• Title/Summary/Keyword: Evacuation safety evaluation

Search Result 88, Processing Time 0.019 seconds

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.

An Evaluation on Evacuation Safety in Training Facilities For Young People based on Fire and Evacuation Simulation (화재.피난 시뮬레이션을 통한 청소년 수련관 시설의 피난 안정성 검토)

  • Chol, Chang-Ho;Cho, Mm-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.23-32
    • /
    • 2009
  • The Purpose for this study was to analyze the evacuation behavior of a training facilities for young people in case of fire emergency. It is necessary to study for fire safety design of the training facilities. The study carried out two different simulations on the training facilities. The results were divided into two groups by using Simulex, FDS. By comparing those two different outputs, we were able to verify the problems of existing training facilities. The results have shown that there was a need for a greater structural design in these training facilities.

Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage (아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital (일개 노인요양병원의 피난안전성능 평가에 관한 연구)

  • Kim, Jong-Bum;Kim, Ja-Ok;Back, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.9-19
    • /
    • 2010
  • Recently, Korea is constantly increasing its elderly care hospitals, and requires establishment of general evacuation plan considering old people's behavioral characteristics and physical states in emergency situations such as fire, and etc. In addition, because most of the facility users are patients under serious dementia and stroke, they feel difficulty evacuating by themselves, with differing evacuation time according to each walking status (bed, wheel chair, and various supplementary instruments), which is why it makes it difficult to have them all evacuate. This paper, in order to suggest data reference for designing on the basis of functionality, used various collected data utilizing Simulex to measure evacuation time through the model of elderly care hospital, a medical facility. During the study, several problems were found.

A Study on Evacuee′s Risk Assessment under Ship′s Fire (선박화재의 인명안전평가 해석)

  • 양영순;정정호;이재옥;공수철;여인철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.241-247
    • /
    • 2001
  • A Fire Safety Evaluation Module(FSEM), which quantitatively evaluates the risk of evacuees when fire occurs in buildings or ships, is presented in this paper. The developed FSEM can be applied to multi-room structure. Basic input data for the FSEM are prepared by fire model and evacuation model. CFAST which is one of the existing fire models is used as fire model and MonteDEM evacuation model was developed for evacuation model, respectively. MonteDEM evacuation model makes use of distinct element method and Monte-Carlo simulation, and it can also take into consideration ground inclination by ship motions in order to simulate the real situation of evacuation. Some typical situations are modelled for illustrative examples and quantitative assessment of evacuee's risk under fire accident is carried out.

  • PDF

Study for Using VR Techniques Performance Evaluation of the Elevator Evacuation (VR기법을 활용한 엘리베이터 피난 성능평가에 관한 연구)

  • Ro, Se-Ho;Yoon, Sung-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.13-18
    • /
    • 2011
  • In the disaster prevention design, it is important point to secure escape way at event of fire which makes people away from the fire more quickly and safely. Development of construction techniques leads to build many skyscrapers, and skyscrapers contains various dangers and increase levels of disaster. At basic design stage for skyscrapers, evacuation scenario is considered that occupants are escape using escape stairs and emergency elevators simultaneously at fire, but there is no evacuation program to simulate using escape stairs and emergency elevators at the same time. In this study, evacuation simulation is performed using method of VR which is based on Virtools of 3DVIA Co., and Simulex of IES Co. for safety and effectiveness where occupants are escape using escape stairs and emergency elevators simultaneously at the fire.

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.