• Title/Summary/Keyword: Evaluation contrast effect

Search Result 159, Processing Time 0.035 seconds

Preparation and Evaluation of Aclarubicin Liposome using Microfluidizer (마이크로플루다이저를 이용한 아클라루비신 리포좀의 제조 및 평가)

  • Park, Mork-Soon;Park, Jin-Kyu;Lee, Gye-Won;Baek, Myoung-Ki;Jee, Ung-Kil
    • YAKHAK HOEJI
    • /
    • v.42 no.3
    • /
    • pp.265-274
    • /
    • 1998
  • In order to attain a sustained release at targeted organs in a prolonged time which can reduce the side effects and maximize the therapeutic effect, aclarubicin (ACL) was entrap ped into liposomes of different lipid compositions using Microfluidizer, and dry liposomes were prepared by lyophilization. The dry aclarubicin-entrapped liposomes were evaluated in terms of mean particle size and size distribution, entrapment efficiency and in vitro drug release profile. The Entrapment efficiency of liposome, when the concentration of aclarubicin and lipid were 0.5 to 1.0mg/ml and $200{\mu}mol$/ml, respectively, was over 80% using Microfluidizer, in contrast to 70% of entrapment efficiency using hand-shaking method. Mean particle size and size distribution of aclarubicin-entrapped liposomes of various lipid compositions did not change considerably by the freeze drying. The range of particle size was between 80 and 200nm. Among aclarubicin-entrapped liposomes, ACL-liposome of PC/DPPC/CH0L/TA displayed the most significant sustained release. The addition of DPPC appeared to be favorable for the control of release. In general, aclarubicin entrapped in liposomes was less stable than free aclarubicin either in pH 7.4 phosphate buffer or in human plasma. Formulation I($t_{1/2}$, 20.3 hr) devoid of lipid additive was the most unstable in the phosphate-buffer solution while formulation II($t_{1/2}$, 40.7 hr) with cardiolipin was the most stable. Half lives of aclarubicin-entrapped liposomes in human plasma were 43.2, 50.7, 35.9 and 35.3 hr for formulation I. II, III and IV, respectively, in contrast to 57.8 hr for free aclarubicin.

  • PDF

Contrast-Enhanced MR Angiography of Supra-Aortic Arteries: Review of Current Techniques, Diagnostic Accuracy and Common Pitfalls in Steno-Occlusive Diseases

  • Lee, Jeong-Hyun;Kim, Jin-Hyoung;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, ang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.

  • PDF

Properties and Preservation of the Plain Bread Changed by the Addition of Chrysanthemum Powder (국화분말을 첨가한 빵의 특성과 저장중의 품질 변화)

  • Jung, Sang-In;Shin, Eun-Ju;Choi, Sun-Uk
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.197-201
    • /
    • 2010
  • 0%, 3%, 5%, and 7% chrysanthemum powder was added to plain bread to investigate its effect on the quality and preservation of bread. The properties of dough, physical changes, and sensory evaluation of plain bread with chrysanthemum powder added were analyzed during storage at room temperature. Volumes of dough and bread were decreased by addition of chrysanthemum powder. Also, the pH and Hunter L (lightness) in bread with chrysanthemum powder were lower than those of the control bread, while its redness, yellowness, and hardness were higher. In sensory evaluation, when more than 5% chrysanthemum was added to bread, aftertaste and overall acceptability were rapidly decreased. In contrast, the addition of chrysanthemum minimized the drop of flavor caused by storage time. In conclusion, chrysanthemum powder added to plain bread improved flavor, which declines with storage time.

