• Title/Summary/Keyword: Estimated Total Down Time

Search Result 17, Processing Time 0.021 seconds

A Study on Genetic Algorithm of Concurrent Spare Part Selection for Imported Weapon Systems (국외구매 무기체계에 대한 동시조달수리부속 선정 유전자 알고리즘 연구)

  • Cho, Hyun-Ki;Kim, Woo-Je
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.3
    • /
    • pp.164-175
    • /
    • 2010
  • In this study, we developed a genetic algorithm to find a near optimal solution of concurrent spare parts selection for the operational time period with limited information of weapon systems purchased from overseas. Through the analysis of time profiles related with system operations, we first define the optimization goal which maintains the expected system operating rate under the budget restrictions, and the number of failures and the lead time for each spare part are used to calculate the estimated total down time of the system. The genetic algorithm for CSP selection shows that the objective function minimizes the estimated total down time of systems with satisfying the restrictions. The method provided by this study can be applied to the generalized model of CSP selection for the systems purchased from overseas without provision of their full structure and adequate information.

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

Design Considerations of Cryogenic Cooling System for High Field Magnets

  • Choi, Yeon-Suk;Kim, Dong-Lak;Lee, Byoung-Seob;Yang, Hyung-Suk;Yoo Jong-Shin;Painter Thomas A.;Miller John R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.30-33
    • /
    • 2006
  • Several crucial issues are discussed in the design of cryogenic cooling system for high field magnets. This study is mainly motivated by our ongoing program to develop a 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The magnets of this system will be built horizontally to accomplish the requirement of user friendliness and reliability, and the replenishment of cryogen will not be necessary by a closed-loop cooling concept. The initial cool-down and safety are basically considered in this paper. The effects of the helium II volume and the gap distance of the weight load relief valve (or safety valve) on the cool-down time and temperature rising during an off-normal state are discussed. The total amount of cryogenic cooling loads and the required helium flow rate during cool-down are also estimated by a relevant heat transfer analysis. The temperatures of cryogen-free radiation shield are finally determined from the refrigeration power of a cryocooler and the total cryogenic loads.

A study on the dental technology and fabrication cost analysis of implant prosthesis for National Health Insurance (건강보험 급여화 관련 임플란트보철물의 기공원가 분석 연구)

  • Cho, Mi-Hyang;Lee, Gwang-Young;Lee, Hee-kyung;Nam, Shin-Eun;Ryu, Jae-Kyung;Kwon, Hyok-Mun;Kim, Kyung-Rok;Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.149-162
    • /
    • 2020
  • Purpose: The purpose of this study was to conduct a cost accounting of implant prosthesis according to the fabrication activities. Methods: In this study, the cost price of implant prosthesis fabrication activities was calculated by the bottom-up costing approach for material and labor cost and the top-down costing approach for expenses and other. Results: The total cost price was estimated to 220,000 ~ 310,000 won per one implant prosthesis. By product, the screw type was estimated to 220,000 ~ 230,000 won, and when the stent and tray were included, it was 260,000 ~ 270,000 won, which increased about 40,000 won. And, the cement type with more material and labor time was estimated to 250,000 ~ 260,000 won, and when the stent and tray were included, it was about 300,000 won. Conclusion: In terms of the fabrication cost ratio by items, it was shown that material cost and labor cost accounted for about 40% and 30% of the total cost structure for resin case, respectively, which was the opposite for porcelain. It was shown that expenses and general administrative expenses accounted for about 15%, and profits were about 11% ~ 14% in both cases.

Estimation of Application Cost and Utilization of Turf Grass VFS for Reduction of Uplands NPS Pollution (밭 비점오염저감을 위한 잔디초생대 적용 비용 및 활용성 평가)

