• Title/Summary/Keyword: Evaluation Procedures

Search Result 1,528, Processing Time 0.031 seconds

Chinese Growth Enterprise Market and Business Performance Analysis on Small and Medium Sized Firms and Venture Firms Before and After Listing (중국의 창업판시장과 중소벤처기업의 상장전후 경영성과 분석에 관한 연구)

  • Cui, Wen;Sun, Zhong Yuan;Chang, Seog Ju
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.9 no.3
    • /
    • pp.129-138
    • /
    • 2014
  • After global economic crisis, China has become one of the two pillars in the global economies and the country contributing to the Korean economy. Nevertheless, the research on Chinese financial market, particularly capital market, is rare to date. This study examined the growth enterprise market that emergedat the Shenzhen stock exchange and made comparative analysis on before and after listing for the Chinese small and medium sized firms and venture firms. The listing requirements at the Chinese growth enterprise market for the technologically innovative venture firms and fast-growing small and medium sized firms with financing purpose were more alleviated than the main board of Shenzhen stock exchange. Moreover, the listing procedures are simplified as well. Accordingly, many Chinese enterprises tend to list and the competition for listing is also intense. In particular, with the 36 initially listed firms at growth enterprise market as the research target, the investigation for the business performance before and after listing reveals that the three indexes including return on common equity, debt ratio and operating profit growth rate dropped dramatically for most all the firms. That is, the profitability and growth for the venture firms and small and medium sized firms listed on the Chinese growth enterprise market decreased rapidly after going public, only the stability improved due to the great financing. Taking a step forward, this phenomenon may result from the exaggerated reporting for the business performance before listing with the purpose of going public by the venture firms and small and medium sized firms. Thus, Chinese Securities Regulatory Commission should strengthen the accounting evaluation standard and regulation for the listing firms before going public. In addition, strict sanctions should be imposed on the firms with fraudulent accounting to establish healthy capital market.

  • PDF

A Study on the Green Ship Design for Ultra Large Container Ship (대형 컨테이너 운반선의 그린쉽 설계에 관한 연구)

  • Kim, Mingyu;Park, Dong-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.558-570
    • /
    • 2015
  • A study on the green ship design for Ultra Large Container Ship (ULCS, 18,000 TEU Class Container Ship) was performed based on the four step procedures of the initial design and hull form optimization to maximize economic and propulsive performance. The first, the design procedure for ULCS was surveyed with economic evaluation considering environmental rules and regulations. The second, the characteristics of single and twin skeg container ships were investigated in view of initial design and performances. The third, the hull form optimization for single and twin skeg ships with the same dimensions was conducted to improve the resistance and propulsive performances at design draught and speed by several variations and the results of the optimization were verified by numerical calculations of CFD and model test. The last, for the estimated operating profile of draught and speed, the hull forms of single and twin sked ships were optimized by CFD. From this study, the methodologies to optimize the hull form of ULCS were proposed with considerations during the green ship design and the improvement of the energy efficiency for the optimized hull forms was confirmed by the proposed formula of the total energy considering design conditions, operating profile and fuel oil consumption.

A Clinical Review of Ectopic Pregnancy (자궁외임신의 임상적 고찰)

  • Hwang, Tai-Young;Nah, Yong-Yun;Kim, Jong-Wook;Park, Wan-Seok;Lee, Tae-Hyung;Lee, Sung-Ho;Chung, Wun-Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.229-235
    • /
    • 1985
  • This study was undertaken for the clinical evaluation and statistical analysis on the 88 women with histopathologically confirmed ectopic pregnancies who were admitted and treated from grand opening on May-28, 1983 to Sept.-30, 1985. Incidence of ectopic pregnancy was 1 in 22.2 deliveries and the most common age group was in 30~34 years of age. There was tendency of decreasing incidencies as the gravidity, panty or artificial abortion were over 3. The most common etiologic factor was pelvic inflammatory disease and procedures for family planning were the next common. Common symptoms were lower abdominal pain (85.2%) and vaginal spotting (56.8%). At the admission, hemoglobin level under 10gm% were 44.3%, 69.5% of urine HCG tests were positive. Culdocentesis was positive only in 75.9%. Termination was frequent at 6 ~ 7 weeks of gestation mostly with rupture or abortion. Free blood in the abdominal cavity was averaged 1,224 ml. 4 cases of clinicobiochemically suspected ectopic pregnancies with spontaneous regression were excluded, and there was no fatal case treated in hospital.

