• Title/Summary/Keyword: Evacuation Route

Search Result 139, Processing Time 0.025 seconds

Smart Escape Support System for Passenger Ship : Active Dynamic Signage & Real-time Escape Routing (능동형 피난유도기기와 실시간 피난경로생성 기술을 적용한 여객선 스마트 인명대피 시스템)

  • Choi, James;Yang, Chan-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.79-85
    • /
    • 2017
  • It is critical that passengers should be given timely and correct escape or evacuation guidance from captain and crews when there are hazardous situations in a ship. Otherwise the consequences could be disastrous as "SEWOL Ferry" the South Korean passenger ship which sank in southern coastal area on 16th April 2014. Due to the captain's delayed evacuation decision and lack of sufficient number of crews to guide passengers' evacuation, the accident recorded many casualties, most of whom were high school students (302 passengers sank down with the ship while 172 rescued). Building a passenger ship with well-designed physical escape routes is one thing and guiding passengers to those escape routes in real disaster situation is another. Passengers get panic and move to a wrong direction, bottleneck makes situation worse, and even crews get panic also - passive static escape route signage and small number of trained crews might not be enough to take care of them. SESS (Smart Escape Support System) is being developed sponsored by South Korea Ministry of Ocean and Fisheries starting from 2016 with 4 years of roadmap. SESS comprises multiple active dynamic signage devices which communicate with real-time escape routing server software via LoRa (Long Range) proprietary wireless network.

  • PDF

Implementation of virtual reality for interactive disaster evacuation training using close-range image information (근거리 영상정보를 활용한 실감형 재난재해 대피 훈련 가상 현실 구현)

  • KIM, Du-Young;HUH, Jung-Rim;LEE, Jin-Duk;BHANG, Kon-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.1
    • /
    • pp.140-153
    • /
    • 2019
  • Cloase-range image information from drones and ground-based camera has been frequently used in the field of disaster mitigation with 3D modeling and mapping. In addition, the utilization of virtual reality(VR) is being increased by implementing realistic 3D models with the VR technology simulating disaster circumstances in large scale. In this paper, we created a VR training program by extracting realistic 3D models from close-range images from unmanned aircraft and digital camera on hand and observed several issues occurring during the implementation and the effectiveness in the case of a VR application in training for disaster mitigation. First of all, we built up a scenario of disaster and created 3D models after image processing with the close-range imagery. The 3D models were imported into Unity, a software for creation of augmented/virtual reality, as a background for android-based mobile phones and VR environment was created with C#-based script language. The generated virtual reality includes a scenario in which the trainer moves to a safe place along the evacuation route in the event of a disaster, and it was considered that the successful training can be obtained with virtual reality. In addition, the training through the virtual reality has advantages relative to actual evacuation training in terms of cost, space and time efficiencies.

Service Scenario Development for Customized Evacuation Route Guidance Service in Regular Building (일반건물 맞춤형 대피동선 안내 서비스를 위한 서비스 시나리오 개발 사례연구)

  • Kim, Tae Wan;Lee, Sang Ki;Shin, Dong Min;Lee, Sung Pil
    • Journal of Service Research and Studies
    • /
    • v.8 no.4
    • /
    • pp.13-29
    • /
    • 2018
  • The final goal of this study was to develop an optimal service scenario to ensure that building occupants can be effectively evacuated from the building within the golden time without extra assistance in preparing and evacuating for fires. In addition, the research was carried out by dividing the current services into fire evacuation and preparedness phases by applying the Double Diamond process in order to find a way to better familiar them as a lifestyle and to always be prepared for fires. For the building occupants and managers, a total of 14 ideas were first suggested, including not only the services of how to evacuate from a fire, but also the life-style service functions associated with fire implementation technology in daily life. The 14 proposed ideas were conducted by the Service quality evaluation and Analytical Hierarchy Process(AHP) from the perspective of the service recipient, and those were finally prioritized from the service provider's perspective, taking into account the cost and practicality of the service provider. The results of this study show that differences in the importance of fire phases considered by stakeholders and the perception of fire generally vary considerably.

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

Proposal of safe fire escape system for the day-care center and the kindergarten (어린이집 및 유치원의 화재 대피용 안전 경로 시스템 제안)

  • Choi, Jun-Ho;Kwon, Mee-Rhan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.297-301
    • /
    • 2015
  • Day-care centers and kindergartens are increasing along with the damage caused by fire year after year. Infants and toddlers have a low response capability than adults to fire situations such as heavy smoke which causes less or zero visibility thus it is difficult in evacuation route during dangerous fire situations. Because of these circumstances, teachers need to build a safe pathway signage system along with the usual fire safety training needs of infants and children. In this paper, we propose a system for fire escape which marks the escape routes and are automatically implemented through the push function that smartphone recognizes during the real-time fire situation, and establish a system that verifies its authenticity.

A Study on Technology Commercialization of Indoor Floor Advertising Lighting Devices Applicable to Advertisements and Disaster Situations (광고 및 재난상황에 적용 가능한 실내용 바닥광고 조명장치의 기술사업화 방안 연구)

  • Kwang-Soo Kim;Woon-Seek Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.32-40
    • /
    • 2023
  • Recently, there are some outdoor floor advertising lighting devices as one of the active marketing methods. However, for outdoor use, there are many restrictions due to the Outdoor Advertisement Act, according to requiring high-output heat generation, waterproofing, and AC power, etc. The purpose of this study is to develop a Duo Light product optimized for indoor use through publicity and information guidance in normal times and automatic evacuation route guidance display in case of disaster, in conjunction with disaster safety. To that end, patent search and patent association analyses were conducted, and a comparative analysis with commercial products was conducted as a case study. In addition, prototypes were designed and produced through the review of operation principles, where field environment surveys and self-tests were conducted. Also, technology roadmaps were presented by preparing plans for expandability and advancement of products. For the analysis of technology commercialization, the feasibility of technology commercialization was examined through the analysis of Jolly's Model and Lean Canvas Model. The results of this study will be able to contribute to minimize human damage through the effective response to disasters, which can increase the effect of indoor advertising by using the proposed indoor floor advertising lighting device in advertising and disaster situations.

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Vestibule pressurization system should produce uniform air egress velocity to prevent the intrusion of smoke into escape route when fire accidents occur inside a building and fire doors are open for evacuation of people. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where two doors are installed varying the location of a damper and louver angle. From simulations, we found that when the damper in the vestibule is located at the center of the wall opposite to two fire doors, the uniform air egress velocity can be obtained.