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease (다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가)

  • Hong, Inki;Park, Minji;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

Evaluation of the Usefulness of a Wireless Signal Device for the Use of Contrast Agent in Computed Tomography (전산화단층촬영에서 조영제 주입에 따른 무선신호기 사용의 유용성평가)

  • Hong, Ki-Man;Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.417-425
    • /
    • 2018
  • The psychological anxiety of radiologists, as well as the patients, is growing with the increasing use of CT contrast agent side effects and the process of extravasation. In this study, a satisfaction survey was conducted regarding the wireless signal device after CT examination in patients and radiologists by employing a wireless signal device during a contrast-enhanced CT examination in order to determine its usefulness to the relieve psychological anxiety, such as anxiety and fear, of patients and radiologists when using contrast agents. The use of a wireless signal device was also intended to help radiologists in dealing with the side effects of contrast agents that may occur during a CT examination and preventing extravasation. Patients aged 20 years or older, who visited the C university hospital in Jeonnam province for 4 months from August to November in 2017, were surveyed. A total number of 90 patients (57 males and 33 females),who agreed to the study after CT examination, were included in the questionnaire survey. Meanwhile, 15 radiologists, who were working at a CT room and had an experience in using a wireless signal device, were surveyed. Patient satisfaction was $6.01{\pm}0.88$ before the use of a wireless signal device and $8.20{\pm}1.06$ after use, thereby showing an increased satisfaction after its use. Radiologist satisfaction was $8.46{\pm}1.06$ after use, thereby not showing a big difference from the mean patient satisfaction. The satisfaction was high at over 8 points in both groups. The contribution to psychological stability with the use of a wireless signal device was $8.98{\pm}0.65$ in patients with prior experience of side effects and $8.00{\pm}1.21$ in patients without prior experience of side effects. In conclusion, it is considered to improve satisfaction with the examination by helping the radiologists in taking immediate action with calling via the wireless signal device and providing the patients and radiologists with psychological stability by reducing their anxiety.

Usefulness Evaluation of Application of Metallic Algorithm Reducing for Beam Hardening Artifact Occur in Typical Brain CT Image (머리 CT영상에서 흔히 발생하는 선속경화인공물 감소를 위한 금속인공물감소 알고리즘 적용의 유용성 평가)

  • Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.389-395
    • /
    • 2018
  • The study attempted to use computed tomography images to determine the usefulness of the reduction in the axial reduction algorithm in the event of a metallic artifacts reduction in the image of the beam-hardening effect, which is known as the most effective method of reducing metallic artifact reduction in the image and the reduction of the metal produced in this study. As a result, the result is increased to 140 kVp to reduce the value of the CT value by 0.02 to 0.05 %, resulting in decreased axial effect (P > 0.05). The CT value decreased from 12.4 to 26.9 % when applied to the reduction of the metallic. 12.4 to 26.9 % (p<0.05). In addition, in the qualitative assessment by the clinical trial evaluation, it was assessed as 1.8 points after applying the MAR algorithm, In the resolution of resolution and contrast evaluations, the estimation of the decrease in metallic artifact effects was assessed as the metal was assessed to be scored 7.2 points after the MAR algorithm was evaluated. Therefore, in case of artifacts due to irreversible beam hardening effect, it is useful to reduce artifacts caused by beam hardening effect by using various methods derived from existing researches and scanning by applying the metal artifact reduction algorithm proposed in this experiment.

Evaluation of Genetic Effects of Demographic Bottleneck in Muzzafarnagri Sheep from India Using Microsatellite Markers

  • Arora, R.;Bhatia, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Genetic variability is an important component in the ability of populations to adapt in the face of environmental change. Severe human impacts reduced Muzzafarnagri sheep of India from 500,000 in 1972 to 10,989 in 1973-74. Here we report for the first time the effect of this population decline on levels of genetic variability at 13 FAO recommended ovine microsatellite loci and contrast levels of variability to that in a breed from the same geographical region, which differed in numbers, by an order of magnitude (Marwari sheep). Of the 13 loci, 100% were polymorphic in both breeds. A high degree of genetic variation was observed within populations in terms of both allele diversity (number of alleles per locus, >4) and gene diversity (expected heterozygosity, >0.5), which implied that there is still a substantial amount of genetic diversity at the nuclear loci in a declining population. Nevertheless, overall low number of alleles per locus and relatively less abundance of low frequency alleles in Muzzafarnagri sheep suggested that genetic variability has been comparatively reduced in this population. Bottleneck analysis indicated that a genetic bottleneck did not occur during the most recent decline. In addition, we found that the differentiation among populations was moderate ($F_{ST}$= 11.8%). This study on assessment of genetic effects of the population declines in ovines is a step towards identification of genetically impoverished or healthy populations, which could prove to be a useful tool to facilitate conservation planning in this important species of small ruminants.

