• Title/Summary/Keyword: Esthetic function

Search Result 228, Processing Time 0.023 seconds

Implant assisted removable partial denture using a few remaining maxillary teeth and locator bar system: A case report (소수 잔존치를 가진 상악에 Bar와 Locator®를 이용한 임플란트 융합 국소의치 치료 증례)

  • Kim, Seong-Jung;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.528-536
    • /
    • 2017
  • Treatment with removable partial denture is effective for partially edentulous patients who are unable to obtain sufficient retention and stability for functional and esthetic restoration. There are several cases reporting the improvement of retention and stability of the partial denture using a small number of implants. However, there are limited studies on the implant-assisted removable partial denture using a small number of remaining teeth and the bar locator system. The bar locator system has an advantage in that it could compensate the angle of insertion of removable prosthesis on implant with inconsistent placement angle due to anatomical constraints compared to when using the locator only. This case report describes the patient with $Parkinson^{\circ}$Øs disease who was treated with the Locator bar system using two previously placed implants and two remaining teeth on maxilla. No additional implants could be placed because of the medical and economic condition of the patients, and the angle of one of two implants could not be matched with the direction of the removable partial denture insertion. Considering the angle of the implants, the patient was treated with implant-assisted RPD using the Locator bar system and had satisfactory results in the aspect of esthetics, masticatory function, and oral hygiene maintenance.

  • PDF

Full mouth rehabilitation of the patient with severely worn dentition using monolithic zirconia prosthesis: A clinical report (치아 마모 환자에서 단일 구조 지르코니아를 이용한 완전 구강 회복 증례)

  • Kim, Tae-Yeon;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.140-145
    • /
    • 2016
  • Excessive occlusal wear causes loss of tooth structure, occlusal plane disharmony, impaired function and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by the growth of alveolar bone and tooth eruption, minimal increase of occlusal vertical dimension may be required for esthetics and retention of prosthesis. In this case, a 44-year-old male patient visited Seoul National University Dental Hospital with chief complaint of severe tooth wear and shade disharmony. Based on assessment of diagnostic wax-up, 3 mm increase of occlusal vertical dimension was determined. Removable occlusal splint and interim prosthesis was used to ascertain patient's comfort and adaptation. After the adaptation period, definitive prosthesis fabricated with full-contour monolithic zirconia were delivered and the patient was recommended to wear a nightguard device for prosthesis protection. This report presents a case of full mouth rehabilitation with the elevation of patient's occlusal vertical height, resulting in satisfactory esthetics and functions.

TREATMENT OF TRANSPOSED MAXILLARY CANINE AND MANDIBULAR LATERAL INCISOR: A CASE REPORT (전위된 상악 견치 및 하악 측절치의 치험례)

  • Kwon, Hae-Sook;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.647-653
    • /
    • 2009
  • Tooth transposition is an anomaly of eruption characterized by the interchanged positions of two adjacent teeth, which is divided into complete and incomplete transposition. There are three common approaches for treating transposition: aligning the involved teeth in their transposed positions, moving them to their correct anatomic position in the arch and extracting one of the transposed teeth. Considerations in treatment plans are esthetic, function, risk of jeopardizing the roots and damaging the supporting structures, position of the root apex, developmental stages of teeth and expected compliance. The presented case reports described one maxillary canine-the first premolar transposition and two mandibular lateral incisor-canine transpositions. The former transposed teeth were arranged in their transposed position, and the latter transposed teeth were rearranged into their normal position.

  • PDF

Improvement of Articulation Disorder Using Flexible Partial Denture in Intellectural Disability Patient with Missing Lower Incisors (하악 전치부 상실로 인한 조음장애를 보이는 경도 지적장애 환아에서 탄성의치를 통한 조음능력의 향상)

  • Choi, Haein;Choi, Byungjai;Choi, Hyungjun;Song, Jeseon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.306-313
    • /
    • 2013
  • Speech is complex psycho-physiological mutual process which includes many orofacial organs. Especially, teeth play an especially important role as an articulation organ in conjunction with the lips and tongue. When teeth are missing, the position of tongue and mandible is adjusted to produce correct sound. If a patient's adaptive function is inadequate for modification of malocclusion, prosthodontic and orthodontic interventions are necessary. Missing teeth of young patients should be reconstructed bacause it can cause malocclusion, decreased masticatory efficiency, articulation disorders, esthetic problem, and temporomandibular disorder. Valplast$^{(R)}$(Valplast International Corp, New York, USA) flexible denture is useful for rehabilitation due to its excellent physical properties, esthetics, and small volume. This case is regardingan intellecturally disabled patient with anarticulation disorder caused by missing lower incisors due to trauma. The patient showed improvement in articulation by using flexible partial denture. The purpose of this report is to figure out the influence of missing lower anterior teeth on articulation.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

