• 제목/요약/키워드: Eurocode

검색결과 357건 처리시간 0.02초

Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire

  • Yiran Wu;Xianglin Yu;Yongjiu Shi;Yonglei Xu;Huiyong Ban
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.269-287
    • /
    • 2023
  • The WGJ420 fire-resistant weathering (FRW) steel is developed and manufactured with standard yield strength of 420 MPa at room temperature, which is expected to significantly enhance the performance of steel structures with excellent fire and corrosion resistances, strong seismic capacity, high strength and ductility, good resilience and robustness. In this paper, the mechanical properties of FRW steel plates and buckling behavior of columns are investigated through tests at elevated temperatures. The stress-strain curves, mechanical properties of FRW steel such as modulus of elasticity, proof strength, tensile strength, as well as corresponding reduction factors are obtained and discussed. The recommended constitutive model based on the Ramberg-Osgood relationship, as well as the relevant formulas for mechanical properties are proposed, which provide fundamental mechanical parameters and references. A total of 12 FRW steel welded I-section columns with different slenderness ratios and buckling load ratios are tested under standard fire to understand the global buckling behavior in-depth. The influences of boundary conditions on the buckling failure modes as well as the critical temperatures are also investigated. In addition, the temperature distributions at different sections/locations of the columns are obtained. It is found that the buckling deformation curve can be divided into four stages: initial expansion stage, stable stage, compression stage and failure stage. The fire test results concluded that the residual buckling capacities of FRW steel columns are substantially higher than the conventional steel columns at elevated temperatures. Furthermore, the numerical results show good agreement with the fire test results in terms of the critical temperature and maximum axial elongation. Finally, the critical temperatures between the numerical results and various code/standard curves (GB 51249, Eurocode 3, AS 4100, BS 5950 and AISC) are compared and verified both in the buckling resistance domain and in the temperature domain. It is demonstrated that the FRW steel columns have sufficient safety redundancy for fire resistance when they are designed according to current codes or standards.

Evaluation of EC8 and TBEC design response spectra applied at a region in Turkey

  • Yusuf Guzel;Fidan Guzel
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.199-208
    • /
    • 2023
  • Seismic performance analysis is one of the fundamental steps in the design of new or retrofitting buildings. In the seismic performance analysis, the adapted spectral acceleration curve for a given site mainly governs the seismic behavior of buildings. Since every soil site (class) has a different impact on the spectral accelerations of input motions, different spectral acceleration curves have to be involved for every soil class that the building is located on top of. Modern seismic design codes (e.g., Eurocode 8, EC8, or Turkish Building Earthquake Code, TBEC) provide design response spectra for all the soil classes to be used in the building design or retrofitting. This research aims to evaluate the EC8 and TBEC based design response spectra using the spectra of real earthquake input motions that occurred (and were recorded at only soil classes A, B and C, no recording is available at soil class D) in a specific area in Turkey. It also conducts response spectrum analyses of 5, 10 and 13 floor reinforced concrete building models under EC8, TBEC and actual spectral response curves. The results indicate that the EC8 and especially TBEC given design response spectra cannot be able to represent the mean actual spectral acceleration curves at soil classes A, B and C. This is particularly observed at periods higher than 0.3 s, 0.42 s and 0.55 s for the TBEC design response spectra, 0.54 s, 0.65 s and 0.84 s for the EC8 design response spectra at soil classes A, B and C, respectively. This is also reflected to the shear forces of three building models, as actual spectral acceleration curves lead to the highest shear forces, followed by the shear forces obtained from EC8 and, then, the TBEC design response spectra.

지반신뢰성 설계를 위한 설계변수의 특성치 연구 (Characteristic Values of Design Parameters for Geotechnical Reliability Design)

