• Title/Summary/Keyword: Evaluating System

Search Result 3,173, Processing Time 0.034 seconds

Analysis of Site Condition in Domestic Trade Port for Operation of Mobile Harbor (모바일하버 운영을 위한 국내 무역항 후보지 분석)

  • Lee, Joong-Woo;Gug, Seung-Gi;Jung, Dae-Deug;Yang, Sang-Young;Kim, Tae-Hyung
    • Journal of Navigation and Port Research
    • /
    • v.34 no.10
    • /
    • pp.781-786
    • /
    • 2010
  • In this study, a new concept of ocean transport system, called the mobile harbor serving for a short distance transport of containers with cargo handling cranes between mother containerships and coastal ports, is introduced. Instead of direct berthing a very large containership at the coastal port, Mobile Harbor is moving to the offshore mooring basin with enough water depth condition. Therefore, investigation of the coastal environment, technical condition and limitation of the domestic trade ports for the application of Mobile Harbor, is essential process. To figure out the accessibility of mobile harbor, the environmental conditions, the cargo handling capacity and marine traffic volume and flow pattern has been analyzed with the tools for marine traffic simulation and virtual navigation aids system. The most proper Mobile Harbor mooring areas among trade ports of the south and east coast are selected by analyzing the obtained information and evaluating its application: (1) Under natural environmental conditions such as air and sea weather, three candidate areas are selected such as Masan port, Ulsan port, and Busan(New port) port. (2) Under marine traffic and appropriateness of water facilities, three candidate areas are selected as Mokpo port, Busan(New port) port, and Donghae & Mookho port (3) For a region-based analysis considering handling capacity and the local managed trade ports in vicinity, three candidate areas are selected as Busan region, Yosu & KwangYang region, and Mokpo region. Through this study, the basic guideline for selection of optimum trade port and offshore mooring basin for mothership and Mobile Harbor is recommended. In order to apply the Mobile Harbor to the real water, navigaton aids as the virtual route identification with AIS must be introduced for maritime safety in the vicinity of Mobile Harbor area which berthing and cargo handling is being conducted.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Modification of WASP5 for Ungauged Watershed Management and Its Application (미계측 유역관리를 위한 WASP5 모형의 개선 및 적용성 검토)

  • Kim, Jin-Ho;Shin, Dong-Suk;Kwun, Soon-Kuk
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • This study was carried out to develop a water quality simulation model for the evaluation of an ungauged watershed. For this purpose, the WASP5 model was selected and modified. The model consists of three sub-models, LOAD-M, DYN-M, and EUT-M. LOAD-M, an empirical model, estimates runoff loadings using point and non-point source data of villages. The Geum River Estuary watershed was selected to calibrate and verify the Modified-WASP5. The LOAD-M model was established using field data of water quality and quantity at the gauging stations of the watershed and was applied to the ungauged watersheds, taking the watershed properties into consideration. The result of water quality simulation using Modified-WASP5 shows that the observed average BOD data from Gongju and Ganggyeong were 2.6 mg/L and 2.8 mg/L, and the simulated data were 2.5 mg/L and 2.4 mg/L, respectively. Generally, simulation results were in good agreement with the observed data. This study focused on formulating an integrated model for evaluating ungauged watersheds. Even though simulation results varied slightly due to limited availability of data, the model developed in this study would be a useful tool for the assessment and management of ungauged watersheds.

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment (슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가)

  • Kang, Sung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.219-225
    • /
    • 2016
  • In this study, for assessment of degenerative knee joint cartilage disease we acquired images by fat suppressed 3D spoiled gradient recalled (SPGR) and fat suppressed 3D $T2^*$ weighted imaging techniques. To do a quantitative evaluation, the knee joint cartilage was divided into medial femoral cartilage (MFC), medial tibial cartilage (MTC), lateral femoral cartilage (LFC), lateral femoral cartilage (LFC) and patella cartilage (Pat) to measure their respective signal intensity values, signal-to-noise ratio, and contrast-to-noise ratio. As for the measured values, statistical significance between two techniques was verified by using Mann-Whitney U-Test. To do a qualitative evaluation, two radiologists have examined images by techniques after which image artifact, cartilage surface, tissue contrast, and depiction of lesion distinguishing were evaluated based on 4-point scaling (1: bad, 2: appropriate, 3: good, 4: excellent), and based on the result, statistical significance was verified by using Kappa-value Test. 3.0T MR system and HD T/R 8ch knee array coil were used to acquire images. As a result of a quantitative analysis, based on SNR values measured by using two imaging techniques, MFC, LFC, LTC, and Pat showed statistical significance (p < 0.05), but MTC did not (p > 0.05). As a result of verifying statistical significance for measured CNR value, MFC, LFC, and Pat showed statistical significance (p < 0.05), while MTC and LTC did not show statistical significance (p > 0.05). As a result of a qualitative analysis, by comparing mean values for evaluated image items, 3D $T2^*$ weighted Image has indicated a slightly higher value. As for conformance verification between the two observers by using Kappa-value test, all evaluated items have indicated statistically significant results (p < 0.05). 3D $T2^*$ weighted technique holds a clinical value equal to or superior to 3D SPGR technique with respect to evaluating images, such as distinguishing knee joint cartilages, comparing nearby tissues contrast, and distinguishing lesions.

