Study on the Escape Safety of University Dormitory with the Consideration of Plan Types (대학 기숙사의 평면 형태에 따른 피난 안전성 검토)

  • Jeong, Hyeon-Jae;Jeong, Gun-Sik;Ahn, Young-Chull
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • University dormitory has some weaknesses against disaster such as fire because of high population density and strict control of access in night time. The purpose of this study is suggestion of a guide of effective floor plan for improvement of evacuation safety. Plans for preventing disasters are studied and evacuation safeties are analysed using network model analysis method according to plan types. The weakness of disaster prevention is quantified, and effectiveness of bidirectional evacuation is confirmed. The circuit type floor plan shows best evacuation characteristics and this result is anticipated to be adopted to design process of new dormitories and will contribute to improvement of evacuation safety.

Analysis of RSET According to Exit Installation Standards for the Exterior of a Food Manufacturing Plant Building (식품공장 건축물 바깥쪽으로의 출구 설치기준에 따른 RSET 분석)

  • Park, Ha-Soung;Lee, Jae-Wook;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.201-208
    • /
    • 2024
  • In this study, we investigated whether the evacuation time according to the exit installation standards specified in the building code during a food factory fire is compatible with the evacuation time based on the performance-based design specified by the fire department, in order to determine if evacuation safety is ensured. We used the Pathfinder program to confirm the evacuation time, and experimented with three scenarios for exit installation standards towards the outside of the building: 60m, 80m, and 100m. The target building in the experiment corresponded to the building code's exit installation standard of 100m from each dwelling. The experimental results showed tt in the cases of 80m and 100m, ASET exceeded RSET, indicating tt evacuation safety was not ensured, while in the case of 60m, evacuation safety was maintained. Through this study, it was confirmed tt even when the exit installation standards towards the outside of the building are met, evacuation safety may not be guaranteed.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

A Study on Analysis of Passenger Safety in Railroad Tunnel Fire - Using Simulation - (시뮬레이션을 이용한 철도터널 화재 사고의 승객 안전도 분석)

  • Kim, Dong-Jin;Moon, Seong-Am;Kim, Dong-Gun;Kim, Kyung-Sup;Jang, Young-Joon;Jung, Woo-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, the methodology to predict the number of deaths and possible fire propagation scenarios will be described in case of fire on a train in a tunnel. We use a probabilistic analysis method for the evaluation of possibility for each scenario and the deaths tolls are calculated with the help of the passenger evacuation simulation program. The resulting safety of passengers is displayed on a F/N graph, which could be used in part as a guideline to predict the safety level of the tunnel in fire.

A Study on the Evaluation the Safety of Evacuation in Indoor Sports Stadium through Evacuation Simulation (피난시뮬레이션을 통한 실내 스포츠경기장 내 장애인의 피난 안전성 평가 연구)

  • MinEon Ju;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • Purpose: Recently, there has been a movement to guarantee the right to watch sports for the disabled. However, the sports stadium is designed without considering the wheelchair users, so the right to move in the stadium is not secured. Restrictions on the movement of the disabled make the evacuation vulnerable in an emergency. This study aims to develop a plan to ensure the safety of movement and evacuation of wheelchair users by conducting simulations targeting indoor sports stadiums. Method: The simulation was performed by constructing a scenario with the shape of the stands as a variable. The effect of the installation of wheelchair seats on evacuation was confirmed. Result: The results according to whether wheelchair seats are installed, the evacuation route of wheelchair movement, and whether wheelchair seats are separately arranged were compared. The impact of wheelchair seat installation on evacuation and its characteristics were derived. As a result, upward and separation seat was the most vulnerable to evacuation. Conclusion: A plan to secure evacuation performance was derived for the top floors of upward and separation seat. It is judged that the content can be use as a way to secure the safety of movement and evacuation of the disabled in sports stadiums.

An Application of Evacuation Model for Rail Passenger Car (철도차량에 대한 피난모델 적용)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.123-128
    • /
    • 2007
  • To predict the fire and smoke hazards of rail car with a evacuation model is essential for achieving life safety of all passengers in the event of fire. Currently, more than 30 different evacuation models are available and expected increasing demand in high population density areas as a metro train station. This paper includes brief history of evacuation models and review some key factors of design egress scenario, these are pre-movement time, egress route, location of fire, overturned carriage, and configuration of rail car. Applying the egress model for rail passenger car, users need to confirm the model's ability of physiological, psychological responses effecting to pre-movement time of individual or crowd unit, representation of complexity of carriage layout, and evaluation of effects of smoke.

  • PDF

Improved Plan for Evacuation of Residents in Landslide-Prone Rural Area (산사태 대비 농촌 주민 대피계획 개선 방안)

  • Kim, Jungmeyon;Park, Sungyong;Lim, Changsu;Yeon, Kyuseok;Kim, Yongseong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • This study has purpose on deducting problems of evacuation plan for vulnerable populations in disaster and suggesting improvement plan through analysis of disaster weakness in domestic rural region aiming at vulnerable populations in disaster like old people containing most of domestic rural population, sometimes being in blind spot of safety when landslide or disaster occur. As a result, we could know that rural regions have high proportion of vulnerable populations in disaster like old people, also being so weak to landslide and slope collapse. So we suggested development of manual describing prevention of disaster and evacuation for vulnerable populations in disaster like old people and disaster evacuation organization for house and minimizing solution for damage of human life through improvement of steep slope evaluation criteria.

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.