• Title/Summary/Keyword: Evacuation Characteristics

검색결과 212건 처리시간 0.035초

Simulation of outgassing effects of vacuum materials on vacuum characteristics

  • Kim, Hyung-Taek;Kim, Young-Suk
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2009
  • The outgassing effects of selected vacuum materials on the vacuum characteristics were simulated by the $VacSim^{Multi}$ simulation tool. This investigation examined the feasibility of reliably simulating the outgassing characteristics of common vacuum chamber materials (aluminum, copper, stainless steel, nickel plated steel, Viton A). The optimum design factors for these vacuum systems were suggested based on the simulation results. The baking-out effects of the modeled systems and materials on the performance of the vacuum system were also analyzed. The simulation predicted that the overall outgassing effect was more significant in the TMP system than in the DP system and that the utilization of a booster pump has a greater effect on the evacuation time than on the ultimate pressure.

  • PDF

수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석 (Numerical analysis on effect of hole size on Emergency Evacuation Support System)

  • 김지태;박원희;이덕희;노경철
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.324-329
    • /
    • 2020
  • 비상피난 지원시스템은 화재 발생시 차연막이 형성되고 차연막 내부로 외기를 급기 가압을 해주어 연기의 유입을 막아주어 안전한 대피로를 제공한다. 본 연구에서는 수치해석을 통해 급기구 지름이 10, 15, 20, 30 mm로 변화 할 때 비상피난 지원시스템 차연막 내부에 급기구 크기가 유동에 미치는 영향을 분석하였다. 그 결과 급기구 지름이 감소할수록 비상피난지원 시스템 입구부터 출구 길이 방향으로 급기구를 통한 유량이 비교적 고르게 형성 되는 양상을 보였다. 또한 20 mm 이상으로 급기구를 타공 할 경우 출구부 근처에는 급기 유량이 거의 발생하지 않는 문제점이 발생 하므로 급기구 지름을 20 mm 보다 작게 타공 해야 할 것으로 판단된다. 차연막 내부 공간 압력은 20 mm 이하로 타공시 길이 방향으로 비교적 매우 균일한 분포를 보였다. 또한 수치해석 결과를 이용하여 급기구의 부차 손실계수을 산출 하였으며 약 K=1.5 으로 계산되었다. 따라서 향후 비상피난 지원 시스템 설계시 본 연구에서 도출한 급기구 지름에 따른 유동특성과 급기구의 부차손실을 적용하여 적절한 설계가 수행될 수 있을 것으로 판단된다.

보행류 기반 도시철도역사 평가 시뮬레이터를 활용한 대피 시나리오 분석 (An Analysis on Evacuation Scenario at Metro-stations using Pedestrian Movement-based Simulation Model)

  • 유소영;정래혁;정진혁
    • 한국ITS학회 논문지
    • /
    • 제15권2호
    • /
    • pp.36-49
    • /
    • 2016
  • 도시 철도는 도시 광역권 교통수단으로, 주요 노선들이 만나는 환승역사의 경우, 역사내 보행 통행시 극심한 혼잡을 야기하며, 승강장 내 교통약자를 포함한 이용객들의 안전사고 위험이 높게 나타난다. 반영구적 도시교통 기반시설로의 도시철도역사는 초기 건설 당시 장기 이용 수요 예측을 실시하지만, 향후 신설 노선 및 환승(예정)역을 정확히 파악할 수 없고 건설완료 이후 토지이용계획이 급변할 경우, 예측 수요와 실제 수요는 상이하게 나타날 수 있으며, 확장이 제한적이고 대규모 추가공사 비용이 요구되기 때문에 도시철도 역사가 지닌 물리적 특성 및 이용자 요구에 따라 효율적인 개선이 필요하다. 본 연구에서는 도시철도역사 구조, 이동 동선 등 물리적 요소와 시시각각 변하는 도시철도 내 이용수요 등 변수를 고려하여 다양한 시나리오에 대한 효과분석이 가능한 도시철도역사 평가용 시뮬레이터 핵심 모형을 소개하고, 해당 시뮬레이터를 활용하여, 사당역 대피 시나리오를 분석하였다. 분석결과, 시뮬레이터 활용하여 유사상황 발생시 입체 공간 상에서 다양한 조건을 고려한 다수의 대피 경로 탐색이 용이하였으며, 사당역의 경우, 대피경로 정보제공을 통해 기존 대비 약 60% 대피시간을 절감할 수 있는 것으로 분석되었다.