Evaluation of Metal Biosorption Efficiency of Laboratory-grown Microcystis under Various Environmental Conditions

  • Pradhan, Subhashree;Singh, Sarita;Rai, Lal Chand;Parker, Dorothy L.
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 1998
  • This study examines the effect of pH, temperature, metal ion concentration and culture density on metal biosorption by the nuisance cyanobacterium Microcystis aeruginosa. Ni biosorption was higher at pH 9.2 than at neutral and acidic pH. In contrast the biosorption of Cu and Zn was maximum at pH 7.0. However, biosorption of Zn was difficult to measure at pH values 9.2 and 10.5, owing to the formation of insoluble complexes. All the test metals (Cu, Zn, and Ni) showed maximum biosorption rate at low culture densities of 40 mg dry wt $1^{-1}$. The biosorption of Cu, Zn, and Ni was maximum at $40^{\circ}C$. However, no worthwhile difference in Zn and Ni sorption was noticed at 4 and $29^{\circ}C$ as compared to $40^{\circ}C$. Of these three metals used Microcystis showed a greater binding capacity ($K_{f}$ value=0.84, Freundlich adsorbent capacity) and accelerated biosorption rate for Cu under various environmental conditions. Fitness of mathematical models on metal biosorption by Microcystis confirmed that the biological materials behave in the same way as physical materials. These results suggest that before using a biosorbent for metal recovery, the environmental requirements of the biosorbent must be ascertained.

  • PDF

Ultrasonographic Evaluation of Surgically Induced Cranial Cruciate Ligament Rupture in the Dog (개에서 전십자 인대 단열의 초음파적 평가)

  • 성윤상;엄기동;장광호
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.229-232
    • /
    • 2003
  • Ultrasonographic examination of the stifle joint four clinically and radiographically normal adult dogs was performed before and after inducing the cranial cruciate ligament (CrCL) rupture of the bilateral stifle surgically. At Pre- or post-surgery, the hyperechoic patella ligament and the echogenic infrapatella fat interfered the visualization of the CrCL by the plain scanning method. However when the stifle joint was imaged by the scanning method injecting normal saline within the joint capsule, the hyperechogenic ligament was visualized by the separation of the infrapatella fat and the CrCL and the contrast effect of anechoic saline. When the stifle joint was imaged by the real time scanning method after the induction of the surgical rupture, fluttering of the ligament and anechoic area between the bone and the CrCL was identified due to the lack of tonicity and continuity of the ligament. Enlargement of the ligament because of its increased diameter as well as fluttering of the CrCL and the increased joint space's thickness was visualized. Consequently, confirming fluttering of the CrCL, increased ligament diameter and anechoic region between the CrCL and the bone, ultrasonographic examination is a valuable diagnostic tool as well as cranial drawer test and radiographic examination.

An Empirical Study on the Effects of Public Procurement on the Productivity and Survivability of SMEs: Case of the Korean Mining and Manufacturing Sectors

  • CHANG, WOO HYUN
    • KDI Journal of Economic Policy
    • /
    • v.39 no.1
    • /
    • pp.1-18
    • /
    • 2017
  • This paper empirically studies the effect of public procurement on small and medium-sized enterprises (SMEs) in the Republic of Korea using firm-level data. Public procurement, the purchase of goods and services from private firms by the public sector, is regarded as an important policy measure for providing support to firms, particularly SMEs. This study uses establishment-level panel data of the mining and manufacturing sectors from the Korean National Bureau of Statistics (Statistics Korea) and procurement history from the Korean Public Procurement Service to empirically estimate the effects of public procurement on firms' productivity (total factor productivity) and survivability. Using a propensity score matching estimation method, we find that participating firms showed higher productivity than non-participating ones in the control group only for the year of participation, that is, 2009. After two years, in 2011, they exhibited significantly lower productivity. In contrast, establishments that participated in public procurement for SMEs in 2009 were more likely to survive than those that did not do so in 2011. These results can be interpreted as the negative consequences of government intervention. The market's efficiency enhancement is hindered if underserving companies survive owing to government intervention but fail to improve efficiency.