  • 윤길림;윤여원;김홍연
    • 한국지반공학회논문집
    • /
    • 제24권5호
    • /
    • pp.27-35
    • /
    • 2008
  • 신뢰성 설계를 위한 설계변수의 특성치에 대하여 국내 해양토질을 이용하여 연구하였다. 특성치 산정에 대한 연구결과, Student/Ovesen, Schneider 및 EN 1990 방법의 순으로 평균치에 근접한 것으로 나타났고, EN 1990 방법은 지반특성치 산정방법의 신뢰성 차원에서 부적합한 것을 확인하였다. 그리고 제시된 네가지 특성치 산정방법은 토질의 변동성이 커짐에 따라 특성치를 보수적으로 평가하는 경향을 보였다. 또한 이러한 산정된 특성치가 실 설계에 미치는 영향을 파악하기 위하여 방파제에 대하여 임의 하중하에서 미개량 지반의 지지력 및 침하특성을 검토하였다. Schneider 방법을 이용하여 산정한 결과와 토질정수의 산술평균치를 이용한 결과를 비교한 결과, 허용지지력/작용하중비의 경우 전자가 후자의 65%로 나타났고, 침하량의 경우에는 13.6%를 제시하여 과소평가한 결과였다. 그리고 과거 설계사례에서 산술평균치로 결정된 대표치에 의한 것과 본 논문에서 각 지역의 자료로부터 산정한 특성치에 따른 설계결과를 비교한 결과, 산술평균치로 결정된 대표치에 의한 설계는 대부분 과대평가의 결과를 제시하였다.

Compressive behavior of concrete-filled square stainless steel tube stub columns

  • Dai, Peng;Yang, Lu;Wang, Jie;Ning, Keyang;Gang, Yi
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.91-106
    • /
    • 2022
  • Concrete-filled square stainless steel tubes (CFSSST), which possess relatively large flexural stiffness, high corrosion resistance and require simple joint configurations and low maintenance cost, have a great potential in constructional applications. Despite that the use of stainless steel may result in high initial cost compared to their conventional carbon steel counterparts, the whole-life cost of CFSSST is however considered to be lower, which offers a competitive choice in engineering practice. In this paper, a comprehensive experimental and numerical program on 24 CFSSST stub column specimens, including 3 austenitic and 3 duplex stainless steel square hollow section (SHS) stub columns and 9 austenitic and 9 duplex CFSSST stub columns, has been carried out. Finite element (FE) models were developed to be used in parametric analysis to investigate the influence of the tube thickness and concrete strength on the ultimate capacities more accurately. Comparisons of the experimental and numerical results with the predictions made by design guides ACI 318, ANSI/AISC 360, Eurocode 4 and GB 50936 have been performed. It was found that these design methods generally give conservative predictions to the ultimate capacities of CFSSST stub columns. Improved calculation methods, developed based on the Continuous Strength Method, have been proposed to provide more accurate estimations of the ultimate resistances of CFSSST stub columns. The suitability of these proposals has been validated by comparison with the test results, where a good agreement between the predictions and the test results have been achieved.

Static and fatigue performance of short group studs connector in novel post-combination steel-UHPC composite deck

  • Han Xiao;Wei Wang;Chen Xu;Sheraz Abbas;Zhiping Lin
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.659-674
    • /
    • 2024
  • Casting Ultra High-Performance Concrete (UHPC) on an orthotropic steel deck and forming a composite action by connectors could improve the steel deck fatigue performance. This study presents the mechanical performance of a proposed post-combination connection between UHPC and steel, which had a low constraint effect on UHPC shrinkage. A total of 10 push-out tests were conducted for static and fatigue performance investigations. And the test results were compared with evaluation methods in codes to verify the latter's applicability. Meanwhile, nonlinear simulation and parametric works with material damage plasticity models were also conducted for the static and fatigue failure mechanism understanding. The static and fatigue test results both showed that fractures at stud roots and surrounding local UHPC crushes were the main failure appearances. Compared with normally arranged studs, group arrangement could result in reductions of static stud shear stiffness, strength, and fatigue lives, which were about 18%, 12%, and 27%, respectively. Compared with the test results, stud shear capacity and fatigue lives evaluations based on the codes of AASHTO, Eurocode 4, JSCE and JTG D64 could be applicable in general while the safety redundancies tended to be smaller or even insufficient for group studs. The analysis results showed that arranging studs in groups caused obviously uneven strain distributions. The severer stress concentration and larger strain ranges caused the static and fatigue performance degradations of group studs. The research outcome provides a very important basis for establishing a design method of connections in the novel post-combination steel-UHPC composite deck.