  • Lee, Seul-Gi;Jang, Jeong-Ryeol;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.2
    • /
    • pp.75-83
    • /
    • 2015
  • This study was aimed to estimate the total application cost and utilization of Turf grass VFS application through the field experiment. The experimental plots were constructed in an upland field of Iksan city within the Saemangeum watershed. Turf grass was transplanted at the down-slope edge of the pollution source area in each of the treated plots. Three rainfall events were monitored during the experiment period, and the rainfall-runoff relationships and NPS pollution reduction effects of the VFS systems were assessed. As results, the reduction ratio of runoff volume ranged 14.1~64.0 %, while the NPS pollution reduction ratio ranged 9.8~73.9 % for SS, 24.0~84.2 % for T-N, 31.6~80.9 % for T-P respectively. The total cost of VFS application was estimated by considering purchase cost of Turf grass sods and construction and maintenance costs of VFS system as well as the loss caused by giving up crop cultivation for the area needed to construct the VFS. The total cost of the VFS was estimated to be approximately \3,379,000/ha/year for the first year of application, and this cost could be decreased to \1,899,000/ha/year from the second year as the construction cost of VFS could no longer need to be counted afterwards. Apart from the NPS pollution reduction effects, the possible utilization of VFS was examined by detaching Turf grass within 40 % of VFS area for sale during spring time when the VFS systems fully covered. The benefit of selling the detached Turf grass sods was estimated as \1,260,000/ha/year, and also found that the VFS area successfully recovered by the time of the summer period. This benefit could attract farmers to adopt the VFS technique to manage agricultural NPS pollution.

An Analysis of Water Consumption Structures in Korean Industry Using the Input-Output Model (산업연관모형을 이용한 우리나라 산업의 직·간접 물소비 구조 분석)

  • Park, Chang-Gui;Lee, Ki-Hoon
    • Journal of Environmental Policy
    • /
    • v.9 no.2
    • /
    • pp.21-39
    • /
    • 2010
  • In this paper, water consumption annually for industries in Korea was estimated for the first time and based on this, an input-output model was prepared for water consumption analysis. Also making use of this, the direct and indirect water consumption effect according to industrial activities was analyzed and the total effect based on volume was broken down into each factor. The amount of water consumed for industries in Korea (excluding agriculture, forestry and fishery) was estimated about 7 billion and 692 million ton in 2003(excluding sea water). Classifying by industry, the one for electric power & water service accounted for almost half, 49.5%, metalworking industry for 24.3% and chemical industry for 5.0%. As the result of estimation for the direct and indirect water consumption inducement coefficients, the amount of water consumed per the production of one million won ranked the highest for electric power & water service as 113.8 ton and the next highest ones ranked as 49.6 ton for the first metalworking, 16.8 ton for textile and leather goods, and 11.9 ton for general machinery respectively. In the meantime, as the result of breaking down into each factor of total amount of water consumed by industry, it appeared that the ripple effect having on other industries was more than the direct effect.

  • PDF

A Study on the Estimation Method of EHP of Fishing Boats Use Statistical Regression Analysis (통계적 회귀계수를 이용한 어선의 유효 마력 추정법에 관한 연구)

  • Lee, Guen-Moo;Park, Jai-Woung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.199-209
    • /
    • 1995
  • From the results of model tests, statistical regression analysis of EHP estimation based on hull form parameters is adopted in this study. From this result, the method for estimation of EHP at the initial design stage of fishing boats is developed. This method is applied to four standard fishing boats with chine lines and two standard fishing boats with round bottom. The EHP's are estimated and compared to experimental results. In the case of six fishing boats, the estimated EHP corresponds well and approximates well with experimental results through out all the range tested. From these results it can be concluded that this numerical method is very efficient in estimating EHP of fishing boats having chine line and round bottom. Therefore, by applying the proposed method to design of fishing boats, we can improve the resistance characteristics. Further, this method can contribute to reduction of design time and thus down the total expenses.

  • PDF

A Study on Subchronic Inhalation Toxicity of 2-Methylpentane (2-Methylpentane 아만성 흡입독성 연구)

  • Chung, Yong Hyun;Lim, Cheol Hong;Han, Jeong Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2014
  • Objectives: The purpose of this study was to obtain information regarding classification and health hazards that may result from a 13-week inhalation exposure to 2-methylpentane by Sprague-Dawley rats. Materials: The testing method was conducted in accordance with OECD guidelines for the testing of chemicals No. 413. The rats were divided into four groups(ten male and ten female rats in each group) and exposed to 0 ppm, 290 ppm, 1,160 ppm, 4,640 ppm 2-Methylpentane in each exposure chamber for six hours per day, five days per week, for 13 weeks. Results: No death or particular clinical presentation including weight change and change of feed rate was observed. The relationships between dose, gender and response were also not significantly changed in urinalysis, hematologic examination, or biochemical examination of blood(except for total cholesterol being up, total protein being up, and chloride ion being down in males), and blood coagulation time. For the relative weight measurement of organs, in the male group the weight change of both kidney and liver were increased in proportion to dose. In histopathological examination, nephropathy in the kidney(cystic change of renal tubules, regenerative tubule, inflammatory cell infiltration and necrosis in the interstitial tissue) was increased in a dose-dependent manner in the male group(290 ppm, 1,160 ppm, 4,640 ppm). However, other organs were not affected by the test substance. Conclusions: 2-methylpentane was estimated as a chemical causing nephropathy in the male group. NOAEL(No Observable Adverse Effect Level) in the female group is more than 4,640 ppm, while inthe male group it is less than 290 ppm.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