Full mouth Rehabilitation in a Patient with Occlusal Collapse with Vertical Dimension Increase (교합 붕괴 환자에서 수직 고경을 증가한 보철 수복 : 증례 보고)

  • Jo, Si-Hoon;Jeong, Su-Yang;Nam, Hyun-Seok;Song, Kwang-Yeob;Park, Ju-Mi;Ahn, Seung-Geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.477-482
    • /
    • 2010
  • In a case of multiple posterior teeth loss, antagonistic teeth extrude to the edentulous space and compensatory occlusion on the remained anterior teeth leads to occlusal trauma. Extrusion of antagonistic teeth breaks down occlusion plane and loss of posterior support bring about severe wear of remained teeth. In this situation, it is needed to restore remained teeth and edentulous space by increasing vertical dimension to obtain prosthodontic rehabilitation space and to correct occlusion plane. In this case report, the patient had a masticatory problem with loss of posterior teeth support and an esthetic problem of shortened anterior teeth. Before the tooth preparation for the prosthodontic restoration, the patient used removable device for 2 months to increase vertical dimension reversibly. After that, he got provisional fixed restoration with irreversible tooth reduction and used it for 3 months. It had spent 5 month to evaluate the adaptation state on final restoration with incresed vertical dimension. The increasing amount was 3 mm, which was relatively in less degree and masticatory system adapted to the increased vertical dimension without any pathologic changes. Final restoration was made to have equal-intensity contacts on all teeth in a verifiable centric relations and immediate disclusion of all posterior contacts the moment the mandible moves in any direction from centric relation. In addition, metal occlusion surface on posterior teeth was applied to prevent excessive muscle activation, occlusal trauma and the porcelain fracture.

A study on TPACK of mathematics teachers : Focusing on recognitions and educational needs of TPACK (수학교사의 테크놀로지 교수 내용 지식(TPACK)에 대한 연구 : TPACK에 대한 인식 및 교육요구도 분석 중심으로)

  • Lee, Da-Hee;Whang, Woo-Hyung
    • The Mathematical Education
    • /
    • v.57 no.1
    • /
    • pp.1-36
    • /
    • 2018
  • The purpose of this study is to examine the relationship between utilization of technology and TPACK in mathematics teachers, and to analyze needs and retentions, difference between needs and retentions, and educational needs of TPACK in mathematics teachers. Furthermore, we will prioritize TPACK items that mathematics teachers want to change, and provide implications for teacher education related to TPACK in the future. To do this, we analyzed 328 mathematics teachers nationwide by using survey on the utilization of technology, averages of TPACK's needs and retentions, t-test of two averages, Borich's educational needs analysis, and the Locus for Focus model. The results are as follows. Firstly, the actual utilization rate was lower than the positive recognition of utilization of technology by mathematics teachers, and many mathematics teachers mentioned the lack of knowledge related to TPACK. Secondly, the characteristics of in-service mathematics teacher's needs and retentions for TPACK were clear, and TPACK's starting line of in-service mathematics teacher can be different from pre-mathematics teacher's. The retentions was high in the order of CK, PCK and PK, and the needs was higher in the order of TPACK, TCK, TK and TPK. All of the higher retentions were knowledge related to PCK, and the value of CK was extremely high among them. In addition, mathematics teachers recognized needs for integrated knowledge related to technology, and they needed more TCK than TPK. The difference between needs and retentions showed that all items except two items in the PK were significant. Retentions of all items in CK was higher than needs, needs of all items in TK, TCK, TPK and TPACK was higher than retentions, PK and PCK were mixed. Thirdly, based on the analysis of Borich's educational needs and the Locus for Focus model, teacher education on TPACK for mathematics teachers needs to focus on TPACK, TK, TCK, and TPK. Specifically, TPACK needs to combine technology in terms of creativity-convergence, mathematical connections, communication, improvement of evaluation quality, and TK needs to new technology acquisition, function of utilizing technology, troubleshoot problems with technology, TCK needs to mathematical value(esthetic, practical) with technology, and TPK needs to consider technology in terms of evaluation methods, teaching and learning methods, improvement of pedagogy. Therefore, when determining the direction of teacher education related to TPACK in the future, if they try to reflect these items in detail, the teachers could participate more actively and receive practical help.