시뮬레이션을 이용한 플랜트 시설물 제연설비에 관한 연구 (A Study on the Smoke Removal Equipment in Plant Facilities Using Simulation)

  • 최두찬;양민혁;고민혁;오수민
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2024
  • 연구목적: 본 연구는 플랜트 시설물의 피난 안전성을 확보하기 위해 제연경계벽의 폭 및 제연설비의 유무와 피난 안전성과의 관계를 분석하고자 한다. 연구방법: 화재 및 피난 시뮬레이션을 활용하여 제연경계 벽의 폭, 수직거리에 따른 급기량, 배기량의 변화를 통해 피난 안전성을 분석 하였다. 연구결과: 가시도의 경우 경계벽 0.6m 만을 사용한 경우 5m 이하로 되는 시점이 가장 짧게 도달하였으며 제연경계 폭 1.2m와 제연설비를 사용한 경우와 비교하여 20%긴 것으로 나타났다. 온도의 경우 제연설비를 사용하지 않고 경계 폭만 사용하였을 때 0.6m 보다 1.2m가 20% 긴 것으로 확인되었다. 결론: 제연 경계벽에서는 온도를, 제연설비에서는 가시도의 영향을 줄일 수 있으나, 반대로 제연 경계벽의 길이를 길게 하였을 때 가시도의 영향을 줄 수 있으며, 제연설비를 설치하였을 때 온도의 영향을 주는 것으로 나타났다. 따라서, 공정 특성을 고려하여 적합한 제연계획과 제연 설비를 설치해야 할 것으로 판단된다.

Analysis of High Vacuum System Based on the Applications of Vacuum Materials

  • Kim, Hyung-Taek
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.334-338
    • /
    • 2013
  • In this study, the outgassing effects of selected vacuum materials on the vacuum characteristics were simulated by the $VacSim^{Multi}$ simulation tool. This investigation examined the feasibility of reliably simulating the outgassing characteristics of common vacuum chamber materials (aluminum, copper, stainless steel, nickel plated steel, Viton A). The optimum design factors for these vacuum systems were suggested based on the simulation results. The baking-out effects of the modeled systems and materials on the performance of the vacuum system were also analyzed. The simulation predicted that the overall outgassing effect was more significant in the turbomolecular pump system than in the diffusion pump system and that the utilization of a booster pump has a greater effect on the evacuation time than on the ultimate pressure.

신체특성과 재실자밀도를 고려한 국내외 피난안전규정 비교연구 (A Comparison Study on the International Egress Safety Standards Considering the Physical Characteristics and Occupant Density)

  • 김동은;서동구;황은경;황금숙;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Recently with the increasing economics, many hish-rise and complicated building with new architecture features are constructed in Korea. These tall and big building have many difficulties of fire safety concerns, especially evacuation plan. so, If a fire breaks out in big shopping center in the super tall building, how should the occupants evacuate? In the side of this evacuate problem of big shopping center, It is the aim of this study to compare and analyze the difference between America and Korea. Considering the Physical Characteristics and Occupant Density.