How effective has the Wairau River erodible embankment been in removing sediment from the Lower Wairau River?

  • Kyle, Christensen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.237-237
    • /
    • 2015
  • The district of Marlborough has had more than its share of river management projects over the past 150 years, each one uniquely affecting the geomorphology and flood hazard of the Wairau Plains. A major early project was to block the Opawa distributary channel at Conders Bend. The Opawa distributary channel took a third and more of Wairau River floodwaters and was a major increasing threat to Blenheim. The blocking of the Opawa required the Wairau and Lower Wairau rivers to carry greater flood flows more often. Consequently the Lower Wairau River was breaking out of its stopbanks approximately every seven years. The idea of diverting flood waters at Tuamarina by providing a direct diversion to the sea through the beach ridges was conceptualised back around the 1920s however, limits on resources and machinery meant the mission of excavating this diversion didn't become feasible until the 1960s. In 1964 a 10 m wide pilot channel was cut from the sea to Tuamarina with an initial capacity of $700m^3/s$. It was expected that floods would eventually scour this 'Wairau Diversion' to its design channel width of 150 m. This did take many more years than initially thought but after approximately 50 years with a little mechanical assistance the Wairau Diversion reached an adequate capacity. Using the power of the river to erode the channel out to its design width and depth was a brilliant idea that saved many thousands of dollars in construction costs and it is somewhat ironic that it is that very same concept that is now being used to deal with the aggradation problem that the Wairau Diversion has caused. The introduction of the Wairau Diversion did provide some flood relief to the lower reaches of the river but unfortunately as the Diversion channel was eroding and enlarging the Lower Wairau River was aggrading and reducing in capacity due to its inability to pass its sediment load with reduced flood flows. It is estimated that approximately $2,000,000m^3$ of sediment was deposited on the bed of the Lower Wairau River in the time between the Diversion's introduction in 1964 and 2010, raising the Lower Wairau's bed upwards of 1.5m in some locations. A numerical morphological model (MIKE-11 ST) was used to assess a number of options which led to the decision and resource consent to construct an erodible (fuse plug) bank at the head of the Wairau Diversion to divert more frequent scouring-flows ($+400m^3/s$)down the Lower Wairau River. Full control gates were ruled out on the grounds of expense. The initial construction of the erodible bank followed in late 2009 with the bank's level at the fuse location set to overtop and begin washing out at a combined Wairau flow of $1,400m^3/s$ which avoids berm flooding in the Lower Wairau. In the three years since the erodible bank was first constructed the Wairau River has sustained 14 events with recorded flows at Tuamarina above $1,000m^3/s$ and three of events in excess of $2,500m^3/s$. These freshes and floods have resulted in washout and rebuild of the erodible bank eight times with a combined rebuild expenditure of $80,000. Marlborough District Council's Rivers & Drainage Department maintains a regular monitoring program for the bed of the Lower Wairau River, which consists of recurrently surveying a series of standard cross sections and estimating the mean bed level (MBL) at each section as well as an overall MBL change over time. A survey was carried out just prior to the installation of the erodible bank and another survey was carried out earlier this year. The results from this latest survey show for the first time since construction of the Wairau Diversion the Lower Wairau River is enlarging. It is estimated that the entire bed of the Lower Wairau has eroded down by an overall average of 60 mm since the introduction of the erodible bank which equates to a total volume of $260,000m^3$. At a cost of $$0.30/m^3$ this represents excellent value compared to mechanical dredging which would likely be in excess of $$10/m^3$. This confirms that the idea of using the river to enlarge the channel is again working for the Wairau River system and that in time nature's "excavator" will provide a channel capacity that will continue to meet design requirements.

  • PDF