Effects of Surface Treatments of The Zirconium-Based Ceramic on the Bond Strength of Resin Cement (지르코니움 세라믹에서 표면 처리 방법이 레진 시멘트의 접착력에 미치는 영향)

  • Park, Kyung-Seok;Shin, Soo-Youn;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.221-230
    • /
    • 2006
  • Recently, the need for esthetic results has increased the interest for all-ceramic crown prosthesis. Furthermore, the development of zirconium core via CAD/CAM system has allowed the all ceramic restorations to be applied to almost all fixed prosthesis situations. But, the increased strength has been reported to increase in proportion with the bond strength of cement, and recently, the tribochemical system which increases the bond strength through, silica coating and silanization has been introduced. The purpose of this study was to compare the $Rocatec^{TM}$ system and $CoJet^{TM}$ system with the traditional acid etching and silanization method of the irconium based ceramic. The surface character was observed via SEM(X2000), and the bond strength with the resin cement were measured. 50 In-Ceram Zirconia (Adens, Korea) discs were fabricated and embedded in resin, group 1 was treated with glass-bead blasting and cleaning, group 2 was treated with 20% HF for 10 minutes and silanized, group 3 was treated with the $Rocatec^{TM}$ system, and group 4 was treated with the $CoJet^{TM}$ system. Each group was comprised of 10 specimens. The specimens were cemented to a $3mm{\times}5mm$ resin block with Super-Bond C&B. The shear bond strength was measured with the $Instron^{(R)}$ 8871 at a crosshead speed of 0.5mm/min. The results were as follows. 1. According to SEM results, there were little difference between group 1 & group 2, but in group 3 and 4, silica coating was detected and there was increase in surface roughness. 2. The shear bond strength decreased in the order of group 3(46.28MPa), group 4(42.04MPa), group 2(31.56MPa), and group 1(27.46MPa). 3. There was significant differnce between group 1&2 and group 3&4(p<0.05). From the results above, it can be considered that the conventional method of acid etching and silane treatment cannot increase the bond strength with resin cements, and that by applying the tribochemical system of $Rocatec^{TM}$ system and $CoJet^{TM}$ system, we can achieve a stronger all ceramic restoration. Further studies on surface treatments to increase the bond strength are thought to be needed.

The Diagnosis and Treatment of Bruxism (이갈이의 진단 및 치료)

  • Jeong-Seung, Kwon;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.87-101
    • /
    • 2012
  • Bruxism is extensively defined as a diurnal or nocturnal parafunctional habit of tooth clenching or grinding. The etiology of bruxism may be categorized as central factors or peripheral factors and according to previous research results, central factors are assumed to be the main cause. Bruxism may cause tooth attrition, cervical abfraction, masseter hypertrophy, masseter or temporalis muscle pain, temporomandibular joint arthralgia, trismus, tooth or restoration fracture, pulpitis, trauma from occlusion and clenching in particularly may cause linea alba, buccal mucosa or tongue ridging. An oral appliance, electromyogram or polysomnogram is used as a tool for diagnosis and the American Sleep Disorders Association has proposed a clinical criteria. However the exact etiology of bruxism is yet controversial and the selection of treatment should be done with caution. When the rate of bruxism is moderate or greater and is accompanied with clinical symptoms and signs, treatment such as control of dangerous factors, use of an oral appliance, botulinum toxin injection, pharmacologic therapy and biofeedback therapy may be considered. So far, oral appliance treatment is known to be the most rational choice for bruxism treatment. For patients in need of esthetic correction of hypertrophic masseters, as well as bruxism treatment, botulinum toxin injection may be a choice.

A study of illumination of dental laboratories (치과 기공실의 조명에 관한 실태 조사 연구)

  • Lee, Hyo-Jung;Choi, Jong-In;Kim, Sung-Sook;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.289-298
    • /
    • 2014
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental laboratories in order to distinguish colors for esthetic dentistry. Materials and Methods: A total of forty-eight local dental laboratories were selected for sampling a) luminous intensity and b) color temperature. We measured the luminous intensity and the color temperature on a center point of porcelain table with lux meter and color meter respectively. The measurements were performed twice, once on a clear day and on a cloudy day between 12 pm and 2 pm (day light and artificial illumination) and between 7 pm and 10 pm (artificial illumination only). Results: The results obtained were as follows. 1. The average luminous intensity in dental laboratories lighting was 1871 lx, and 67% of dental laboratories had luminous intensity greater than 1600 lx, which was appropriate for operations related to colors, while 33% of dental laboratories had in sufficient lighting for appropriate luminous intensity. 2. The average color temperature in dental laboratories lighting was 6506 K, which was inappropriate for operations related to color. None of the dental laboratories had a color temperature range of 5000 - 5500 K, which is appropriate for operations related to colors. 3. Between daytime and nighttime, also between clear day and cloudy day, the average luminous intensity and color temperature in dental laboratories were not significantly different. Conclusion: Illumination in most dental laboratories selected in this study was inappropriate for operations related to color.