인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석 (Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior)

  • 유성원;양인환;정상화
    • 콘크리트학회논문집
    • /
    • 제27권2호
    • /
    • pp.185-193
    • /
    • 2015
  • 인장강도 및 휨강도가 낮고 취성파괴의 특성을 가지는 일반적인 콘크리트의 단점을 극복하기 위하여 최근에는 압축강도가 180 MPa이상인 고성능 콘크리트에 강섬유를 혼입한 강섬유 보강 초고성능 콘크리트(UHPC)에 대한 연구가 활발히 진행되고 있다. UHPC 바닥판과 강재 거더를 이용하여 합성보를 구성할 때, UHPC 바닥판의 높은 강도와 강성으로 인하여 강재거더 상부 플랜지의 역할이 거의 불필요할 것으로 예상된다. 이러한 점을 착안하여 본 논문에서는 합성보 구성 시에 강재 거더의 상부플랜지를 없앤 역T형 거더를 적용하였다. 역T형 거더에 UHPC바닥판을 합성하여 합성보를 구성할 경우, 상부플랜지가 없는 이유로 전단연결재의 설치 위치가 상부플랜지 대신에 강재 거더 복부에 설치해야하는 문제점이 발생되며, 강재 복부에 설치되는 전단연결재에 대한 거동, 역T형 강거더 합성보의 휨거동 특성 등은 현재까지 실험 및 이론적으로 평가된 적이 거의 없는 실정인 이유로 이에 대한 연구가 절실하다. 이를 위하여 본 논문에서는 전단연결재 간격, 바닥판 두께 등을 변수로 하여 역T형 거더와 UHPC바닥판을 합성한 합성보를 8개 제작하여 전단연결재의 거동, 휨거동 특성 등을 파악하고자 하였다. 또한, 강섬유 보강 초고성능 콘크리트의 인장연화거동을 고려한 재료모델링 및 이를 적용한 보 부재 단면의 변형률 적합조건을 이용한 해석모델을 제안하였다. 실험결과 및 해석결과를 기준으로 볼 때, UHPC 콘크리트의 경우 전단연결재의 간격은 100 mm에서 바닥판 두께의 2~3배 사이로 규정함이 적절한 것으로 나타났다. 실험결과와 해석결과를 종합적으로 비교하면, 강섬유 보강 초고성능 콘크리트 합성보의 실험결과와 해석결과는 비교적 잘 일치하고 있으므로 재료 실험으로부터 산정된 인장연화곡선은 강섬유 보강 초고성능 콘크리트의 실제 거동을 합리적으로 반영한다고 판단된다. 따라서, 본 연구에서 제시한 인장연화거동 특성을 반영한 강섬유 보강 초고성능 콘크리트의 재료모델링 및 휨거동 해석기법은 적절하며, 제시기법에 의해 강섬유보강 초고성능 콘크리트 합성 부재의 휨 내력을 합리적으로 예측할 수 있을 것으로 예상된다.

각형 콘크리트충전 강관기둥 부재의 구조설계기준 비교연구 (Review of Structural Design Provisions of Rectangular Concrete Filled Tubular Columns)

  • 이철호;강기용;김성용;구철회
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 본 연구에서는 향후 기준집필 및 연구방향 제시를 위한 선행연구로써, 2005/2010 AISC, ACI 318-08과 EC4 내 각형 CFT 기둥 설계조항 간의 부재강도 산정포맷, 단면구조성능, 구속효과. 재료강도 상한 및 강재비, 판-폭 두께비 제한 등을 간략히 요약하고 비교분석하였다. 전반적으로 2010 AISC는 ACI 기준과의 충돌 완화를 위해 변형률적합법을 도입하는 등 최신 실험 및 연구 결과들을 반영하여 개정하였으며 CFT 기둥에서 세장비를 더욱 세분화하거나 내진 판-폭 두께비를 고연성과 중간연성 부재로 구분하는 등, 타 기준에 비해 발전된 형태의 방안을 제시하고 있다. 하지만 AISC와 EC4에서의 재료강도 상한치는 너무나 제한적이기때문에 현재 사용 가능한 고강도 재료실험 데이터베이스를 고려하여 완화할 필요가 있다. 본 연구를 통해 AISC, ACI, EC4에서 제시하는 각형 CFT 기둥의 P-M 조합강도 산정식은 다양한 설계조건에 대해 만족스러운 강도예측을 하지 못함을 확인하였다. 따라서 각형 CFT 기둥의 신뢰도 높은 P-M 조합강도 산정을 위하여 구속된 콘크리트의 응력-변형률 관계를 합리적으로 반영할 수 있는 실용적인 구성 방정식이 개발되어야 한다.