Factors Influencing Infection Control Awareness and Implementation Levels among Dental Hygienists (치과위생사의 감염관리 인지도와 실천도에 영향을 미치는 요인)

  • Jang, Kyeung-Ae;Park, Jung-Hyun
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.183-192
    • /
    • 2016
  • A total of 228 dental hygienists working in dental hospitals and clinics in the Busan and Gyeongnam areas were surveyed between August 1, 2015, and October 15, 2015. The factors influencing infection control awareness and implementation levels among the dental hygienists were investigated to prepare basic data with the goal of establishing guidelines for systemic infection control. Treatment preparation support for infection control positively correlated with equipment and facility support (r=0.4343, p<0.01), treatment skill and information support (r=0.231, p<0.01), infection control education support (r=0.266, p<0.01), infection control awareness (r=0.354, p<0.01), and infection control implementation levels (r=0.442, p<0.01). Equipment and facility support positively correlated with treatment skill and information support (r=0.418, p<0.01), infection control education support (r=0.422, p<0.01), infection control awareness (r=0.404, p<0.01), and infection control implementation levels (r=0.454, p<0.01). Infection control education support positively correlated with infection control awareness (r=0.348, p<0.01) and infection control implementation levels (r=0.405, p<0.01). Infection control awareness positively correlated with the infection control implementation level (r=0.879, p<0.01). The factors influencing the awareness of infection control include treatment preparation support, equipment and facility support, treatment skill and information support, and infection control education support. The influencing the infection control implementation level include treatment preparation support, equipment and facility support, infection control education support, and treatment skill and information support. To enhance the awareness of infection control and implementation levels amongdental hygienists, an infection control system must be established and implemented A rigorous system for evaluating dental clinics must also be established to ensure an ideal dental treatment environment and to protect patients' health and safety.

Developing National Science Assessment System:Scientific Knowledge Domain (국가 수준의 과학 지식 평가 체제 개발)

  • Kwon, Jae-Sool;Choi, Byung-Soon;Kim, Chan-Jong
    • Journal of The Korean Association For Science Education
    • /
    • v.18 no.4
    • /
    • pp.601-615
    • /
    • 1998
  • Establishing and evaluating science education policies and revising and monitoring the effectiveness of science curriculum should be based upon the results of systematic and scientific research studies. Advanced nations have already been administering and developing national level science assessments for these purposes. The science assessments administered in Korea have been reported having many limitations and problems, and not succeeded in providing data for science education policy making and curriculum reform. The major purpose of the study is developing national level science knowledge assessment system in order to identify longitudinal trends of elementary and secondary school students science knowledge achievements. The research team consisted of science education experts and teachers from various school levels, decided the directions and major elements of national level science knowledge assessment with the consultation of educational evaluation experts. Item developing ability of the researchers was improved by seminars? and workshops on national assessment in advanced nations and developing skills of writing science items. Nearly 500 items were developed and revised. Pilot test was administered with 958 students at various school levels. 380 items were selected and tested with 8766 students, and the characteristics were analyzed in terms of item response theory. The target populations for national level science knowledge assessment are 5th-grade of elementary school, 2nd-grade of middle school, 1st and 2nd-grade of high school students. The proper period for the assessment is February every year. Multi-stage clustered sampling method is desirable and rotated forms are recommendable for the test format. Bridge items should be introduced to compare the results of multiple tests, and various grades. Anchor items should also be used for longitudinal interpretations of the results. The items for elementary school require low to medium abilities, for middle school and first grade of high school require medium to high abilities and for 2nd-grade of high school high abilities. The discrimination ability of the items developed is high.

  • PDF

Evaluating the Appropriateness of the Forest Program in the Special Account for Balanced National Development - With a Focus on the Recognition of Local Government Officials in Forest sector - (국가균형발전특별회계(國家均衡發展特別會計) 대상(對象) 산림사업(山林事業)의 적정성(適正性) 평가(評價) - 지방자치단체 산림공무원의 인식을 중심으로 -)

  • Bae, Jae-soo;Park, Sang-mi;Song, Young-gun;Park, Keong-seok;Kim, Se-bin;Kwak, Kyung-ho
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.680-689
    • /
    • 2006
  • Introduction of the Special Account for Balanced National Development (SABND) which was represented top-down in 2005 have previous national budget distribution system between central and local government change. A local autonomous entities can choose freely the favorite programs within the total programs in SABND so they can use limited budget efficiently, After induction of this system, budget of the Forest Programs in SABND in 2006 compare to last year has increased by 24.5 percent. That is three times higher than the average rate of total SABND budget, 8.1 percent. This study surveyed propriety of the Forest Programs and hereafter their budget prospect with local government officials in forest sector, 68.7 percent of the respondents recognized that the inclusion of the Forest Programs in SABND is proper. The most preferred Forest Programs are making Urban Forests and their Management and making Facilities for Forest Recreation. And the most non-preferred Forest Programs are complementing the Lumberyard Facility of the Forestry Association, making the Exhibition of Wood Products and making the Base for the Seedling Production. When Forest Programs are adjusted in the future, these programs above mentioned should be exempted from the SABND. because the non-preferred programs as well as the small budget programs On the prospect of the future budget, 81.1 percent of the local government officials in forest sector answered that it will be the same with the current or increasing, In the short term, the budget of the Forest Program in SABND is expected to increase.

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.