  • PDF

RELAPSE AND STABILITY : AN EVALUATION OF CLASS I MALOCCLUSION NONEXTRACTION THERAPY (비발치로 치료한 제1급 부정교합자의 재귀현상에 관한 연구)

  • Kim, Gu-Soon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.79-89
    • /
    • 1997
  • One of the strenuous problems in orthodontic procedures is postretention stability and retention against relapse. Many investigative trial had been done to disclose the factors associated with relapse and effective prescription to stave off, however, the nature of these jeopardies remained obscure. The objective was to investigate the long-term stability and quantitative changes of dental arches subsequently after Class I nonextraction treatment. Study models,cephalometric headfilms of 26 samples which were taken before, after teatment and postretention were employed to measure the interdental width of corresponding buccal teeth,overbite,overjet and the inclination of incisors and molars. Statistical analysis was carried to compare each measurements across the time period, and followings were brought around. 1. The quantitative amount of relapse in overbite presented positive correlation with the amount of changes through the treatment. 2. Stability of intercanine width was so far secure in the case the expansion had been done through. 3. The amount of changes in intercanine width of the lower regardless of expansion or contraction manifested less than the upper, however, the relapse ratio got high. 4. The upper and lower incisors were likely to be labioversive, and remained stable after retention. 5. The first molars of the upper and lower were conceivably tipped back immediately after treatment and returned to the original angulation. The expansion of intermolar width stayed stable across the time scheme after treatment It was suggested that the maintenance of intercanine width of lower was pertinent to perform the postretention stabilityv and the expansion of dental arch shoed be confined within physiologic boundaries of the patients.

  • PDF

Evaluation on Applicability of the Real-time Prediction Model for Influent Characteristics in Full-scale Sewerage Treatment Plant (하수처리장 유입수 성상 실시간 예측모델 및 활용성 평가)

  • Kim, Youn-Kwon;Kim, Ji-Yeon;Han, In-Sun;Kim, Ju-Hwan;Chae, Soo-Kwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1706-1709
    • /
    • 2010
  • Sewerage Treatment Plants(STPs) are complexes systems in which a range of physical, chemical and biological processes occur. Since Activated Sludge Model(ASM) No.1 was published, a number of new mathematical models for simulating biological processes have been developed. However, these models have disadvantages in cost and simplicity due to the laboriousness and tediousness of their procedures. One of the major difficulties of these mathematical model based tools is that the field-operators mostly don't have the time or the computer-science skills to handle there models, so it mainly remains on experts or special engineers. In order to solve these situations and help the field-operators, the $KM^2BM$(K-water & More-M Mass Balance Model) based on the dynamic-mass balance model was developed. This paper presents $KM^2BM$ as a simulation tools for STPs design and optimization. This model considers the most important microbial behavioral processes taking place in a STPs to maximize potential applicability without increasing neither model parameter estimation nor wastewater characterization efforts.

  • PDF

Evaluation of Accuracy of Modified Equivalent Linear Method (수정된 등가선형해석기법의 정확성 평가)

  • Jeong, Chang-Gyun;Kwak, Dong-Yeop;Park, Duhee;Kim, Kwangkyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.5-20
    • /
    • 2010
  • One-dimensional equivalent linear site response analysis is widely used in practice due to its simplicity, requiring only few input parameters, and low computational cost. The main limitation of the procedure is that it is essentially a linear method, in which the time dependent change in the soil properties cannot be modeled and constant values of shear modulus and damping is used throughout the duration of the analysis. Various forms of modified equivalent linear analyses have been developed to enhance the accuracy of the equivalent linear method by incorporating the dependence of the shear strain with the loading frequency. The methods are identical in that it uses the shear strain Fourier spectrum as the backbone of the analysis, but differ in the method in which the strain Fourier spectrum is smoothed. This study used two domestically measured soil profiles to perform a series of nonlinear, equivalent linear, and modified equivalent linear site response analyses to verify the accuracy of two modified procedures. The results of the analyses indicate that the modified equivalent linear analysis can highly overestimate the amplification of the high frequency components of the ground motion. The degree of overestimation is dependent on the characteristics of the input ground motion. Use of a motion rich in high frequency contents can result in unrealistic response.