철도교 바닥판용 프리캐스트 패널과 합성 바닥판의 휨거동에 대한 실험적 연구 (Experimental Study for the Bending Behavior of Precast Concrete Panel and Composite Deck for Railway Bridge)

  • 설대호;이경찬;윤석구
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.21-31
    • /
    • 2018
  • 이 논문은 철도교 교량 바닥판의 영구거푸집 목적으로 개발된 리브가 부착된 프리캐스트 콘크리트 패널과 그 패널을 적용한 교량바닥판의 구조 성능 검증을 위한 정적하중재하실험을 수행결과를 정리하였다. 영구거푸집 용도의 리브가 부착된 프리캐스트 패널을 대상으로 폭 400mm 보부재와 폭 1200mm 판부재를 각각 3개씩 제작하였고 후타설 콘크리트와 리브가 부착된 프리캐스트 콘크리트 패널이 합성된 교량 바닥판 부재를 대상으로 폭 400mm 보부재와 폭 1200mm 판부재를 각각 3개씩 제작하여 총 12개의 실험체에 대하여 정적하중재하 실험을 수행하였다. 모든 실험체의 단면은 바닥판 설계지간 1.6m를 갖는 두께 240mm의 철도교 바닥판을 가정하여 결정하였고, 시공하중이 작용하는 프리캐스트 패널에 대하여 콘크리트 표준시방서에 따른 거푸집 설계하중을 재하하였을 때 리브가 부착된 프리캐스트 콘크리트 패널 하면의 인장응력이 콘크리트 인장강도를 초과하지 않도록 단면을 설계하였다. 각 실험체에 대하여 하중에 따른 철근변형률, 콘크리트 변형률, 균열폭, 처짐, 합성부재의 시공이음면의 슬립량을 계측하여 그 결과로부터 구조물의 안전성과 사용성 평가를 수행하였다. 모든 실험체는 현행 설계기준에서 요구되는 안전성 및 사용성 기준을 만족하는 것으로 나타났다.

사장교형식 보도교의 보행진동제어를 위한 TMD 적용 (Application of Tuned Mass Damper to Suppress Man-Induced Vibrations of Cable Stayed Foot-bridge)