  • PDF

PDP용 격벽재의 승온 탈가스 특성 (Characteristics of Outgas from Heated Barrier Rib for POP)

  • 김선호;주정훈;이석영;이강욱;오상진
    • 한국표면공학회지
    • /
    • 제37권3호
    • /
    • pp.185-190
    • /
    • 2004
  • Plasma Display Panel is a display device emitting fluorescent light from gas discharge between a front and a rear panel sealed together. Front and rear panel have multitude of film layers and barrier ribs in the rear panel has the largest area so releasing various gases and affecting light emitting characteristics and lifetime. The remaining gases in a barrier rib were studied by thermal desorption analysis up to $400^{\circ}C$ and main gases were $H_2$ $H_2$O, CO. During sustaining at $300^{\circ}C$, the outgassing rates from other gases were decreased but$ H_2$ kept constantly increasing until 1 hour, which can be originated from the dissociation of organics remained in the inside of barrier rib material. In $H_2$O, two distinct peaks were observed: desorption from physically adsorbed one at $l00^{\circ}C$ and from chemically adsorbed one $400^{\circ}C$. The result can be utilized in interpretation of electronic and optical characteristics and evacuation process control of PDP

볶은 콩가루 첨가를 달리한 만두피의 특성 연구 (A Study on the Characteristics of Mandu-pi Differing in Roasted Soy Flour Content)

  • 변진원;남혜원;우인애
    • 한국식품영양학회지
    • /
    • 제14권4호
    • /
    • pp.287-292
    • /
    • 2001
  • The purpose of this study was to investigate the effect of roasted soy f1our on the characteristics of Mandu-pi. Various Mandu-pi samples were prepared with wheat flour along with the addition of different amount of roasted soy flour. and then instrumental characteristics and sensory evacuation were investigated. As a result of amylography study, there were no difference In the initial pasting and maximum viscosity temperatures between samples. And maximum viscosity decreased with the increase of flour addition. In farinography study, the addition of roasted sop f1our did not affect the gelatinization temperature, while stability and developing time of dough increased by addition of soy flour level. Besides cooked weight, cooked volume and water absorption of Mandu-pi were also higher significantly than control. The more soy flour was added, the less lightness and more redness and yellowness were obtained. The result of sensory evaluation revealer that there were no differences between samples in beano aroma, smoothness, and chewness. However Mandu-pi added roasted soy flour showed higher scores in surface appreance, nutty aroma, nutty taste. sweet taste, and overall preferance than control.

  • PDF

세월호 증개축 전후 승선객의 피난성능 예측비교 (Comparative Study on Predictions of Passengers' Evacuation Performances Before and After the Remodelling of MV SEWOL)

  • 황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.105-114
    • /
    • 2015
  • 여객선에서는 승선자의 안전이 가장 중요함에도 불구하고 국내에서는 인간의 피난행동특성을 반영한 피난성능에 관한 기준이 없다. 본 연구에서는 세월호 증개축 전후의 인적피난안전성을 비교 평가하고 이를 통해 현재 기준의 문제점을 도출하고자 하였다. 연구성과를 정리하면 다음과 같다. 첫째, 증개축 전후의 소집장소 면적은 동일하였고, 이 면적은 모두 국내 관련 기준을 만족하는 것으로 평가되지만, 인간의 행동특성을 반영한 인적안전피난시뮬레이션 툴을 활용하면 소집이 불가능한 것으로 판단된다. 둘째, 증개축 전후 선내 공간구성에 대해 각 선실에서 퇴선까지의 피난소요시간예측 시뮬레이션을 50회씩 수행한 결과 힐링각 $0^{\circ}$ 경우에는 모두 SOLAS의 허용기준이내이므로 승객 전원이 충분히 피난할 수 있을 것으로 평가되지만, 힐링각이 $20^{\circ}$인 긴급한 상황에서 피난을 개시할 경우에는 모두 SOLAS의 주간기준은 만족하지만, 야간기준은 만족하지 못하는 것으로 예측되었다. 모든 경우에서 증축 후인 세월호의 피난시간 확률분포가 Naminoue호의 피난시간 확률분포보다 분산되어 있는데 이는 증축후 피난환경이 열악해졌다는 의미이다.