• Title/Summary/Keyword: Eurocode 2

Search Result 149, Processing Time 0.027 seconds

Study on Deflection Evaluation for High-strength Concrete of KCI Specification and Eurocode 2 (콘크리트구조설계기준과 Eurocode 2의 고강도 콘크리트 처짐 산정에 관한 연구)

  • Lee, In-Ju;Kim, Tae-Wan;Kim, Sung-Hu;Son, Chang-Du;Park, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.989-992
    • /
    • 2008
  • Recently, high-strength concrete has been frequently used for long-span bridges and high-rise buildings. Deflection of reinforced concrete structures is uncertain, so that many researchers have proposed various equations in order to predict deflection through experiments. Domestic concrete specification offers a procedure to evaluate deflection using effective moment of inertia which was proposed by Branson. However, it is inaccurate for high strength concrete compared to the method suggested in Eurocode 2 in that Eurocode 2 predicts deflection by using curvature integration of effective moment of inertia. In this study, experimental data about deflection of reinforced concrete beams were analyzed to compare domestic standard and Eurocode 2.

  • PDF

Limit states design for tunnels: related researches and present state of application (터널 한계상태설계법 관련 연구 및 적용 동향)

  • Kim, Hong-Moon;Kim, Dong-Kook;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.341-346
    • /
    • 2014
  • The representative Limit State Design(LSD) codes, AASHTO LRFD and Eurocodes, are widely being applied when designing civil structures. However, these codes are only applying tunnel lining design and segments design for shield tunnels. Recently in Europe, the Eurocode 7 committee was trying to create a research group called EG12, but they reluctantly decided not to create EG12 since it could have an impact on some of the other Eurocodes(including Eerocodes 2 and 3). Still there is an effort to continue researching LSD for tunnelling. LSD method will become the norm for the field of civil structural design in the near future. Therefore, it is important to fully understand Eurocode7:Geotechnical design in connection with Eurocode 2 and Eurocode 3. In addition, it is essential to follow international research trends and also to research for application to tunnelling.

Curvature ductility of high strength concrete beams according to Eurocode 2

  • Bouzid, Haytham;Kassoul, Amar
    • Structural Engineering and Mechanics
    • /
    • v.58 no.1
    • /
    • pp.1-19
    • /
    • 2016
  • Recently, the high-strength concrete is increasingly used in the construction of reinforced concrete structures due to its benefits, but this use is influenced negatively on the local ductility of structural elements. The objective of this study is the prediction of a new approach to evaluate the curvature ductility factor of high strength concrete beams according to Eurocode 2. After the presentation of the Constitutive laws of materials and the evaluation method of curvature ductility according to the Eurocode 2, we conduct a parametric study on the factors influencing the curvature ductility of inflected sections. The calibrating of the obtained results allows predicting a very simple approach for estimating the curvature ductility factor. The proposed formula allows to calculate the curvature ductility factor of high strength concrete beams directly according to the concrete strength $f_{ck}$, the yield strength of steel $f_{yk}$ and the ratio of tension and compression reinforcements ${\rho}$ and ${\rho}^{\prime}$ respectively, this proposed formula is validated by theoretical and experimental results of different researchers.

Experimental Study on Deflection Evaluation of KCI specification and Eurocode 2 (콘크리트 구조 설계기준과 Eurocode 2의 처짐 산정에 관한 실험적 고찰)

  • Lee, In-Ju;Kim, Tae-Wan;Oh, Seok-Mim;Kim, Jun-Won;Park, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.141-144
    • /
    • 2008
  • Deflection in terms of serviceability of reinforced concrete structures is considered as one of significant factor. Domestic concrete specification offers a procedure to evaluate deflection using effective moment of inertia at cracked section, which has been known as Branson's equation in ACI. Branson's equation was derived from statistical analysis of maximum deflection of flexural members, but is somewhat weak in no reflection of bond characteristics between reinforced bars and concrete, such as tension stiffening effect. Therefore, present code creates difference from actual deflection. In this study, experiments about deflection of RC beams was completed to compare domestic standard and Eurocode 2, which calculates deflection considering tension stiffening effect. Four RC beams were built and tested, and initial modulus of elasticity and tensile strength of concrete used in the test was calculated by each design standard.