  • 김윤석;이승우;김재민;장성규
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.74-74
    • /
    • 2011
  • 본 연구에서는 중앙경간 54m, 교폭 4m의 사장교형식의 보도교로 측경간은 계단으로 이루어진 1경간 케이블교량을 대상으로 보행하중에 의한 수직진동을 제어하기 위해 제진장치(TMD)를 적용하기로 하고 실물 TMD의 설계 및 제작 그리고 설치 및 제어성능실험을 수행하였다. 우선 사장교형식의 교량. 그리고 1경간 교량이라는 점에서 상대적으로 감쇠율이 낮을 것으로 예측되었고 또한 54m의 경간장이 보행자가 가진 주파수에 근접한 고유진동수를 나타낼 것으로 사료되어 Eurocode 2 part 2(EC5-2)의 규준에 따라 1인 및 다수 보행하중에 의한 보도교의 발생가속도를 산출하였다. 이 경우 최대가속도는 다수의 보행자가 연속적으로 진행할 때 발생하였으며, 수직방향의 가속도가 사용성기준을 초과하는 것으로 나타났다. 또한 구조해석프로그램에 의한 고유치 해석결과, 보행하중의 주파수대역내에 진동모드가 존재하는 것으로 나타났다. 따라서 본 교량의 설계단계에 있어서 보행진동을 제어하기 위하여 유지관리가 용이한 수동형의 동조질량감쇠장치(Tuned Mass Damper)를 적용하기로 하였으며 TMD의 설계에서는 TMD의 제어목표를 만족시킬 수 있는 TMD의 가동질량(moving mass)을 우선적으로 결정하였고, 이로부터 Den Hartog의 제안식에 따라 TMD의 고유진동수비, 유효감쇠비를 산정하였다. 산정된 변수들을 이용하여 설계된 TMD는 현장설치 및 튜닝의 편의성을 고려하여 수평 외팔보형식으로 설계, 제작되었으며 제작된 TMD의 경우 회전축에 대해 질량, 스프링, 댐퍼의 중심거리를 조정함으로써 TMD의 진동수, 강성, 감쇠력을 상대적으로 매우 용이하게 조절할 수 있으며, 조정범위 또한 광범위하여 일반 TMD에 비해 현장설치시 대상구조물에 동조시키기가 용이하며, 작동시 마찰감쇠가 거의 없다는 장점이 있다. 현장설치전에 제작된 TMD를 대상으로 자유진동 시험을 통하여 질량의 중심거리, 스프링 크기 그리고 댐퍼의 설치유무를 각각 변화시키며 TMD의 자유진동 데이터를 취득하였다. 각각의 시험에서 얻어진 데이터로부터 스펙트럼해석을 통하여 고유진동수를 구하였고, 자유진동 파형으로 부터 감쇠비를 구하였다. TMD는 일반적으로 제어모드의 변형형상이 가장 큰 곳에 설치되었을 때 최대의 제진효과를 발휘할 수 있다. 그러나 현장여건상 설치가 불가능하거나 미관을 해치는 경우에는 가능한 범위 내에서 TMD 제어효율이 가장 크게 발휘할 수 있는 곳을 선택하여야 한다. 본 보도교의 경우, 중앙경간 중심부에서 가장 큰 모드변형형상을 나타내지만, 보도교의 상판 연결부 등에 따른 TMD 시공문제로 인하여 TMD 설치위치는 교량 중앙에서 양 방향으로 1.25m 떨어진 곳에 대칭으로 총 2기를 설치하기로 하였다. 일반적으로 TMD의 모든 설계변수는 구조물의 설계단계에서 수행된 구조해석결과에 근거하여 설정하므로 완공된 구조물, 즉 실제보도교의 동적특성을 계측하여 정확하게 진동수를 튜닝하여야 한다. 구조해석에 의한 보도교의 수직방향(TMD 작동방향) 고유진동수는 1.5225 Hz이며, 감쇠비는 규준에 의하여 0.6 %로 가정하였다. 그러나 이 값들은 구조해석모델 및 재료적 특성과 시공상의 오차에 의하여 실제와 다를 수 있으므로 현장계측에 의한 확인이 요구된다. 또한 TMD의 제진효율이 설계시의 목표대로 확보되었는지도 확인해야 하므로 현장튜닝 및 성능시험을 실시하였다. 보도교의 가진은 사전에 실시한 상시 미진동계측결과를 토대로 2Hz를 목표로 하여 인력가진실험을 수행하였고, 탁월진동 주파수는 1.9896Hz로 나타나 구조해석결과와 오차가 있음을 알 수 있다. 가진실험결과를 토대로 TMD의 진동수를 최적진동수비로 튜닝하고 인력가진 실험을 다시 실시하여 TMD의 진동제어성능을 검토하였다. TMD 튜닝 전, 후의 보도교 감쇠비를 비교한 결과, TMD를 설치함으로써 약 4.218%의 감쇠비 증가가 있음을 알 수 있다.

  • PDF

유로코드 2 재료모형을 사용한 철근콘크리트 부재의 연성도 평가 (Evaluation of Ductility in Reinforced Concrete Members Using Material Models in Eurocode2)

  • 최승원
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.287-297
    • /
    • 2015
  • 철근콘크리트 부재의 연성을 확보하기 위하여 콘크리트구조기준에서는 철근의 최소 허용 변형률에 대한 지침을 두고 있고, EC2에서는 중립축 깊이와 유효 깊이의 비(c/d)를 제한하고 있다. 일반적으로 철근콘크리트 부재의 연성 능력은 항복변위와 극한변위의 비로서 표현되는 변위 연성도를 통해 평가하는데, 변위 연성도를 정확하게 산정하기 위해서는 항복변위와 극한변위에 대한 정립이 필수적이다. 그러나 실제 부재의 변위는 부재의 다양한 특성에 영향을 받으므로 이들 값을 정확하게 산정하는 것은 어렵다. 이 연구에서는 철근콘크리트 부재의 항복변위 및 극한변위를 휨모멘트-휨곡률 관계를 통해 직접 계산하여 변위 연성도를 산정하였다. 해석의 주요 변수는 콘크리트 압축강도, 주철근 항복강도, 주철근 비, 횡철근 간격, 축력비 및 콘크리트 극한변형률이다. 해석 결과 콘크리트 압축강도가 증가할수록 변위 연성도는 증가하였다. 반면에 주철근의 항복강도, 주철근 비, 횡철근 간격 및 축력비가 증가할수록 변위 연성도는 감소하였다. 그리고 변위 연성도는 기둥의 내진설계에 사용되는 응답수 정계수(R)의 산정에 필수적이므로 변위 연성도를 정확하게 산정하는 것이 필수적이라고 판단된다.