• Title/Summary/Keyword: Evacuation equipment

Search Result 67, Processing Time 0.029 seconds

A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment (정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구)

  • Lee, Bo-Hoon;Hong, Seo-Hee;Baek, Doo-San;Lee, Ho-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.539-552
    • /
    • 2022
  • In the case of train stations, due to the specificity of underground spaces with limited smoke emissions, if appropriate removal equipment is not equipped, the damage caused by fire smoke may increase in the event of a fire. As a result, the need for measures to ensure the safety of evacuation of underground stations has been highlighted, and research for safe evacuation of platform users in case of fire is continuously being conducted at home and abroad. However, although the smoke removal area is currently divided by smoke boundary walls and platform screen doors (PSD) and installed in the train platform, standards for smoke removal methods (air supply or exhaust) for each fire removal area, that is, smoke removal mode, are not presented. In this study, fire analysis and evacuation analysis were performed to estimate the number of deaths and to derive F/N guidance in order to quantitatively evaluate the fire risk according to the fire station fire, and the total risk was the lowest in the case of fire area exhaust and supply to adjacent areas.

Study on Verification of Applicability for a Warehouse Construction Site using a Fire Risk Assessment Tool (화재위험도 평가 Tool에 의한 물류창고 공사장 적용성 검증에 관한 연구)

  • YongGoo Seo;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.673-688
    • /
    • 2023
  • Purpose: Fires that occur during construction are infrequent, but cause great damage. Recently, with the growth of the logistics and distribution industry, the number of construction sites for new logistics warehouses is increasing, so it was selected as a research subject and research was conducted to reduce accidents at construction sites through the development of a fire risk assessment tool to quantitatively approach fire prevention. Method: A comprehensive fire risk assessment tool was accumulated by classifying the work in progress, classifying combustibles and ignition sources by grade, excluding air (oxygen), which is difficult to control, and additionally substituting evacuation safety. Result: Using the developed and proposed fire risk evaluation tool, excavation work with low fire risk, facility construction with medium fire risk, and finishing work with high fire risk were sampled to derive the result (CGI). Conclusion: In this study, it was possible to establish specific preventive measures and evaluate evacuation safety by controlling physical conditions (combustibles) and energy conditions (ignition sources) according to the risk assessment by developing a tool that can evaluate the risk of 14fire occurrence at construction sites. It is expected that in the future, through the application of the fire risk evaluation tool at construction sites, it will be provided as a criterion for establishing a process plan that can reduce risk and evaluating the adaptability of firefighting equipment.14

A preparation and Strategy against Chemical and Biological Terrorism (화생방 테러의 양상과 예방대책)

  • Kim, Kyung-Hoe
    • Korean Security Journal
    • /
    • no.5
    • /
    • pp.19-40
    • /
    • 2002
  • For front, aspect of terror may have to prepare indeed even chemical terror or rocket and small size missile and radioactivity terror because is predicted to become various. Furthermore, when see motion of every countries about nuclear engineerses' bringing round and illicit sale of plutonium, our country may have to prepare in terrorism which is expected thus. So that can finish international event successfully because the United States of America supports great manpower and budget since New York's World Trade Center terror and when see that is considering terror prevention countermeasure, we operate temporarily bursting tube state complete charge team such as terror by each field specialist such as a concern interested including special CBR complete charge moving team among 2002 World Cups soccer game period ahead of international event, must consider safety countermeasure. Specially, biology weapon of chemical weapon and cholera etc. 13 kinds of 5000ton that North Korea plans CBR terror society confusion that North Korea that to terror support nation as well as nuclear weapons development suspicion is defending South Korea communization strategy as real condition that is amplified as well as is saving production brand gets imprinted uses CBR terror at normal times, when see that is planing powerlessness communization unity using CBR weapon at time of war, must operate until bias 2002 World Cups international event finishes cooperation safety countermeasure utensil safely under closer talk between the South Korea ${\cdot}$ Japan ${\cdot}$ North Korea. As for us which must serve 2002 World Cup successfully to accomplish perfectly preparedness of CBR terror firstly, all inhabitants knows well CBR protection trick, and secondly, CBR existing formation that solidify realignment CBR complete charge moving team which of course is consisted of CBR specialist compose and keeping immediate going out attitude operating, by third, that expand CBR individual protection equipment and CBR evacuation equipment and establish individual and group protection attitude naturally, supplement as there is main room that actualize CBR pollution patient's slogan countermeasure by fourth, and develop standard model for CBR terror provision by fifthBecause constructing infra of CBR safety establishing CBR preparedness that utilize it, must minimize damage and contribute inhabitants' life and property protection.