Modeling Core Competencies in the Competency-based Nursing Curriculum (역량기반 간호교육과정을 위한 핵심역량 모델링)

  • Kim, Jeong Ah;Ko, Ja-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7635-7647
    • /
    • 2015
  • The purpose of this study is modeling nursing competencies and reasoning out the core competencies, the ability for 20% of important actions for nursing jobs which can manage the rest 80% so that the competency-based nursing curriculum can be developed. A literature review of the vast studies regarding competencies was done to understand the concepts of competency-based curriculum, competency, and nursing competencies, identifying the relationships among each nursing competency categorized in accordance with those concepts. An exemplified concept map of core competencies for the competency-based nursing curriculum is suggested based on a thorough review of various competency modeling methodologies. The core competencies consist of base competency (theoretical/practical nursing knowledge and skills), practical competency (clinical judgment, patient education, communication, etc.), and personality competency (leadership, sense of responsibility, cooperation, etc.). The circular relationship among them can remain consistent through self-directed learning and critical thinking. Therefore, a nurse who have those core competencies is a knowledge worker, a self-directed learner, and also an effective, professional communicator. Further studies which solidify the concept of nursing competencies should be done, as well as the feedback procedures which evaluate the program outcomes and then reflect the evaluation results in the curriculum should be followed continuously.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Implementation of Analysis System for H.323 Traffic (H.323 트래픽 분석 시스템의 개발)

  • Lee Sun-Hun;Chung Kwang-Sue
    • The KIPS Transactions:PartC
    • /
    • v.13C no.4 s.107
    • /
    • pp.471-480
    • /
    • 2006
  • Recently, multimedia communication services, such as video conferencing and voice over IP, have been rapidly spread. H.323 is an international standard that specifies the components, protocols and procedures that provide multimedia communication services of real-time audio, video, and data communications over packet networks, including IP based networks. H.323 is applied to many commercial services because it supports various network environments and has a good performance. But communication services based on H.323 may have some problem because of current network trouble or mis-implementation of H.323. The understanding of this problem is a critical issue because it improves the quality of service and is easy to service maintenance. In this paper, we implement the analysis system for H.323 protocol wihch includes H.245, H.225.0, RTP, RTCP, and so on. Tills system is able to capture, parse, and present the H.323 protocol in real-time. Through the operation test and performance evaluation, we prove that our system is a useful to analyze and understand the problems for communication services based on H.323.

Design Methods for Eccentrically Loaded Bolt Groups for the Single Plate Connections Considering Sloped Edge Distance (편심전단을 받는 단일판접합부의 경사연단거리를 고려한 볼트군의 설계법)

  • Choi, Sun Kyu;Yoo, Jung Han;Park, Jai Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.43-53
    • /
    • 2014
  • A single plate connection(SPC) consists of a plate welded to the columns and bolts connected to the beam web. The SPC is widely used for a simple shear connection of steel structure because it is easy-to-fabricated, easy-to-installed and economical. The conventional SPC is used for 2 to 12 bolts in a single vertical row. It is designed to limit the plate thickness by bolt diameter to obtain flexible and ductile connections. The design strength for eccentric shear shall be the lesser of the shear strength of bolts or bearing strength of plate and when the design strength is decided by edge distance failure, the results can be very conservative. Although the research on special solution for 'weak-plate/strong-bolt' model with 2 to 4 bolts has been conducted by L. S. Muir, and W. A. Thonton, 2004, study on generalized design procedures did not conduct. This study proposed design procedure for evaluation of the design strength of eccentric shear bolt groups on a single plate connection based on the actual edge distance and the direction of bolt reaction forces by using elastic vector method(EVM) and instantaneous center of rotation method(ICM).