ability units based on the applicable duties. Secondly, based on the developed ability units, total 27 ability unit factors were deduced and developed. Thirdly, a standard system by ability unit factor was developed based on the level of the national competency standard and revised classification system chart, then this study deduced and developed a supra-domain of the standard system by competency units using the standard tranquility value by these competency unit factors. Based on such development contents and guidelines for the national competency standard ability unit classification number, this study deduced and developed category numbers by relevant competency unit. Fourthly, total 27 relevant performance standard by competency units and knowledge, skill, and attitude were deduced and developed. Fifthly, this study deduced and developed a scope of application, work situation, evaluation guide, core competency, and development history in reference to the total 8 relevant competency units based on the duties.