  • PDF

Study on KOLAS Certification Approach for Radiation Protection Products - Focusing on Masks (방사능 방호 제품에 대한 KOLAS 인증 방안 연구 - 마스크를 중심으로)

  • Namhee Park;Wookhyun Yeo;Sungjin Hong
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.815-825
    • /
    • 2023
  • Purpose: This paper aims to explore approaches for obtaining KOLAS certification for masks developed as protective equipment for use during evacuation processes in the event of a radiation disaster involving residents within a radiation emergency planning zone. Method: Various reports, papers, and data from the KOLAS accreditation bodies' websites were examined for this study. Result: Although domestic radiation disaster preparedness measures have been established to enhance resident protection, the distribution of protective equipment is limited to thyroid protection drugs. Supplementary support items like masks are necessary to prepare for radiation disasters. Currently, there is no KOLAS-accredited certification body for radiation protection masks. Conclusion: For masks that have established performance certification criteria, a dual process is required for KOLAS certification. This involves obtaining an official test report as an industrial respirator mask, receiving certification, and then obtaining a general test report based on internal standards.

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.

A Study on the Functional Fraction of the Bathroom Space in Apartment (아파트 욕실의 기능적 공간분리 연구)

  • Hwang, Sung-Won;Kim, Hye-Jung;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.156-159
    • /
    • 2007
  • Bathroom in apartment has the main functions of bath, washing hand and evacuation. The bathroom equipments for these functions are bathtub, shower booth, washbasin and toilet stool. Generally, these equipment are put together in one space, so it may cause people have trouble in using bathroom by other family members' occupation. Therefore the purpose of this study is to investigate the degree of preference about bathroom space fraction and grope for the connection with other spaces in apartment. The subject of this study were residents who live in brand apartments located in Seoul. The survey were carried out from november to December 2006. The data were analyzed through SPSS/PC+ using frequency, percentage and crossovers. The results of this study are as following, 1. A number of respondents would have trouble in using the bathroom by other family members' occupation once a week or more. The functional fraction of bathroom space is needed. 2. Close adjacency to Powder space, dress room is preferred. Coordination of washbasin and powder space is also needed. 3. Each separated spaces can be connected with other related spaces.

  • PDF

A Study of Emergency Response for the Leakage Accident of Hazardous and Noxious Substances in a Port (항만에서의 위험·유해물질(HNS) 누출사고 대응에 관한 연구)

  • Woo, Young Jin;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.32-38
    • /
    • 2016
  • In general, lots of containers including various dangerous materials are transported to the port located in big cities such as Busan where massive residents live. Thus, it's really important how to make the emergency response for the leak accidents of dangerous materials and evaluate the direct or indirect damages to adjacent areas. In this study, in order to make reasonable emergency plans, CA (Consequence Analysis) is employed after selecting a key hazardous and noxious material, hydrogen fluroide. This material accounts for the third largest portion of cargo volume among all dangerous materials and can cause a huge damage in case of leakages. As a case study, Busan North port is selected as a test port since the portion of dangerous materials is higher than that of other ports in Busan. It is assumed that 1 ton of hydrogen fluoride is spilled at Busan North port. CA is performed to assess the impact of this accident. Throughout CA, the ERPG-2 range of a leak accident can be evaluated and this result can be used for decision making tools for mitigating the impact of a leak accident. To mitigate the damage of this accident, suitable a protective equipment and resident evacuation procedures should be prepared. Finally, this study can provide a systematic approach to make the emergency plan for reducing economical and personal losses.

A study on the Computer-Aided Design of steam ejector (증기 이젝터의 자동설계를 위한 전산프로그램의 개발)

  • 김경근;김용모;강신돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.53-60
    • /
    • 1987
  • Steam ejector is a equipment which compresses the gases to desired discharge pressure. It is widely used for the evacuation systems because of its high working confidence. And recently it is used as the thermo-compressors in the various energy saving systems. Steam ejector is constructed of three basic parts; a suction chamber, a motive nozzle and a diffuser. The high velocity stream jet of steam emitted by the motive nozzle creats suction chamber, which draws the low pressure gases. The diffuser converts the kinetic energy of high velocity flow to pressure energy. It is not easy to determine the dimensions of a steam ejector met to the desired design condition, because that the expected suction rates must be obtained by reapeating the complicate calculation. And also such a calculation is concomitant with geometrical analysis for suction part and diffuser based on the stability of steam flow. Therefore, it is considered that the Computer-Aided Design (CAD) of steam ejector is a powerful design method. In this paper, computer program for steam ejector design is developed based on the theoretical research and the previous experimental results. And the determinating method of diffuser inlet angle and the velocity development profile of suction gas along to the diffuser are suggested. The validity of the development profile of suction gas along to the diffuser are suggested. The validity of the developed computer results with other's for the practical design calculation of a manufactured steam ejector.

  • PDF

Categorizing Safety Management Elements for Fire Preparation and Assessemnt of Fire Hazard (화재에 대비한 지하공간의 안전관리 요소분류 및 화재위험성 평가방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.96-109
    • /
    • 2011
  • In this study, risk categorized five safety management elements(equipment and structure, evacuation, lifesaving and fire extinguishing, performance based fire safety plan, operations management) were classified in order to establish safety system of underground space. Using classified safety management elements, assessment of fire hazard was performed. After calculating the grade of evaluation categories, assessment of fire hazard was suggested. The three grades of evaluation categories are classified as to importance and four criteria of evaluation are classified as to check result based on subdivisions.

The Selter Selection Plan due to Formaldehyde Leakage (포름알데히드 누출에 따른 대피장소 선정 방안)

  • SeungJu Oh;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.117-129
    • /
    • 2023
  • This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.