  • PDF

Reinforced concrete beam-column joints with lap splices under cyclic loading

  • Karabinis, Athanasios I.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.6
    • /
    • pp.649-660
    • /
    • 2002
  • Experimental results are presented from tests conducted on reinforced concrete beam-column joints with lap splices under reversed cyclic loading simulating earthquake action. Response curves are compared for twenty-four specimens designed according to Eurocode 2. The main parameters of the investigation are, the geometry of the reinforcing bar extension, the applied axial load (normalized), the available cover over lap splice region extended as length required from Eurocode 2, as well as the shape and the volumetric percentage of the stirrups confining the lap splice zone. The results are evaluated with regards to the load intensity, the energy absorption capacity and the characteristics of the load deflection curve.

Towards a consistant safety format of steel beam-columns: application of the new interaction formulae for ambient temperature to elevated temperatures

  • Vila Real, P.M.M.;Lopes, N.;Simoes da Silva, L.;Piloto, P.;Franssen, J.M.
    • Steel and Composite Structures
    • /
    • v.3 no.6
    • /
    • pp.383-401
    • /
    • 2003
  • Two new formulae for the design of beam-columns at room temperature have been proposed into Eurocode 3, prEN 1993-1-1 (2002), and are the result of great efforts made by two working groups that followed different approaches, a French-Belgian team and an Austrian-German one. Under fire conditions the prEN 1993-1-2 (structural fire design) presents formulae, for the design of beam-columns based on the prENV 1993-1-1 (1992). In order to study the possibility of having, in part 1-1 and part 1-2 of the Eurocode 3, the same approach, a numerical research was made using the finite element program SAFIR, developed at the University of Liege for the study of structures subjected to fire.

Cyclic mechanical model of semirigid top and seat and double web angle connections

  • Pucinotti, Raffaele
    • Steel and Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.139-157
    • /
    • 2006
  • In this paper, a cyclic mechanical model is presented to simulate the behaviour of top and seat with web angle beam-to-column connections. The introduced mechanical model is compared with Eurocode 3 Annex J, its extension, and with experimental data. To have a better insight regarding the actual response of the joints, available results of the experiments, carried out on full-scale top and seat angle joints under monotonic and cyclic loading, are first considered. Subsequently, a finite element model of the test setup is developed. The application of the proposed model, its comparisons with the experimental curves and with the Eurocode 3 Annex J and with its modification, clearly show the excellent quality of the model proposed.

Analytical Studies on the Shear Behavior of the Shear Connector in Composite Beam with Light Weight Concrete (경량콘크리트를 사용한 합성보에서 전단연결재의 전단거동에 관한 해석적 연구)

  • Choi, Byong Jeong;Han, Hong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.127-134
    • /
    • 2009
  • The purpose of this paper is to understand the shear characteristics of the shear connectors embedded into light weight concrete. This paper tried to confirm the validity of the finite element method(FEM) through the comparative study between the previous study results and FEM analysis, and evaluated the shear strength of shear connector and current design codes(AISC-LRFD and Eurocode 4) according to the variation of compressive strength of light weight concrete. This paper resulted that the shear strength of connector embedded into light weight concrete closely agreed to the one of shear connector by Eurocode 4 based on the results of the FEM analysis.

Reliability-based assessment of American and European specifications for square CFT stub columns

  • Lu, Zhao-Hui;Zhao, Yan-Gang;Yu, Zhi-Wu;Chen, Cheng
    • Steel and Composite Structures
    • /
    • v.19 no.4
    • /
    • pp.811-827
    • /
    • 2015
  • This paper presents a probabilistic investigation of American and European specifications (i.e., AISC and Eurocode 4) for square concrete-filled steel tubular (CFT) stub columns. The study is based on experimental results of 100 axially loaded square CFT stub columns from the literature. By comparing experimental results for ultimate loads with code-predicted column resistances, the uncertainty of resistance models is analyzed and it is found that the modeling uncertainty parameter can be described using random variables of lognormal distribution. Reliability analyses were then performed with/without considering the modeling uncertainty parameter and the safety level of the specifications is evaluated in terms of sufficient and uniform reliability criteria. Results show that: (1) The AISC design code provided slightly conservative results of square CFT stub columns with reliability indices larger than 3.25 and the uniformness of reliability indices is no better because of the quality of the resistance model; (2) The uniformness of reliability indices for the Eurocode 4 was better than that of AISC, but the reliability indices of columns designed following the Eurocode 4 were found to be quite below the target reliability level of Eurocode 4.